AS-Interface cabling system - Schneider Electric
AS-Interface cabling system - Schneider Electric
AS-Interface cabling system - Schneider Electric
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Characteristics (continued) 0<strong>AS</strong>-<strong>Interface</strong><strong>cabling</strong> <strong>system</strong> 2Dedicated componentsEnclosed D.O.L. startersConnectionStarter type LF1, LF7 LF2, LF8Min. Max. Min. Max.Power supply<strong>cabling</strong>Motor <strong>cabling</strong>Auxiliary 24 Vsupply and outputcontrol relay<strong>cabling</strong>Screw clampterminalsCable gland(Pg 16)Screw clampterminalsCable gland(Pg 16)Solid cable mm 2 1x1.5 2x6 1x1.5 2x6Flexible cablemm 2 1x1.5 2x6 1x1.5 2x6without cable endFlexible cablemm 2 1x1.5 2x4 1x1.5 2x4with cable endTightening torque (1) N.m 1.7 1.7 1.7 1.7Clamping capacity mm 10 15 10 15Min. Max. Min. Max.Solid cable mm 2 1x1.5 2x4 1x1.5 1x4Flexible cablemm 2 1x1.5 2x4 1x1.5 1x4without cable endFlexible cablemm 2 1x1.5 1x1.5+1x2.5 1x1.5 1x2.5with cable endTightening torque (1) N.m 0.8 0.8 0.8 0.8Clamping capacity mm 10 15 10 15Min. Max. Min. Max.Terminal block Solid cable mm 2 0.5 1.5 0.5 1.5Flexible cablemm 2 0.5 1.5 0.5 1.5without cable endFlexible cablemm 2 0.5 1.5 0.5 1.5with cable endTightening torque (2) N.m 0.7 0.7 0.7 0.7Cable gland(included)Clamping capacity Pg 13 mm 8 13 8 13Pg 16 mm 10 15 10 152Pole electrical characteristicsUtilisation category Conforming to IEC 60947-2 A(circuit-breaker)Conforming to 947-4-1AC-3(motor starter)Rated operational voltage (Ue) Conforming to IEC 60947 V 415Rated insulation voltage (Ui) Conforming to IEC 60947 V 415Rated operational frequency Conforming to IEC 60947 Hz 50/60Breaking capacity(Ics and Icu)Sensitivity to phase failureConforming toIEC 60947-2Conforming toIEC 60947-4-1 § 7-2-1-5-2230/240 V kA >100400/415 V kA >100Circuit-breaker characteristics (manual operation)Mechanical durability C.O.: closing, opening C.O. 100 000<strong>Electric</strong>al durability In category AC-3 C.O. 100 000Service class Maximum operating rate C.O./h 25Circuit-breaker characteristics (automatic operation)Maximum operating rateIn operating cycles3600per hourMechanical durabilityIn millions of30 5operating cycles<strong>Electric</strong>al durability In category AC-3 to 8.5 A 800 000YesOther characteristicsStarters with rotary control knobStarters with pushbutton controlNon-reversing startersReversing startersCircuit-breaker typeSee our catalogue "Motor starter solutions"GV2 PCircuit-breaker typeSee our catalogue "Motor starter solutions"GV2 ME - LF1, LF2 onlyContactorSee our catalogue "Motor starter solutions"LP4 K09015BW3Reversing contactorSee our catalogue "Motor starter solutions"LP5 K09015BW3(1) Philips n° 2 or flat screwdriver Ø 5.5.(2) Flat screwdriver Ø 3.5.Functions :pages 2/18 to 2/21References :pages 2/26 to 2/29Dimensions, schemes :pages 2/34 to 2/41Connections :pages 2/32 and 2/332/23