11.07.2015 Views

AS-Interface cabling system - Schneider Electric

AS-Interface cabling system - Schneider Electric

AS-Interface cabling system - Schneider Electric

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Characteristics (continued) 0<strong>AS</strong>-<strong>Interface</strong><strong>cabling</strong> <strong>system</strong> 2Dedicated componentsEnclosed D.O.L. startersConnectionStarter type LF1, LF7 LF2, LF8Min. Max. Min. Max.Power supply<strong>cabling</strong>Motor <strong>cabling</strong>Auxiliary 24 Vsupply and outputcontrol relay<strong>cabling</strong>Screw clampterminalsCable gland(Pg 16)Screw clampterminalsCable gland(Pg 16)Solid cable mm 2 1x1.5 2x6 1x1.5 2x6Flexible cablemm 2 1x1.5 2x6 1x1.5 2x6without cable endFlexible cablemm 2 1x1.5 2x4 1x1.5 2x4with cable endTightening torque (1) N.m 1.7 1.7 1.7 1.7Clamping capacity mm 10 15 10 15Min. Max. Min. Max.Solid cable mm 2 1x1.5 2x4 1x1.5 1x4Flexible cablemm 2 1x1.5 2x4 1x1.5 1x4without cable endFlexible cablemm 2 1x1.5 1x1.5+1x2.5 1x1.5 1x2.5with cable endTightening torque (1) N.m 0.8 0.8 0.8 0.8Clamping capacity mm 10 15 10 15Min. Max. Min. Max.Terminal block Solid cable mm 2 0.5 1.5 0.5 1.5Flexible cablemm 2 0.5 1.5 0.5 1.5without cable endFlexible cablemm 2 0.5 1.5 0.5 1.5with cable endTightening torque (2) N.m 0.7 0.7 0.7 0.7Cable gland(included)Clamping capacity Pg 13 mm 8 13 8 13Pg 16 mm 10 15 10 152Pole electrical characteristicsUtilisation category Conforming to IEC 60947-2 A(circuit-breaker)Conforming to 947-4-1AC-3(motor starter)Rated operational voltage (Ue) Conforming to IEC 60947 V 415Rated insulation voltage (Ui) Conforming to IEC 60947 V 415Rated operational frequency Conforming to IEC 60947 Hz 50/60Breaking capacity(Ics and Icu)Sensitivity to phase failureConforming toIEC 60947-2Conforming toIEC 60947-4-1 § 7-2-1-5-2230/240 V kA >100400/415 V kA >100Circuit-breaker characteristics (manual operation)Mechanical durability C.O.: closing, opening C.O. 100 000<strong>Electric</strong>al durability In category AC-3 C.O. 100 000Service class Maximum operating rate C.O./h 25Circuit-breaker characteristics (automatic operation)Maximum operating rateIn operating cycles3600per hourMechanical durabilityIn millions of30 5operating cycles<strong>Electric</strong>al durability In category AC-3 to 8.5 A 800 000YesOther characteristicsStarters with rotary control knobStarters with pushbutton controlNon-reversing startersReversing startersCircuit-breaker typeSee our catalogue "Motor starter solutions"GV2 PCircuit-breaker typeSee our catalogue "Motor starter solutions"GV2 ME - LF1, LF2 onlyContactorSee our catalogue "Motor starter solutions"LP4 K09015BW3Reversing contactorSee our catalogue "Motor starter solutions"LP5 K09015BW3(1) Philips n° 2 or flat screwdriver Ø 5.5.(2) Flat screwdriver Ø 3.5.Functions :pages 2/18 to 2/21References :pages 2/26 to 2/29Dimensions, schemes :pages 2/34 to 2/41Connections :pages 2/32 and 2/332/23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!