11.07.2015 Views

AS-Interface cabling system - Schneider Electric

AS-Interface cabling system - Schneider Electric

AS-Interface cabling system - Schneider Electric

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Characteristics 2<strong>AS</strong>-<strong>Interface</strong><strong>cabling</strong> <strong>system</strong> 2Dedicated componentsEnclosed D.O.L. startersEnvironmentStarter type LF1, LF2 LF7, LF8Conforming to standards IEC 60204-1, EN 60204-1,–IEC 60439-1, IEC 60947-4-1,EN 60947-4-1UL 508, CSA C22-2 n° 14 (1)Product certifications <strong>AS</strong>-<strong>Interface</strong> pending <strong>AS</strong>-<strong>Interface</strong> N° 186012Protective treatment Standard version “TC” “TH”Degree of protectionconforming to IEC 60529Ambient air temperaturearound the deviceconforming to IEC 60439-1Starters with rotary control knob IP 55 IP 55Starters with pushbutton control IP 65 –Storage °C -40…+80 - 40…+ 85Operation °C -5…+40 - 10…+ 40Maximum operating altitude Without derating m 2000Operating positionswithout deratingIn relation to normalvertical mounting plane30°30°90°90°Flame resistanceConforming to IEC 60695-2-1 °C 960of equipmentShock resistanceContactor open10 gn(1/2 sine wave, 11 ms)conforming to IEC 60068-2-27Contactor closed15 gnVibration resistanceContactor open2gn5…150 Hzconforming to IEC 60068-2-6Contactor closed4gnSafe separation of circuits Conforming to VDE 0106and IEC 60536SELV (Safety Extra Low Voltage), up to 400 VImmunity to non-dissipatingshockwave (Uimp)Material and colourof enclosure baseMaterial and colourof enclosure coverConforming to IEC 60947-1 kV 6: power2.5: <strong>AS</strong>-<strong>Interface</strong>, 24 V and sensorInsulated enclosures6: power2: <strong>AS</strong>-<strong>Interface</strong>, 24 V and sensorPolycarbonate impregnated with 20 % glass fibre, black throughoutMetal enclosures Sheet steel, RAL 7032 –Insulated enclosuresPolycarbonate impregnated with 20% glass fibre, grey RAL 7032 throughoutMetal enclosures Sheet steel, RAL 7032 –Resistance tochemical agentsInsulated enclosuresAvoid allowing this material to come into contact with: strong bases (certaindetergents), aromatic hydrocarbons, alcohol, chlorine solvents, ketones.Electromagnetic compatibilityImmunity toelectrostatic dischargeImmunity tofast transient currentsImmunity todissipated shock waveImmunity to conductedradio-frequency disturbanceImmunity to radiatedradio-frequency disturbanceRadio-conducted andradio-radiated rejectionConforming to IEC 61000-4-2EN 61000-4-2Conforming to IEC 61000-4-4EN 61000-4-4Conforming to IEC 61000-4-5EN 61000-4-5Conforming to IEC 61000-4-6ENV 50 141Conforming to IEC 61000-4-3ENV 50 140 and ENV 50 204(GSM)kV 8: in open air (level 3)4: in indirect mode (level 2)kV 2: power, <strong>AS</strong>-<strong>Interface</strong>, 24 V and sensor(level 3)kV 4/2: power (level 4)2/0.5: <strong>AS</strong>-<strong>Interface</strong>, 24 V and sensor(level 2)V/m 10V/m 10ENV 55 011/CISPR11 (G1) Class B Class A2: <strong>AS</strong>-<strong>Interface</strong>, 24 V and oninputs/outputs2: <strong>AS</strong>-<strong>Interface</strong>, 24 V and oninputs/outputs(1) Only for metal enclosures with letter U at the end of the reference.Functions :pages 2/18 to 2/21References :pages 2/26 to 2/29Dimensions, schemes :pages 2/34 to 2/41Connections :pages 2/32 and 2/332/22

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!