11.07.2015 Views

AS-Interface cabling system - Schneider Electric

AS-Interface cabling system - Schneider Electric

AS-Interface cabling system - Schneider Electric

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Dimensions 1<strong>AS</strong>-<strong>Interface</strong><strong>cabling</strong> <strong>system</strong> 1Advantys, interfaces for generic productsIP 67 I/O, <strong>AS</strong>-<strong>Interface</strong> V2.11Assembled products (direct connection modules)4-channel interfaces with connection base <strong>AS</strong>I 67FFB01Can be mounted on 35 mm 5 rail.4-channel interfaces with connectionbase <strong>AS</strong>I 67FFB028-channel interfaces with connection base<strong>AS</strong>I 67FFB0360= =42457116,5Ø345= =107 515134 40,5807 66(1)4,5(1)724,57 31 7Monobloc products (remote connection modules)4-channel interfaces37,5(1) 2 elongated holes Ø 4.6 x 3. (1) 2 elongated holes Ø 4.6 x 3.8-channel interfaces3 33 330,510,5 33 10,560116,5Ø345= =107 5151= =34 40,5(1)(1)724,54,547,53 33 34010,5 33 10,5(1) 2 elongated holes Ø 4.6 x 3. (1) 2 elongated holes Ø 4.6 x 3.Explanation of LEDs4-channel interfaces8 channel interfaces1 I/O LED1 I/O LED2 341I/O ON:, I/O OFF:2 <strong>AS</strong>-<strong>Interface</strong> power On LED (<strong>AS</strong>I PWR)3 Fault LED4 AUX power On LED (AUX PWR)1234I/O ON: , I/O OF :2 <strong>AS</strong>-<strong>Interface</strong> power On LED (<strong>AS</strong>I PWR)3 Fault LED4 AUX power On LED (AUX PWR)Status <strong>AS</strong>I PWR Fault AUX PWROffPower off or reversed polarityon the <strong>AS</strong>-<strong>Interface</strong> lineOK (1)Power off or reversed polarity on the AUX line(4)ON OK No communication (2) OK (4)Flashing – Peripheral fault (3) –(1) No fault indication if power off or reversed polarity on the <strong>AS</strong>-<strong>Interface</strong> line.(2) Master in STOP condition, incorrect IO/ID configuration, Slave at address 0.(3) Sensor supply or output overload, undervoltage or reversed polarity on AUX line, only for <strong>AS</strong>I 67FpPppD/<strong>AS</strong>I 67FpPppE.(4) LED not working on <strong>AS</strong>I 67FpP40pp.Presentation, description :page 1/18Setting-up :pages 1/19 and 1/20Characteristics :pages 1/21 and 1/22References :pages 1/23 to 1/25Schemes, connections :pages 1/27 to 1/301/26

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!