11.07.2015 Views

AS-Interface cabling system - Schneider Electric

AS-Interface cabling system - Schneider Electric

AS-Interface cabling system - Schneider Electric

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Characteristics (continued) 1<strong>AS</strong>-<strong>Interface</strong><strong>cabling</strong> <strong>system</strong> 1Advantys, interfaces for generic productsIP 67 I/O, <strong>AS</strong>-<strong>Interface</strong> V2.11Characteristics of V2.1 compatible interfaces<strong>Interface</strong> type <strong>AS</strong>I 67FpP40D <strong>AS</strong>I 67FpP22D <strong>AS</strong>I 67FpP04D <strong>AS</strong>I 67FpP44D/44DY<strong>AS</strong>-<strong>Interface</strong> max. consumption without sensor supply (1) 45 mA 32 mA 19 mA 49 mA<strong>AS</strong>-<strong>Interface</strong> profile (I/O code, ID code, ID1, ID2) 00FE 30FE 80FE 70FE (<strong>AS</strong>I 67FpP44D)7FFE (<strong>AS</strong>I 67FpP44DY)<strong>AS</strong>-<strong>Interface</strong> certifications N° 55001 N° 55101 N° 55201 N° 55301(<strong>AS</strong>I 67FpP44D)pending (P44DY)Maximum number of addresses 31Number of data bits/number of I/O D0 I1 I1 O1 I1 or O1D1 I2 I2 O2 I2 or O2D2 I3 O3 O3 I3 or O3D3 I4 O4 O4 I4 or O4Input or output status data bit value D0 to D3 0 = input On / output Off. 1 = input / output OnOutput fallbackOff in the absence of communicationParameter bitsNot usedProduct status in the event of a peripheral faultThe interface is not inhibited. The peripheral fault bit is On and can be accessed by the master.Peripheral fault informationThe peripheral fault bit is On in the case of: - output overload or short-circuit, - absence ofauxiliary supply, - sensor supply overload (I > 200 mA).The interface is not inhibited.Characteristics of extended A/B addressing interfaces<strong>Interface</strong> type <strong>AS</strong>I 67FpP40E/40EY <strong>AS</strong>I 67FpP22E <strong>AS</strong>I 67FpP03E <strong>AS</strong>I 67FpP43E/43EY<strong>AS</strong>-<strong>Interface</strong> max. consumption without sensor supply (1) 45 mA 32 mA 18 mA 48 mA<strong>AS</strong>-<strong>Interface</strong> profile (I/O code, ID code, ID1, ID2)<strong>AS</strong>-<strong>Interface</strong> certification0A70 (<strong>AS</strong>I 67FpP40E)0A72 (<strong>AS</strong>I 67FpP40EY)n° 55001 (<strong>AS</strong>I 67FpP40E)pending (P40EY)BA70 8A70 7A70 (<strong>AS</strong>I 67FpP43E)7A7E (<strong>AS</strong>I 67FpP43EY)n° 55101 n° 55201 n° 55301 (<strong>AS</strong>I 67FpP43E)pending (P43EY)Maximum number of addresses 62Number of data bits/number of I/O D0 I1 O1 O1 I1 or O1D1 I2 O2 O2 I2 or O2D2 I3 I3 O3 I3 or O3D3 I4 I4 - ∆ (2) I4 ∆ (2)Input or output status data bit value D0 à D3 0 = input or output Off. 1 = input or output OnOutput fallbackOff in the absence of communicationParameter bitsNot usedProduct status in the event of a peripheral faultThe interface is not inhibited. The peripheral fault bit is On and can be accessed by the master.Peripheral fault informationThe peripheral fault bit is On in the case of: output overload or short-circuit, absence of auxiliarysupply, sensor supply overload (I > 200 mA).The interface is not inhibited.Input characteristics (sensor side)Sensor typePNP (2 and 3-wire)Supply voltage To IEC/EN 60947-5-1 V 18…30Maximum sensor supply current(3)Via the <strong>AS</strong>-<strong>Interface</strong>linemA 200 (for an operating temperature < 40 °C). 150 (for an operating temperaturebetween 40 °C and 70 °C). 100 for <strong>AS</strong>I 67FpP22pState 1 guaranteedU>11VandI>6m<strong>AS</strong>tate 0 guaranteedU

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!