11.07.2015 Views

AS-Interface cabling system - Schneider Electric

AS-Interface cabling system - Schneider Electric

AS-Interface cabling system - Schneider Electric

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Presentation,description 1<strong>AS</strong>-<strong>Interface</strong> <strong>cabling</strong> <strong>system</strong> 1Advantys, interfaces for generic productsIP 67 I/O, <strong>AS</strong>-<strong>Interface</strong> V2.111 12Presentation<strong>AS</strong>I 67F interfaces enable traditional sensors and actuators - in particular proximitysensors, photo-electric sensors and limit switches - to be connected to the<strong>AS</strong>-<strong>Interface</strong> <strong>cabling</strong> <strong>system</strong>.564407-24-M9Because of their IP 67 degree of protection, they can be mounted directly on themachine, as near as possible to the sensors and actuators.564405-19-M6231 1281291071123581211107Two types of housing are available:b A compact, 45 mm wide housing for 4-channel interfaces.b A flat, 60 mm wide housing for 8-channel interfaces.The sensors and actuators are connected to the interface by M12 connectors. The<strong>AS</strong>-<strong>Interface</strong> line and any external power supply are connected in one of thefollowing ways, depending on the model:b Directly to the ribbon cables via an Insulation Displacement Connector (IDC)(2 possible mounting positions).b By means of an M12 connector.Conforming to the <strong>AS</strong>-<strong>Interface</strong> V2.1 specification, they offer diagnostic functionsand are available, depending on the model, with standard addressing (up to31 Slaves per master) or with extended addressing (up to 62 Slaves per master).Specific "V1 compatible" versions allow replacement of previous XZS interfaces anduseinassociationwithV1masters.564408-19-M511058564406-24-M1 121294512 118 121191054The inputs are compatible with 2 and 3-wire sensors and with the majority of modelsin the Osiris, Osiprox and Osiswitch sensor ranges, with or without alarm output.Supply to the sensors (200 mA max) is via the <strong>AS</strong>-<strong>Interface</strong> line.The outputs, supplied by an external source, are of the 2 A transistor type.Description<strong>AS</strong>I 67F interfaces comprise:1 M12 connectors for connecting the sensors and actuators.2 Connector for yellow ribbon cable (<strong>AS</strong>-<strong>Interface</strong> line).3 Connector for black ribbon cable (auxiliary supply) - depending on model.4 M12 connectors for connecting the <strong>AS</strong>-<strong>Interface</strong> line and the auxiliary powersupply, also allowing connection for addressing via an <strong>AS</strong>I TERACC1Fconnection cable.5 Holes for fixing screws.6 Fitting for clipping onto 35 mm symmetrical rail.7 Jack connector for connection of an <strong>AS</strong>I TERACC2 cable for terminal <strong>AS</strong>I TERV2or XZ MC11.8 Diagnostic LED.9 I/O status LED.10Channel marker labels.11<strong>Interface</strong> marker label.12<strong>Interface</strong> to connection base fixing screws.Setting-up :pages 1/19 and 1/20Characteristics :pages 1/21 and 1/22References :pages 1/23 to 1/25Dimensions :page 1/26Schemes, connections :pages 1/27 to 1/301/18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!