96 en | Control Panel Programming Fire Alarm Control Panels3 Point is at an illegal address The addresses at which multi-address devicescan be installed are restricted.4 Too many multiplex relays Only 20 input output devices can be supportedon a given bus.Table 8.7: Auto programming error messagesFor details on installation restrictions, see also the specific device’s installation instructionsWhen the point adding operation completes, the FPD‐7024 shows for five seconds the totalnumber of points that were added to the control panel. Confirm that the number of devicesadded matches the expected number.AUTO PROGRAMxxx POINTS ADDED!Warning!Undetected devices!If a new device is not detected on the bus during the point adding operation, the device doesnot operate and does not generate trouble conditions even if it remains connected to the bus.When the point adding operation completes, the display shows the total number of points onthe system:AUTO PROGRAMxxx MUX POINTNote that xxx is the total number of points, not devices.Confirm that the system shows the exact number of points expected. Points that are notincluded in the total count do not operate and do not generate trouble conditions.After the count of total points appears for approximately 10 sec, the FPD‐7024 restores themultiplex system to normal operation. This process takes approximately 50 sec and thefollowing message appears during the restoral process:AUTO PROGRAMRESTORINGPLEASE WAIT...!Warning!Test for proper operation!As with any programming change to a system, test the system for proper operation before returningit to service. At least test each added multiplex point after auto programming completes.Test according to NFPA 72.8.9.5Removing MUX DevicesShortcut: 0-PROG, 9-PROGRAM MUX, 1- MUX EDITTo remove a previously programmed multiplex device, use the MUX Edit feature.2012.08 | 04 | F01U008458 Installation and Operation Manual Bosch Security System, Inc.
Fire Alarm Control Panels Control Panel Programming | en 97PROGRAM MUX1- MUX EDIT2- MUX PROGRAM3- BUS TYPE4- AUTO PROGRAMFrom the Program MUX menu, press [1] to select MUX Edit. The following window appears:DEVICE TYPE ( )0- NO DEVICE2- SINGLE INPUT3- I/O MODULE4- MUX SMOKE5- SMOKE W/FRZ6- DUAL INPUT7- OCTAL INPUTDescription Model0- NO DEVICE2- SINGLE INPUT D7044/M, D7045, FMM-7045, D7052(ClassA)3- I/O MODULE D70534- MUX SMOKE D7050, D7050TH, D3435- SMOKE W/FRZ Not Used6- DUAL INPUT D7052(Class B)7- OCTAL INPUT D7042Press [0/Prog] for No Device. Then enter the address for the point you wish to delete.After the device is successfully deleted, you return to the Device Type (MUX Edit) sub-menu.An unsuccessful deletion results in an error message (see below) followed by the Device Type(MUX Edit) sub-menu.ERROR –DEVICE FAILED!Warning!Dual point removal!If you remove one point of a dual point address (for example, a D7042 Eight Point Input Module),the second point (and subsequent points) at this address are also removed. For example,if the first point of a D7042 is removed, the remaining seven points are also removed.Bosch Security System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458
- Page 46 and 47: 46 en | System Operation Fire Alarm
- Page 48 and 49: 48 en | System Operation Fire Alarm
- Page 50 and 51: 50 en | Programming Fire Alarm Cont
- Page 52 and 53: 52 en | Programming Fire Alarm Cont
- Page 54 and 55: 54 en | Programming Fire Alarm Cont
- Page 56 and 57: 56 en | Programming Fire Alarm Cont
- Page 58 and 59: 58 en | Programming Fire Alarm Cont
- Page 60 and 61: 60 en | Control Panel Programming F
- Page 62 and 63: 62 en | Control Panel Programming F
- Page 64 and 65: 64 en | Control Panel Programming F
- Page 66 and 67: 66 en | Control Panel Programming F
- Page 68 and 69: 68 en | Control Panel Programming F
- Page 70 and 71: 70 en | Control Panel Programming F
- Page 72 and 73: 72 en | Control Panel Programming F
- Page 74 and 75: 74 en | Control Panel Programming F
- Page 76 and 77: 76 en | Control Panel Programming F
- Page 78 and 79: 78 en | Control Panel Programming F
- Page 80 and 81: 80 en | Control Panel Programming F
- Page 82 and 83: 82 en | Control Panel Programming F
- Page 84 and 85: 84 en | Control Panel Programming F
- Page 86 and 87: 86 en | Control Panel Programming F
- Page 88 and 89: 88 en | Control Panel Programming F
- Page 90 and 91: 90 en | Control Panel Programming F
- Page 92 and 93: 92 en | Control Panel Programming F
- Page 94 and 95: 94 en | Control Panel Programming F
- Page 98 and 99: 98 en | Specifications Fire Alarm C
- Page 101 and 102: Fire Alarm Control Panels Appendice
- Page 103 and 104: Fire Alarm Control Panels Appendice
- Page 105 and 106: Fire Alarm Control Panels Appendice
- Page 107: Fire Alarm Control Panels Appendice
- Page 110 and 111: 110 en | Appendices Fire Alarm Cont
- Page 112 and 113: 112 en | Appendices Fire Alarm Cont
- Page 114 and 115: 114 en | Appendices Fire Alarm Cont
- Page 116 and 117: 116 en | Appendices Fire Alarm Cont
- Page 118 and 119: 118 en | Appendices Fire Alarm Cont
- Page 122: Bosch Security Systems, Inc.130 Per
96 en | <strong>Control</strong> Panel Programming <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong>3 Point is at an illegal address The addresses at which multi-address devicescan be installed are restricted.4 Too many multiplex relays Only 20 input output devices can be supportedon a given bus.Table 8.7: Auto programming error messagesFor details on installation restrictions, see also the specific device’s installation instructionsWhen the point adding operation completes, the FPD‐7024 shows for five seconds the totalnumber of points that were added to the control panel. Confirm that the number of devicesadded matches the expected number.AUTO PROGRAMxxx POINTS ADDED!Warning!Undetected devices!If a new device is not detected on the bus during the point adding operation, the device doesnot operate and does not generate trouble conditions even if it remains connected to the bus.When the point adding operation completes, the display shows the total number of points onthe system:AUTO PROGRAMxxx MUX POINTNote that xxx is the total number of points, not devices.Confirm that the system shows the exact number of points expected. Points that are notincluded in the total count do not operate and do not generate trouble conditions.After the count of total points appears for approximately 10 sec, the FPD‐7024 restores themultiplex system to normal operation. This process takes approximately 50 sec and thefollowing message appears during the restoral process:AUTO PROGRAMRESTORINGPLEASE WAIT...!Warning!Test for proper operation!As with any programming change to a system, test the system for proper operation before returningit to service. At least test each added multiplex point after auto programming completes.Test according to NFPA 72.8.9.5Removing MUX DevicesShortcut: 0-PROG, 9-PROGRAM MUX, 1- MUX EDITTo remove a previously programmed multiplex device, use the MUX Edit feature.2012.08 | 04 | F01U008458 Installation and Operation Manual <strong>Bosch</strong> <strong>Security</strong> System, Inc.