11.07.2015 Views

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> <strong>Control</strong> Panel Programming | en 89Enter the number of history records you wish to delete, and press [#/Enter]. The previousmenu appears.8.8.2Default EE!Warning!Lost programming!All programming, including zone configurations and option installations, are lost when this operationis performed. You must turn control panel power off and on after resetting the default,to reinstall the four zone expanders and the MUX expander. You must update the optionbus and set up keypads (PROG SYSTEM MENU) to reinstall option bus devices.Shortcut: 0-PROG, 8-HSTRY DEFLTS, 2- DEFAULT EEYou can set the control panel back to the original factory-programming configuration with thisoption. You are asked to press [#/Enter] to complete the operation. Press [*/Back] to cancelthe operation.The following window appears:SETTING EEPROMTO DEFAULT...When the operation is complete, the previous menu appears. This operation takes severalminutes when the D7039 Multiplex Expander is installed.8.8.3Alternate 4/2 CodesShortcut: 0-PROG, 8-HSTRY DEFLTS, 3- ALT 4/2 CDESYou can set all of the programming for 4/2 codes to an alternative set of default reports, asdescribed in Appendix D, 110. To cause a complete control panel default, use the default EEoption.The following window appears:SETTING EEPROMTO DEFAULT...When the operation is complete, the previous menu appears.8.9Program MUXShortcut: 0-PROG, 9-PROGRAM MUX!iWarning!1. Unprogrammed devices on the bus will not operate or be supervised2. This menu is accessible only when the D7039 Multiplex expander is installed.3. Do not install more than one device programmed to the same address on the bus. Doing socan inhibit alarm reporting from both devices.Notice!Intermittent trouble reports from a particular MUX point address can indicate that more thanone device was programmed to that address.The following window appears:<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!