88 en | Control Panel Programming Fire Alarm Control PanelsSYSTM IN TST ( )0 THRU 9: A: B: C: D: E: FEnter digits that correspond to the selected condition by pressing a number key, or one of thespecial keys if a hex character is needed. Press [#/Enter] and the previous display appears.8.7.3BFSK Report CodesShortcut: 0-PROG, 7-PROG FORMATS, 1-BFSK RPT CODSWhen BFSK reporting is used, most reporting codes are fixed and do not need programming.There are five reports that the control panel can send that are not standard BFSK codes:Off normal at test: Sent if the panel is off-normal at the automatic test time.Open reset report: Sent when the reset key is pressed.Silence: Sent when the silence key is pressed.Fire drill, fire drill restore: Sent for fire drill operations.The following window displays:BFSK RPT CDS1- OFF NORM TEST2- OPEN/RESET3- SILENCE4- FIRE DRILL5- FR DRIL RSTRPress the number key that corresponds to your report code selection. A window allowingentry of two hex digits appears.8.8HISTORY DEFAULTSShortcut: 0-PROG, 8-HSTRY DEFLTSThe following window appears:PROG DEFAULTS1- CLEAR HSTRY2- DEFAULT EE3- ALT 4/2 CDES4- (reserved)8.8.1Clear HistoryShortcut: 0-PROG, 8-HSTRY DEFLTS, 1- CLEAR HISTORYYou can use this option to clear some or all of the history records in the system.The following window appears:HIST ITEMS= _______DEL OLDEST 0002012.08 | 04 | F01U008458 Installation and Operation Manual Bosch Security System, Inc.
Fire Alarm Control Panels Control Panel Programming | en 89Enter the number of history records you wish to delete, and press [#/Enter]. The previousmenu appears.8.8.2Default EE!Warning!Lost programming!All programming, including zone configurations and option installations, are lost when this operationis performed. You must turn control panel power off and on after resetting the default,to reinstall the four zone expanders and the MUX expander. You must update the optionbus and set up keypads (PROG SYSTEM MENU) to reinstall option bus devices.Shortcut: 0-PROG, 8-HSTRY DEFLTS, 2- DEFAULT EEYou can set the control panel back to the original factory-programming configuration with thisoption. You are asked to press [#/Enter] to complete the operation. Press [*/Back] to cancelthe operation.The following window appears:SETTING EEPROMTO DEFAULT...When the operation is complete, the previous menu appears. This operation takes severalminutes when the D7039 Multiplex Expander is installed.8.8.3Alternate 4/2 CodesShortcut: 0-PROG, 8-HSTRY DEFLTS, 3- ALT 4/2 CDESYou can set all of the programming for 4/2 codes to an alternative set of default reports, asdescribed in Appendix D, 110. To cause a complete control panel default, use the default EEoption.The following window appears:SETTING EEPROMTO DEFAULT...When the operation is complete, the previous menu appears.8.9Program MUXShortcut: 0-PROG, 9-PROGRAM MUX!iWarning!1. Unprogrammed devices on the bus will not operate or be supervised2. This menu is accessible only when the D7039 Multiplex expander is installed.3. Do not install more than one device programmed to the same address on the bus. Doing socan inhibit alarm reporting from both devices.Notice!Intermittent trouble reports from a particular MUX point address can indicate that more thanone device was programmed to that address.The following window appears:Bosch Security System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458
- Page 38 and 39: 38 en | System Operation Fire Alarm
- Page 40 and 41: 40 en | System Operation Fire Alarm
- Page 42 and 43: 42 en | System Operation Fire Alarm
- Page 44 and 45: 44 en | System Operation Fire Alarm
- Page 46 and 47: 46 en | System Operation Fire Alarm
- Page 48 and 49: 48 en | System Operation Fire Alarm
- Page 50 and 51: 50 en | Programming Fire Alarm Cont
- Page 52 and 53: 52 en | Programming Fire Alarm Cont
- Page 54 and 55: 54 en | Programming Fire Alarm Cont
- Page 56 and 57: 56 en | Programming Fire Alarm Cont
- Page 58 and 59: 58 en | Programming Fire Alarm Cont
- Page 60 and 61: 60 en | Control Panel Programming F
- Page 62 and 63: 62 en | Control Panel Programming F
- Page 64 and 65: 64 en | Control Panel Programming F
- Page 66 and 67: 66 en | Control Panel Programming F
- Page 68 and 69: 68 en | Control Panel Programming F
- Page 70 and 71: 70 en | Control Panel Programming F
- Page 72 and 73: 72 en | Control Panel Programming F
- Page 74 and 75: 74 en | Control Panel Programming F
- Page 76 and 77: 76 en | Control Panel Programming F
- Page 78 and 79: 78 en | Control Panel Programming F
- Page 80 and 81: 80 en | Control Panel Programming F
- Page 82 and 83: 82 en | Control Panel Programming F
- Page 84 and 85: 84 en | Control Panel Programming F
- Page 86 and 87: 86 en | Control Panel Programming F
- Page 90 and 91: 90 en | Control Panel Programming F
- Page 92 and 93: 92 en | Control Panel Programming F
- Page 94 and 95: 94 en | Control Panel Programming F
- Page 96 and 97: 96 en | Control Panel Programming F
- Page 98 and 99: 98 en | Specifications Fire Alarm C
- Page 101 and 102: Fire Alarm Control Panels Appendice
- Page 103 and 104: Fire Alarm Control Panels Appendice
- Page 105 and 106: Fire Alarm Control Panels Appendice
- Page 107: Fire Alarm Control Panels Appendice
- Page 110 and 111: 110 en | Appendices Fire Alarm Cont
- Page 112 and 113: 112 en | Appendices Fire Alarm Cont
- Page 114 and 115: 114 en | Appendices Fire Alarm Cont
- Page 116 and 117: 116 en | Appendices Fire Alarm Cont
- Page 118 and 119: 118 en | Appendices Fire Alarm Cont
- Page 122: Bosch Security Systems, Inc.130 Per
88 en | <strong>Control</strong> Panel Programming <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong>SYSTM IN TST ( )0 THRU 9: A: B: C: D: E: FEnter digits that correspond to the selected condition by pressing a number key, or one of thespecial keys if a hex character is needed. Press [#/Enter] and the previous display appears.8.7.3BFSK Report CodesShortcut: 0-PROG, 7-PROG FORMATS, 1-BFSK RPT CODSWhen BFSK reporting is used, most reporting codes are fixed and do not need programming.There are five reports that the control panel can send that are not standard BFSK codes:Off normal at test: Sent if the panel is off-normal at the automatic test time.Open reset report: Sent when the reset key is pressed.Silence: Sent when the silence key is pressed.<strong>Fire</strong> drill, fire drill restore: Sent for fire drill operations.The following window displays:BFSK RPT CDS1- OFF NORM TEST2- OPEN/RESET3- SILENCE4- FIRE DRILL5- FR DRIL RSTRPress the number key that corresponds to your report code selection. A window allowingentry of two hex digits appears.8.8HISTORY DEFAULTSShortcut: 0-PROG, 8-HSTRY DEFLTSThe following window appears:PROG DEFAULTS1- CLEAR HSTRY2- DEFAULT EE3- ALT 4/2 CDES4- (reserved)8.8.1Clear HistoryShortcut: 0-PROG, 8-HSTRY DEFLTS, 1- CLEAR HISTORYYou can use this option to clear some or all of the history records in the system.The following window appears:HIST ITEMS= _______DEL OLDEST 0002012.08 | 04 | F01U008458 Installation and Operation Manual <strong>Bosch</strong> <strong>Security</strong> System, Inc.