11.07.2015 Views

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> <strong>Control</strong> Panel Programming | en 83PHONE CONTROL #11- MONITOR LINE2- DIALING TYPEFor explanations of the phone control options, see the following sections for Monitor Line andDialing Type.Monitor LineShortcut: 0-PROG, 6-PROG ACC’NTS, 2-PHONE CONTROLThe phone line monitor feature, that supervises the connection of the phone line to thecontrol panel, can be disabled for each phone line. If an IP address is entered for the Phone/IP number, set the monitor to No. If this is not programmed to No, a trouble is generated.Choose Line 1 or Line 2 (see the window above). The display scrolls through the Phone<strong>Control</strong> options. Press [1] for MONITOR LINE. The following window appears:MONITOR LINE #1_______: YES (1) NO (0)For acceptable programming selections for UL864 9 th edition Listed applications, seeProgramming features for UL864, 49.Press [1] for YES or [0/Prog] for NO. The previous window appears.Dialing TypeShortcut: 0-PROG, 6-PROG ACC’NTS, 2-PHONE CONTROLThis feature determines the format the control panel uses for dialing on each phone line. TheTONE/PULSE setting first tries tone dialing. If that fails, it switches to pulse dialing. If an IPaddress is entered in for the Phone/IP number, the control panel ignores this setting.Choose Line 1 or Line 2 (see the window below). The display scrolls through the Phone<strong>Control</strong> options. Press [2] for DIALING TYPE. The following window appears:PHONE CONTRO (__)1- PULSE ONLY2- TONE/PULSE3- TONE ONLYPress the number key that corresponds to your selection. The previous window appears.8.6.3Report SteeringShortcut: 0-PROG, 6-PROG ACC’NTS, 3-RPT STEERINGDifferent classes of reports can be directed to different phone numbers. Non-supervisoryalarms include fire alarms and waterflow alarms. Supervisory alarms come from pointsconfigured as a supervisory type. Non-supervisory restorals include fire and waterflowrestorals. Supervisory restorals come only from points configured as a supervisory type.Trouble reports include all point and system troubles and restorals. Tests include Auto Tests,Manual Tests and Off-normal at Test Reports. The control panel allows the special reportsSilence, Reset, and Drill to be individually directed.<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!