74 en | <strong>Control</strong> Panel Programming <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong>NAC CONFIG ( )1- STEADY2- PULSING3- CALIFORNIA MARCH4- TEMPORAL5- WHEELOCK6- GENTEX7- SYSTEM SENSORFor acceptable programming selections for UL864 9 th edition Listed applications, seeProgramming features for UL864, 49.These selections control the pattern (code) for the selected NAC. Press the number key thatcorresponds with the desired pattern:– Steady: Output turns on and stays on while the NAC is active.– Pulsing: Output turns on for 0.5 sec and off for 0.5 sec.– California March: Output turns on for 0.25 sec and off for 0.25 sec.– Temporal: Output turns on and off to implement the ANSI standard evacuation pattern(Temporal code 3).– Wheelock: Output is configured to support Wheelock devices with synchronizationcapability, including the ability to silence the horn of a combination horn strobe. TheWheelock configuration is not supported by remote NACs implemented using a RemoteNAC power supply.– Gentex: Output is configured to support Gentex devices with synchronization capability,including the ability to silence the horn of a horn strobe combination.iNotice!The Gentex option does not synchronize to the UL864 9th Edition standard.– System Sensor: Output is configured to support System Sensor devices withsynchronization capability, including the ability to silence the horn of a horn strobecombination.After you program the desired pattern configuration, the previous window appears.If you select 3 from the PROG NACs menu, you are asked to enter four zones to activate thisoutput.OUTPUT ZONE A (XX)(00-63):iNotice!XX” indicates the existing setting for each of the four output zone settings.Enter the desired zone to activate this output and press [#/Enter]. You are asked to enter upto four zones (A, B, C, D). Enter 00 (or leave it set at “00”) for any unused zones to preventunintentional output activation. After all four zones are programmed, the previous windowappears.For a list of pre-assigned zones, see the following table:2012.08 | 04 | F01U008458 Installation and Operation Manual <strong>Bosch</strong> <strong>Security</strong> System, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!