<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> <strong>Control</strong> Panel Programming | en 71– AC Fault: When activating, the control panel waits for the AC Delay Timer to expirebefore indicating or sending a trouble condition. When the timer expires, it shows an ACFault on the control panel and the trouble LED turns on.Enter the point number you wish to program and press [#/Enter]. The display scrolls throughthe PROG FUNCTION options.Press [0/Prog] to select CONFIGURE. The following window appears:ACTVTN TYPE ( )1- FIRE2- WATERFLOW3-SUPERVISORY4- (reserved)5- RESET6- SILENCE7- AC FAULTPress the number key that corresponds to your selection. (The existing setting is shown inparentheses on the first line.) The previous window appears.Local onlyShortcut: 0-PROG, 4-PROG INPUTS, 2-POINT FUNCTIONEnabling this feature provides the input point for local annunciation only, with nocommunicator report. Enter the point number you wish to program and press [#/Enter]. Thedisplay scrolls through the PROG FUNCTION options.Press [1] to select LOCAL ONLY. The following window appears:LOCAL ONLY_______: YES (1)NO(0)Press either [1] to enable or [0/Prog] to disable. The previous window appears.SilencingShortcut: 0-PROG, 4-PROG INPUTS, 2-POINT FUNCTIONThis feature determines if an output zone (1 to 50) follows the Silence button (relays reset,NACs silence).Enter the point number you wish to program and press [#/Enter]. The display scrolls throughthe PROG FUNCTION options.Press [3] to select SILENCEABLE. The following window appears:SILENCABLE? (FF)_______: YES (1)NO(0)Press [1] for relays to reset and NACs to silence when the Silence button is pressed, or press[0/Prog] for relays to remain latched until reset and NACs to continue sounding when theSilence button is pressed.iNotice!When an output is assigned to more than one zone, the programming of the zone that triggersthe output controls the output. When more than one zone triggers the output, if one of thezones is programmed as non-silencing, the output will be non-silencing.NOTICE!The previous window appears. FF indicates the function being programmed.<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!