<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> Programming | en 57The second level in your system provides eight options: PROG TIME, SECURITY,PROG SYSTEM, PROG INPUTS, PROG OUTPUTS, PROG ACCOUNTS, PROG FORMATS, andHISTORY DEFAULTS. When the D7039 MUX Expander is installed, a ninth option appears:PROGRAM MUX. The second number in the shortcut enters the Level 2 option and allowsaccess to Level 3.Level 3 provides the third set of options that branch from Level 2. The third number in theshortcut represents the option chosen in Level 3.For an example of the shortcut to TEST FREQ and TEST TIME, see the following figure. Thesample of the Program Menu Tree shows that to get to TEST TIME and TEST FREQ, you mustgo to PROG/0 in Level 1, PROG TIME in Level 2, and AUTO TEST in Level 3. The shortcut issimply a list of the keys you press to get to the fourth level option. Once you enter theshortcut, follow the procedural description that appears on the screen of the specific functionyou are programming.12Shortcut = 0123LEVEL 1(Main Menu)PROG/05LEVEL 2 LEVEL 3 LEVEL 41- SYSTEM1- PROG TIME1- TEST TIME2- AUTO TEST2- TEST FREQNCY4 6 78Figure 7.4: Example of a programming shortcut1 Use "0" to select PROG from the MainMenu which scrolls at the SystemNormal display.2 Use "1" to select PROG TIME fromSub-Level 2.3 Use "2" to select AUTO TEST from Sub-Level 3. Follow the proceduraldescription that appears on thescreen.5 Password6 Second number in shortcut7 Third number in shortcut4 First number in shortcut 8 Fourth number in shortcut7.7Remote programmingThe system operates during remote programming so that new alarms end the remoteprogramming session and report normally. Using the keypads to perform other functionsduring remote programming (such as tests and disables) can cause remote programming todisconnect or other unexpected operations. Avoid downloading programming changes thatcause alarms, because the session disconnects as soon as the alarm occurs, before thesession completes. To indicate that the system is in a special operating mode with user input<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!