46 en | System Operation Fire Alarm Control PanelsFigure 6.3: Mapping inputs, zones, and outputs1 Input Point 1 is assigned to Zone 1,mapped to NAC Point 1.2 Input Point 2 is assigned to Zone 2,mapped to NACs 1 and 2.3 Input Point 3 is assigned to Zone 2,mapped to NACs 1 and 2.4 Input Point 4 is assigned to Zone 2,mapped to NACs 1 and 2.5 Input Point 5 is assigned to Zone 3,mapped to NAC 2, LR 1 and RR1.6 General Alarm Zone 63 drives LR 2.For pre-assigned zone assignments, see the following table:ZoneCondition51 Reserved for future use.52 General Fire Alarm, Waterflow (non-silenceable). Same as Zone 53, but remainsactive even while system is silenced.53 General Fire Alarm (silenceable). Active when a fire alarm condition is present;does not activate for waterflow.54 Activates for approximately 7 sec before dialing, to initiate dial tone on a groundstart phone system.55 General Supervisory (silenceable)56 General Waterflow (silenceable)57 Communication Trouble. Active when the dialer fails to communicate; remainsactive until communication through the digital communicator is restored.58 General Supervisory Alarm (non-silenceable). Active when any supervisory alarmcondition is present.59 Alarm Verification. Active while alarm verification is in progress. This starts withthe first detection of an alarm to be verified and clears in two minutes, or whensystem is reset.60 No AC. Active when AC power fails.2012.08 | 04 | F01U008458 Installation and Operation Manual Bosch Security System, Inc.

Fire Alarm Control Panels System Operation | en 47ZoneCondition61 General Waterflow (Non-silenceable). Active when any waterflow alarm is present.62 General Trouble. Active while any system trouble is present, not active in test andprogramming modes.63 General Alarm, Waterflow (non-silenceable). Active while any alarm, includingsupervisory, is present. Remains active even while system is silenced.Table 6.3: Pre-assigned zones6.6Personal Identification Numbers (PINs)The personal identification number (PIN) is the four digit code users enter at the keypad togain access to the system. A PIN can be assigned to each User Number. The User Numberidentifies each person using the system. There are 16 possible User Numbers (00 to 15). Usercodes 00 to 99 are available with the installation of a D7039 Multiple Expansion Module. TheAuthority Level assigned to each User Number determines which functions each user canperform.Your system can have up to 100 different PINs, each four digits long. There is one PIN for eachUser Number. Attempting to assign the same PIN to multiple User Numbers results in thethree-beep error tone, and the change is not made.User Number 00 is designated as a Programmer’s Code. It can be used to silence alarms,reset, disable, and program the unit.User Number 00 is shipped from the factory with the sequence of 9876. Change this code toone of your personal preference. It is automatically assigned the highest authority. Neverprogram PINs with common sequences such as 1111, 1234, or 2468 because they are easilyviolated.Authority levels are assigned to PINs to determine which functions each user can perform.For a description of the four authority levels, see the following table:PIN authority levelMaximum (1)Medium (2)Minimum (3)None (0)Allowed operationsAll control panel operations, including programming, and disableSystem test modes, fire drill, reset, silence, view historySilence, view historyNoneTable 6.4: PIN authority levels6.7Communicator OperationThe FPD-7024 contains an integrated communicator that can be optionally enabled to sendreports to a monitoring station. When enabled, operation of the communicator is fullyautomatic.iNotice!You must enable and configure the communicator before it works. The communicator andphone line monitors are disabled in the default factory configuration.Bosch Security System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

46 en | System Operation <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong>Figure 6.3: Mapping inputs, zones, and outputs1 Input Point 1 is assigned to Zone 1,mapped to NAC Point 1.2 Input Point 2 is assigned to Zone 2,mapped to NACs 1 and 2.3 Input Point 3 is assigned to Zone 2,mapped to NACs 1 and 2.4 Input Point 4 is assigned to Zone 2,mapped to NACs 1 and 2.5 Input Point 5 is assigned to Zone 3,mapped to NAC 2, LR 1 and RR1.6 General <strong>Alarm</strong> Zone 63 drives LR 2.For pre-assigned zone assignments, see the following table:ZoneCondition51 Reserved for future use.52 General <strong>Fire</strong> <strong>Alarm</strong>, Waterflow (non-silenceable). Same as Zone 53, but remainsactive even while system is silenced.53 General <strong>Fire</strong> <strong>Alarm</strong> (silenceable). Active when a fire alarm condition is present;does not activate for waterflow.54 Activates for approximately 7 sec before dialing, to initiate dial tone on a groundstart phone system.55 General Supervisory (silenceable)56 General Waterflow (silenceable)57 Communication Trouble. Active when the dialer fails to communicate; remainsactive until communication through the digital communicator is restored.58 General Supervisory <strong>Alarm</strong> (non-silenceable). Active when any supervisory alarmcondition is present.59 <strong>Alarm</strong> Verification. Active while alarm verification is in progress. This starts withthe first detection of an alarm to be verified and clears in two minutes, or whensystem is reset.60 No AC. Active when AC power fails.2012.08 | 04 | F01U008458 Installation and Operation Manual <strong>Bosch</strong> <strong>Security</strong> System, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!