Fire Alarm Control Panels - Bosch Security Systems
Fire Alarm Control Panels - Bosch Security Systems Fire Alarm Control Panels - Bosch Security Systems
40 en | System Operation Fire Alarm Control PanelsFor additional history log ID information, see the Modem IIIa 2 reporting table, 105.6.2.9Remote ProgrammingCall for remote programmingPhone Numbers 1 and 3 must be programmed, along with Account Code 1. The control panelcalls Phone Number 3 and attempts to connect for downloading. If the control panel is alreadyusing the phone line, it sounds the three-beep error tone. This function requires an accesscode with programming authority (Level 1).Answer for remote programmingThe control panel immediately seizes the phone line to answer a remote programming call.While programming is underway, the Trouble LED flashes. This also allows on-site PCdownloading. If the control panel already uses the phone line for a report communication, itsounds the three-beep error tone. This function requires an access code with programmingauthority (Level 1).6.36.3.1KeypadsBuilt-in keypadThe keypad built into the control/communicator is an alphanumeric LCD keypad. It has a twolineby 16-character display to provide information on various control panel functions. Usually,the first line shows the off-normal condition, while the second line describes specific detailsthat might be relevant to the existing system status. A built-in sounder annunciates keystrokeentries and acts as a warning device.2012.08 | 04 | F01U008458 Installation and Operation Manual Bosch Security System, Inc.
Fire Alarm Control Panels System Operation | en 41Figure 6.1: Built-in Keypad1 Green Power LED - is on when the ACpower is present, and flashes whenthe unit is operating from batterypower.2 Yellow Trouble LED - lights when thesystem detects a problem with wiringor internal circuitry. The Trouble LEDflashes while programming mode isactive and whenever inputs are notactive, such as during smoke powerreset or alarm verification.3 Red Alarm LED - lights when thesystem registers an alarm and was notreset.9 [#/Enter] key - to accept data when inthe programming mode.10 [History] key - to view system events.11 [Reset] key - briefly (programmablefrom 1 to 16 seconds) turns off powerto the detectors to reset them andclears any off- normal conditions.Bosch Security System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458
- Page 6: MethodenberichtBerliner pairfam Stu
- Page 14 and 15: 14 en | Overview Fire Alarm Control
- Page 17 and 18: Fire Alarm Control Panels Overview
- Page 19 and 20: Fire Alarm Control Panels Overview
- Page 22 and 23: 22 en | Installation Fire Alarm Con
- Page 24 and 25: 24 en | Installation Fire Alarm Con
- Page 26 and 27: 26 en | Installation Fire Alarm Con
- Page 28 and 29: 28 en | Installation Fire Alarm Con
- Page 30 and 31: 30 en | Connection Fire Alarm Contr
- Page 32 and 33: 32 en | Connection Fire Alarm Contr
- Page 34 and 35: 34 en | Connection Fire Alarm Contr
- Page 36 and 37: 36 en | System Operation Fire Alarm
- Page 38 and 39: 38 en | System Operation Fire Alarm
- Page 42 and 43: 42 en | System Operation Fire Alarm
- Page 44 and 45: 44 en | System Operation Fire Alarm
- Page 46 and 47: 46 en | System Operation Fire Alarm
- Page 48 and 49: 48 en | System Operation Fire Alarm
- Page 50 and 51: 50 en | Programming Fire Alarm Cont
- Page 52 and 53: 52 en | Programming Fire Alarm Cont
- Page 54 and 55: 54 en | Programming Fire Alarm Cont
- Page 56 and 57: 56 en | Programming Fire Alarm Cont
- Page 58 and 59: 58 en | Programming Fire Alarm Cont
- Page 60 and 61: 60 en | Control Panel Programming F
- Page 62 and 63: 62 en | Control Panel Programming F
- Page 64 and 65: 64 en | Control Panel Programming F
- Page 66 and 67: 66 en | Control Panel Programming F
- Page 68 and 69: 68 en | Control Panel Programming F
- Page 70 and 71: 70 en | Control Panel Programming F
- Page 72 and 73: 72 en | Control Panel Programming F
- Page 74 and 75: 74 en | Control Panel Programming F
- Page 76 and 77: 76 en | Control Panel Programming F
- Page 78 and 79: 78 en | Control Panel Programming F
- Page 80 and 81: 80 en | Control Panel Programming F
- Page 82 and 83: 82 en | Control Panel Programming F
- Page 84 and 85: 84 en | Control Panel Programming F
- Page 86 and 87: 86 en | Control Panel Programming F
- Page 88 and 89: 88 en | Control Panel Programming F
<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> System Operation | en 41Figure 6.1: Built-in Keypad1 Green Power LED - is on when the ACpower is present, and flashes whenthe unit is operating from batterypower.2 Yellow Trouble LED - lights when thesystem detects a problem with wiringor internal circuitry. The Trouble LEDflashes while programming mode isactive and whenever inputs are notactive, such as during smoke powerreset or alarm verification.3 Red <strong>Alarm</strong> LED - lights when thesystem registers an alarm and was notreset.9 [#/Enter] key - to accept data when inthe programming mode.10 [History] key - to view system events.11 [Reset] key - briefly (programmablefrom 1 to 16 seconds) turns off powerto the detectors to reset them andclears any off- normal conditions.<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458