32 en | Connection Fire Alarm Control PanelsDX4020,B420 models,ITS-DX4020-GFigure 5.6: Keypad Connection (supervised, Class B, Style 4, 500 mA maximum)Figure 5.7: Backup Batteries1 Class B, Style Y supervised:2 Class A, Style Z BAT Battery3 Backup batteries BK blackEOL End of lineRD rediNotice!Unswitched unsupervised Auxiliary Power: 24 V, 1.0 A maximum (unfiltered).2012.08 | 04 | F01U008458 Installation and Operation Manual Bosch Security System, Inc.
Fire Alarm Control Panels Connection | en 33Danger!Explosion and burn hazard!Do not short terminals!Notification appliance circuit:NAC 1+NAC 1-+24 V while in alarm; ground while in standby.Ground while in alarm; supervisory voltage while in standby.Notification appliance circuit:NAC 2+NAC 2-+24 V while in alarm; ground while in standby.Ground while in alarm; supervisory voltage while in standby.Batteries:BAT -BAT +Requires two 12 V batteries in series, for a combined voltage of 24 V.Charge current = 1.1 A, maximumUse only indicating devices as listed on Technogram P/N. F01U010791.5.2Power supply connectionUse wire nuts to connect the primary side of the transformer in one of the following ways:– black and white wires to an unswitched 120 V, 60 Hz, or– yellow and white wires to an unswitched 240 V, 50 Hz circuit.Danger!Shock Risk!Do to risk of shock and/or damage to the transformer a wire mut must be in place over theunused black or yellow wire.Connect the earth ground to the threaded ground stud on the left side of the enclosure.Bosch Security System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458
- Page 6: MethodenberichtBerliner pairfam Stu
- Page 14 and 15: 14 en | Overview Fire Alarm Control
- Page 17 and 18: Fire Alarm Control Panels Overview
- Page 19 and 20: Fire Alarm Control Panels Overview
- Page 22 and 23: 22 en | Installation Fire Alarm Con
- Page 24 and 25: 24 en | Installation Fire Alarm Con
- Page 26 and 27: 26 en | Installation Fire Alarm Con
- Page 28 and 29: 28 en | Installation Fire Alarm Con
- Page 30 and 31: 30 en | Connection Fire Alarm Contr
- Page 34 and 35: 34 en | Connection Fire Alarm Contr
- Page 36 and 37: 36 en | System Operation Fire Alarm
- Page 38 and 39: 38 en | System Operation Fire Alarm
- Page 40 and 41: 40 en | System Operation Fire Alarm
- Page 42 and 43: 42 en | System Operation Fire Alarm
- Page 44 and 45: 44 en | System Operation Fire Alarm
- Page 46 and 47: 46 en | System Operation Fire Alarm
- Page 48 and 49: 48 en | System Operation Fire Alarm
- Page 50 and 51: 50 en | Programming Fire Alarm Cont
- Page 52 and 53: 52 en | Programming Fire Alarm Cont
- Page 54 and 55: 54 en | Programming Fire Alarm Cont
- Page 56 and 57: 56 en | Programming Fire Alarm Cont
- Page 58 and 59: 58 en | Programming Fire Alarm Cont
- Page 60 and 61: 60 en | Control Panel Programming F
- Page 62 and 63: 62 en | Control Panel Programming F
- Page 64 and 65: 64 en | Control Panel Programming F
- Page 66 and 67: 66 en | Control Panel Programming F
- Page 68 and 69: 68 en | Control Panel Programming F
- Page 70 and 71: 70 en | Control Panel Programming F
- Page 72 and 73: 72 en | Control Panel Programming F
- Page 74 and 75: 74 en | Control Panel Programming F
- Page 76 and 77: 76 en | Control Panel Programming F
- Page 78 and 79: 78 en | Control Panel Programming F
- Page 80 and 81: 80 en | Control Panel Programming F
32 en | Connection <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong>DX4020,B420 models,ITS-DX4020-GFigure 5.6: Keypad Connection (supervised, Class B, Style 4, 500 mA maximum)Figure 5.7: Backup Batteries1 Class B, Style Y supervised:2 Class A, Style Z BAT Battery3 Backup batteries BK blackEOL End of lineRD rediNotice!Unswitched unsupervised Auxiliary Power: 24 V, 1.0 A maximum (unfiltered).2012.08 | 04 | F01U008458 Installation and Operation Manual <strong>Bosch</strong> <strong>Security</strong> System, Inc.