Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems Fire Alarm Control Panels - Bosch Security Systems

boschsecurity.com
from boschsecurity.com More from this publisher
11.07.2015 Views

110 en | Appendices Fire Alarm Control PanelsConditionSystemeventConditionSystemeventNAC 2 shorted wiring 29 Remote NAC module 1, output 3disabled by user79Remote NAC module 1 ground faultshortRemote NAC module 2 ground faultshortRemote NAC module 3 ground faultshortRemote NAC module 4 ground faultshort30 Remote NAC module 1, output 4disabled by user31 Remote NAC module 2, output 1disabled by user32 Remote NAC module 2, output 2disabled by user33 Remote NAC module 2, output 3disabled by user80818283NAC 1 overcurrent 34 Remote NAC module 2, output 4disabled by userNAC 2 overcurrent 35 Remote NAC module 3, output 1disabled by userRemote NAC module 1 low battery 36 Remote NAC module 3, output 2disabled by userRemote NAC module 2 low battery 37 Remote NAC module 3, output 3disabled by userRemote NAC module 3 low battery 38 Remote NAC module 3, output 4disabled by userRemote NAC module 4 low battery 39 Remote NAC module 4, output 1disabled by userCommunication path IP #1 fault 40 Remote NAC module 4, output 2disabled by userMultiplex bus outputs disabled by user 46 Remote NAC module 4, output 3disabled by userDialer disabled by user 47 Remote NAC module 4, output 4disabled by user848586878889909192Relay 1 disabled by user 48 Four zone expander installation fault 93Relay 2 disabled by user 49 MUX (DS9341) expander installationfault94Relay 3 disabled by user 50 Communication path IP #2 fault 95Remote relay module 1 disabled by user 51Table 10.5: History log10.4Appendix D: Programming Defaults ListFor program default settings, see the following tables:2012.08 | 04 | F01U008458 Installation and Operation Manual Bosch Security System, Inc.

Fire Alarm Control Panels Appendices | en 111PROG TIMESYSTEM: Last date in EE 0000AUTO TESTTEST TIME: 0200TEST FREQ:DAYLIGHT SAV:3 hr to 24 hr2- enableSECURITYPINSPROGRAMMER: 9876USERS: User 1 = 1234User 2 = 0000AUTHORITYUSER 1: 2OTHERS: 0PROG SYSTEMTIMERSSMOKE RESET:AC FAIL DELAY:AUTO SILENCE:DISPLAY RATE:AC LINE SYNCH6 sec6 hr0 min4x.25 = 1 sec2 (60 Hz)OPTION BUSUPDATE BUS:Queries option buses and updates list ofconnected devices.SETUP KEYPAD: 0PIN REQUIRED:LOCAL:REMOTE:REMOTE PGM0- No1- Yes0- disablePROG INPUTSPOINT NUMBER (1-4/5-8/9-255)FUNCTION Point Function 1 = 1Point Function 2 = 2Point Function 3 = 3Bosch Security System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> Appendices | en 111PROG TIMESYSTEM: Last date in EE 0000AUTO TESTTEST TIME: 0200TEST FREQ:DAYLIGHT SAV:3 hr to 24 hr2- enableSECURITYPINSPROGRAMMER: 9876USERS: User 1 = 1234User 2 = 0000AUTHORITYUSER 1: 2OTHERS: 0PROG SYSTEMTIMERSSMOKE RESET:AC FAIL DELAY:AUTO SILENCE:DISPLAY RATE:AC LINE SYNCH6 sec6 hr0 min4x.25 = 1 sec2 (60 Hz)OPTION BUSUPDATE BUS:Queries option buses and updates list ofconnected devices.SETUP KEYPAD: 0PIN REQUIRED:LOCAL:REMOTE:REMOTE PGM0- No1- Yes0- disablePROG INPUTSPOINT NUMBER (1-4/5-8/9-255)FUNCTION Point Function 1 = 1Point Function 2 = 2Point Function 3 = 3<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!