<strong>Report</strong> of returned spindlesReturn no.Product no.Product name99903671940504AB-0026ManufacturerMFR-Mat-Nr. :Product Type:MFR-Serial-Nr. :Motor coolingNot OKoflow rate to low<strong>Spindle</strong> shaftNot OKocontrol egde tolerancelimit reachedRemark:Release unit: There was no leakage during a loop test run (permanent "clamp/unclamp")of 30 minutes with 130 bars.Comment / Failure / CauseThe fail of the spindle is due to interwinding fault in the stator. The flow rateof the motor cooling was not sufficient because of the clogged coolingsleeve.Revision 99903671 / 5Page 7 of 9