11.07.2015 Views

TT mini S - Blažek Power Transmission

TT mini S - Blažek Power Transmission

TT mini S - Blažek Power Transmission

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Products & Applications<strong>TT</strong> <strong>mini</strong> Sfrequency measuring deviceOperating instructionsDrive solutions with Optibelt


optibelt <strong>TT</strong> <strong>mini</strong> SThe optibelt <strong>TT</strong> <strong>mini</strong> S frequency measuringdevice is used to establish the tension of transmission beltsby means of frequency measuring.Operating instructions1234Switch on the <strong>TT</strong> <strong>mini</strong> S by pushing the ac -button. On thedisplay appears an A for „active“, immediately afterwards thedevice is ready for measuring (the display now shows a m).Vibrate the tensioned belt either by finger or by usingan appropriate tool. Hold the measuring head over thebelt to be measured.Given a constant frequency the measurement starts witha measuring result. The start is being displayed by aLCD. After the measuring evaluation, the result is displayedin Hertz, the m fades. Next to the A a number of1 to 4 is displayed. This number represents the numberof successful measuring cycles. If 2 to 4 measurementsare necessary, a statistical value is being calculated.If an E is displayed behind the number, one of themeasuring results was outside the range of tolerance.In case the display shows 1 or E it is recommended thatthe measurement is being repeated by pressing againonthe -button.acThe measuring frequency [Hz] is to be compared withthe nominal value [Hz]. Decrease or increase the belttension, depending on the measuring result, up to setthe value. The conversion of the measuring frequencyf [Hz] into static belt tension T [N] is done with thefollowing formulae:onTechnical DataMeasuring range:10-600 HzMeasuring accuracy:10-400 Hz ± 1%> 400 Hz ± 2 %Sensor:Acoustical with electronicbackground fade-outT = 4 · k · l 2 · f 2T = static belt tension [N] l = span length [m]k = weight per metre [kg/m] f = frequency [Hz]The tension value and weight per metre can be gatheredfrom the Optibelt CAP drive design calculation and theOptibelt documentation respectively.<strong>Power</strong> supply:2 batteries Micro (AAA-cells)Verification:CE acceptanceFactory calibration5The <strong>TT</strong> <strong>mini</strong> S can be switched off by pressing theoff-button. Furthermore, an automatic cut off takes placeafter a few minutes.Safety advice!Before the start of measurement, the drive motor must be switched off, thus ensuringthat neither the drive nor the driven shaft can start rotating. All the corresponding safetymeasures must be strictly complied with!

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!