11.07.2015 Views

Inline – The IP20 I/O system for the control cabinet - Phoenix Contact

Inline – The IP20 I/O system for the control cabinet - Phoenix Contact

Inline – The IP20 I/O system for the control cabinet - Phoenix Contact

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Inline</strong> –<strong>The</strong> <strong>IP20</strong> I/O <strong>system</strong><strong>for</strong> <strong>the</strong> <strong>control</strong> <strong>cabinet</strong>


<strong>The</strong> complete I/O portfolio<strong>for</strong> <strong>the</strong> <strong>control</strong> <strong>cabinet</strong>I/O terminals and function terminals <strong>for</strong>all common networks and bus <strong>system</strong>s:Combine <strong>the</strong> required automationfunctions easily and individually using<strong>the</strong> <strong>Inline</strong> automation kit from <strong>Phoenix</strong><strong>Contact</strong>.Irrespective of whe<strong>the</strong>r it is central in<strong>the</strong> <strong>control</strong> <strong>cabinet</strong> or distributed in<strong>the</strong> terminal box, modular alignmentor compact I/O modules – modulesadapted to your special requirementsensure maximum flexibility in <strong>the</strong>application-specific configuration.Take a look at our wide range!2 PHOENIX CONTACT


Table of contents<strong>Inline</strong> – <strong>The</strong> <strong>system</strong>Pages 4 – 9Industry solutionsPages 10 – 11Bus-open and scalablePages 12 – 13Completely safePages 14 – 17Easy to extendPages 18 – 19SoftwarePages 20 – 21Product overviewPages 22 – 38AccessoriesPage 39PHOENIX CONTACT 3


Automation terminals<strong>for</strong> all functionsflexibleMaximum modularity<strong>The</strong> <strong>Inline</strong> Modular automation kit stands<strong>for</strong> "Plugging instead of wiring" and connectssensors and actuators to <strong>the</strong> relevant networkor bus <strong>system</strong> with minimum wiring andmaximum functions. Thanks to its optimumadaptability to every automation task, <strong>the</strong>highly modular <strong>Inline</strong> I/O <strong>system</strong> has a varietyof applications – whe<strong>the</strong>r it is its ideal numberof channels or <strong>the</strong> variety of functions withhigh reliability.space-savingHigh packing densityof <strong>the</strong> I/O channelsversatileWide range offunction terminals4 PHOENIX CONTACT


Due to its compact and extremely flatdesign, <strong>Inline</strong> Block IO is <strong>the</strong> optimumaddition to <strong>Inline</strong> Modular IO.Save space on <strong>the</strong> DIN rail with <strong>the</strong>sepre-fabricated block modules. <strong>The</strong>ycombine a fixed number of I/Os witha network or bus connection. You canenjoy significant advantages in terms ofhandling and costs, particularly in <strong>the</strong>case of machines and <strong>system</strong>s with lowI/O occurrence.simpleUser-friendly integrationand operationreliableInternational approvalsopenSupports allcommon networksand bus <strong>system</strong>stime-savingToolless assembly andaccurate diagnosticssafeEasy integration ofsafety modulesseamlessStandard I/Os as block or modular –all in <strong>the</strong> uni<strong>for</strong>m <strong>Inline</strong> conceptPHOENIX CONTACT 5


<strong>Inline</strong> Modular IO – flexible and versatileAn <strong>Inline</strong> station is configured with highgranularity in <strong>the</strong> case of digital and analoginputs or outputs with 1, 2, 4, 8, 16 up to32 channels. <strong>The</strong> required functions areeasily combined on <strong>the</strong> DIN rail behind <strong>the</strong>bus coupler as per <strong>the</strong> "Pl ugging instead ofwiring" principle <strong>for</strong> <strong>the</strong> desired network orbus <strong>system</strong>.Sensors and actuators are connected usingspecial COMBICON I/O connectors withspring-cage technology. A one, two, threeor four-wire conductor connection methodis possible.Clearly numbered terminalpointsColored LED fields with statusand diagnostic LEDsPower-in or segment terminalColored labeling of <strong>the</strong>terminal pointsBus couplerNetwork or busconnection6 PHOENIX CONTACT


I/O modules<strong>Inline</strong> Modular enables a flexible andapplication-specific configuration of digitaland analog I/O channels including <strong>the</strong> mostcommon standard functions:• Counting events• Generating impulses• Switching power• Guaranteeing safety• Recording and approaching position• Regulating speed• Recording and regulating temperature• Exchanging data• Controlling pneumatic components• Evaluating strain gauges• Connecting bus master (CAN, PB)Shield connection Supply and segmentationVarious segment current circuits can beset up within an <strong>Inline</strong> station using <strong>the</strong><strong>Inline</strong> segment terminals.Creating an AC areaAC areas can be set up within an <strong>Inline</strong>station using special AC power and endterminals.Integration of power-level terminalsA 400 V power bus is fed and bridgedfur<strong>the</strong>r at <strong>the</strong> first <strong>Inline</strong> power-levelterminal.Note: <strong>The</strong> configuration and <strong>the</strong> wiring concept are illustrated here as an example <strong>for</strong> connection to INTERBUS. Detailed in<strong>for</strong>mation on <strong>the</strong> <strong>Inline</strong> <strong>system</strong> and connection too<strong>the</strong>r fieldbuses and networks can be found in <strong>the</strong> <strong>Inline</strong> data sheets or <strong>system</strong> manual on <strong>the</strong> Internet at: www.phoenixcontact.net/catalog.


<strong>Inline</strong> Block IO is ideal <strong>for</strong> use in terminalboxes thanks to its compact and low-profiledesign of just 55 mm.Wiring is done using <strong>the</strong> proven <strong>Inline</strong>connectors. Moreover, sensors and actuatorscan be connected using a 2, 3 or 4-wireconductor connection method and fur<strong>the</strong>rrouting is thus not necessary.Clear numbering and colored labels help <strong>the</strong>user when handling <strong>the</strong> modules.Voltages <strong>for</strong> logic as well as sensor andSeparate power supply unitsI/O connectors withspring-cage terminal blocksactuator <strong>system</strong>s can be connected usingseparate contacts.Network or busconnectionPluggable I/O connection<strong>The</strong> COMBICON connection methodestablishes <strong>the</strong> connection betweenmodule and I/O devices reliably.Clear marking and labelingPlain text labeling fields and standardZack marker strips provide top convenience<strong>for</strong> professional labeling.EncodingEncoding of <strong>the</strong> connection points ofterminals and connectors with keyingprofile IL CP provides additional safety.


<strong>Inline</strong> Block IO – simple and space-savingColored LED fields withstatus and diagnostic LEDsClear numbering of terminalpointsColored labeling of <strong>the</strong>terminal points<strong>Inline</strong> Block IO is available in two differenthousing widths:95 mm and 156 mm.Devices with only digital inputs or outputsor analog I/O modules are also availablein addition to those with different inputand output combinations. <strong>The</strong> range isrounded off by devices with motion <strong>control</strong>and wireless connection functionality.<strong>The</strong> function of <strong>the</strong> channels can befreely selected <strong>for</strong> some modules only byconnecting <strong>the</strong> sensor or <strong>the</strong> actuator.Technical data – <strong>Inline</strong> Modular IO and <strong>Inline</strong> Block IOAmbient conditionsOperating temperature rangeStorage temperatureRelative humidity (operation)Relative humidity (storage)VibrationShockDegree of protectionElectromagnetic compatibilityNoise emissionNoise immunity-25°C ... +55°C (<strong>Inline</strong> Modular IO)-25°C ... +60°C (<strong>Inline</strong> Block IO)-25°C ... +85°C5% to 95% (no condensation)5% to 95% (no condensation)5 g, 2 hours in each space direction according toIEC 60068-2-625 g, over 11 ms according to IEC 60068-2-27<strong>IP20</strong> (according to IEC 60529)EN 61000-6-4EN 61000-6-2Supply voltageNominal valueRipplePermissible range24 V DC±5% according to EN 61131-219.2 V ... 30.0 VPHOENIX CONTACT 9


Scalable <strong>control</strong>lersControl <strong>system</strong>s <strong>for</strong> simple service requirementsClass 100 compact <strong>control</strong>lers support high-per<strong>for</strong>mance<strong>control</strong> functions and communicate via E<strong>the</strong>rnet, wirelessnetwork or fixed-line network.You can easily align all <strong>Inline</strong> I/O modules required underdegree of protection <strong>IP20</strong> with <strong>the</strong> PLC and <strong>the</strong>rebyintegrate all industry-relevant sensors and actuators into<strong>the</strong> <strong>system</strong>.Control <strong>system</strong>s <strong>for</strong> medium service requirements<strong>The</strong> <strong>Inline</strong> <strong>control</strong>lers of per<strong>for</strong>mance class 300 have one ortwo E<strong>the</strong>rnet ports, thus facilitating flexible connection to<strong>the</strong> higher-level <strong>control</strong> room, a local operating station orI/O modules.PHOENIX CONTACT 13


Safe and flexible –SafetyBridge I/OsA new addition to <strong>the</strong> <strong>Inline</strong> range comesin <strong>the</strong> <strong>for</strong>m of SafetyBridge technology.Integrated in yellow, safe I/Os, thistechnology provides functional safety inyour automation networks. You can freelydistribute <strong>the</strong> safe I/O modules in yourmachine and <strong>system</strong>. Your standard <strong>control</strong><strong>system</strong> and <strong>the</strong> safe I/Os provide a networkindependentsafety solution.<strong>The</strong> safety function is easily configured viadrag & drop using <strong>the</strong> free SAFECONFsoftware.Input module<strong>The</strong> input module detects <strong>the</strong>digital safety signals decentrally in<strong>the</strong> network. It has up to eight safeinputs onboard.Output moduleWith up to eight safe outputs, <strong>the</strong>digital safety signals are outputdecentrally from <strong>the</strong> output module.14 PHOENIX CONTACT


How does SafetyBridge technology work?SafetyBridge I/Os exchange safe signals via anautomation network. This technology uses <strong>the</strong>standard <strong>control</strong> <strong>system</strong> and <strong>the</strong> existing networkas a transport medium. Safety-related tasks areper<strong>for</strong>med exclusively by <strong>the</strong> logic module, because itgenerates and links <strong>the</strong> entire SafetyBridge protocol.<strong>The</strong> SafetyBridge protocol can be transmitted via anynetwork.Copyingprocedure <strong>for</strong><strong>the</strong> standard<strong>control</strong> <strong>system</strong>I/O moduleLogic moduleLogic module<strong>The</strong> logic module links all safety functions in<strong>the</strong> network. Equipped with a main memoryand a Flash memory, it can be combined withup to five input or output modules.SAFECONF<strong>The</strong> safety function can be easily configuredusing SAFECONF.<strong>The</strong> configuration software provides afunction check simulation and is available as afree download.PHOENIX CONTACT 15


Use in explosive areas –intrinsically safe I/Os<strong>The</strong> intrinsically safe blue I/Os connect inputand output signals to your network or bus<strong>system</strong>.<strong>The</strong> blue I/O modules can be used in bothpotentially explosive areas and non-explosiveareas. Simply mount <strong>the</strong> modules on <strong>the</strong><strong>Inline</strong> station. Parameterize <strong>the</strong> terminalswith FDT technology and use channelspecificdiagnostics <strong>for</strong> trouble-shooting.Ex-i temperature input<strong>The</strong> 4-channel temperature input modulesupports standard <strong>the</strong>rmocouple sensors andcommercially available resistive temperaturemeasuringdevices. An onboard shieldconnection enables easy wiring and providesprotection against electromagnetic interference.16 PHOENIX CONTACT


Analog Ex-i I/O moduleThanks to two current ranges (0/4 to 20 mA)<strong>for</strong> input and output, as well as an inputvoltage range of 0 to 10 V, this 4-channelmodule can be used universally.Operating and installing I/Osin Ex zonesNon-explosiveareaDigital Ex-i I/O module<strong>The</strong> 4-channel digital I/O modulesupports inputs <strong>for</strong> Namurinitiators and mechanicalcontacts, outputs <strong>for</strong> intrinsicallysafe solenoid valves, acousticalarm messages and LEDs/signallamps.ZONE 20.0 – 0.1% per year ormax. 10 hoursEx-i power supply unit<strong>The</strong> power supply unit displays <strong>the</strong> current statusacross several <strong>control</strong> displays. In <strong>the</strong> case of <strong>the</strong>supply terminal, <strong>the</strong> voltage present, high load rangeand overload states must be differentiated between.<strong>The</strong> terminal is electronically secured against overload.<strong>The</strong> intrinsically safe power supply unit operates ata very high level of energy efficiency.ZONE 1 and 210.1 – 10% per year ormax. 10 – 1000 hoursZONE 0 and 20> 10% per year or> 1000 hoursPHOENIX CONTACT 17


Open <strong>for</strong> easy field expansion from<strong>the</strong> <strong>control</strong> <strong>cabinet</strong> into <strong>the</strong> fieldWith <strong>the</strong> <strong>Inline</strong> local bus extension, youcan integrate IP65/67 components into <strong>the</strong><strong>Inline</strong> <strong>IP20</strong> <strong>system</strong>. In this way, you remainflexible when detecting signals – whe<strong>the</strong>rdirectly in <strong>the</strong> <strong>control</strong> <strong>cabinet</strong> or close to<strong>the</strong> process in <strong>the</strong> field.<strong>Inline</strong> Modular IOWith this terminal block, you can alsodistribute <strong>the</strong> <strong>Inline</strong> station across severalDIN rails within <strong>the</strong> <strong>control</strong> <strong>cabinet</strong>.Local bus extensionE<strong>the</strong>rnetmax.100 mEntire local bus spreadmax. 100 m18 PHOENIX CONTACT


Entire local bus spread max. 20 mSimplestpoint-to-pointcommunicationFieldline Modular M8max. of16 devices2 m ring = 1 mlocal busspreadSignal transmission with <strong>Inline</strong> fieldmultiplexers<strong>The</strong> <strong>Inline</strong> Modular field multiplexertransmits all data serially, frompoint-to-point – be it via a single 2-wirecopper cable, an FO cable, a modem orwireless transmission.A number of digital and analog <strong>Inline</strong>Modular I/O terminals can be freelycombined – and that too without usingany software.PropertiesData transmission via:• 2-wire copper cable up to 12 km• Dedicated telephone line up to 20 km(with converter)• Fiber optics up to 45 km (with converter)max. 20 mFieldline Modular M12max. of16 devicesLocal bus extensionWith <strong>the</strong> <strong>Inline</strong> local bus extension terminal, <strong>the</strong> numberof bus couplers is reduced, <strong>the</strong>reby reducing <strong>the</strong> devicesin <strong>the</strong> network when installing across several lines in <strong>the</strong><strong>control</strong> <strong>cabinet</strong>. Even <strong>the</strong> Fieldline IP65/67 components canbe connected directly from <strong>the</strong> <strong>control</strong> <strong>cabinet</strong> into <strong>the</strong>field without using a bus coupler. <strong>The</strong>re is also <strong>the</strong> option ofconnecting up to three I/O devices to <strong>the</strong> base stations viaa robust Bluetooth connection.WirelessI/O modulesPHOENIX CONTACT 19


Only a few steps away froma functional applicationThanks to our universal software tools,implementation of an automation solutionhas now become more convenient <strong>for</strong> you.Seamless from one tool to <strong>the</strong> next, anddata once generated, from <strong>the</strong> definition ofan <strong>Inline</strong> station to <strong>the</strong> complete applicationprogram and circuit diagram, can be easilyused in o<strong>the</strong>r tools.2. Configuration in CLIP PROJECTCLIP PROJECT allows you to configureautomation and interface components, as wellas surge protection and modular terminalblocks quickly and easily. Labels can beattached easily.Integrated interfaces allow export of data toelectrical planning <strong>system</strong>s such as EPLAN.1. Configuration in Project+Project+ automates configuration andrequests <strong>for</strong> offer <strong>for</strong> an <strong>Inline</strong> stationby simply entering <strong>the</strong> desiredfunctions and automatic verificationof all <strong>Inline</strong> <strong>system</strong> limits. <strong>The</strong>complete configuration can beused <strong>for</strong> fur<strong>the</strong>r processing underCLIP PROJECT.20 PHOENIX CONTACT


Express3. Programming and parameterizationusing PC WORX and SAFECONFPC WORX is <strong>the</strong> automation software <strong>for</strong>all PC-based and embedded <strong>control</strong> <strong>system</strong>sfrom <strong>Phoenix</strong> <strong>Contact</strong>.With Config+ <strong>Inline</strong> stations can also beconfigured <strong>for</strong> external <strong>control</strong> <strong>system</strong>s.<strong>The</strong> SAFECONF software is used freeof charge <strong>for</strong> safety applications that areper<strong>for</strong>med decentrally using SafetyBridgetechnology.Integration in o<strong>the</strong>r <strong>control</strong><strong>system</strong>s<strong>The</strong> extensive network-specific devicedescription files that can be read in<strong>the</strong> respective automation <strong>system</strong>through drag & drop guarantee correctintegration and easy parameterizationof <strong>Inline</strong>, irrespective of <strong>the</strong> respective<strong>control</strong> <strong>system</strong>.4. Visualization with Visu+Data projected in PC WORXcan be processed fur<strong>the</strong>r <strong>for</strong>visualization purposes, <strong>for</strong> instance,in <strong>the</strong> Visu+ visualization softwarefrom <strong>Phoenix</strong> <strong>Contact</strong>. Visu+ isconnected to <strong>the</strong> <strong>control</strong> <strong>system</strong>through OPC and can thus also beused irrespective of its manufacturer.5. Diagnostics using Diag+During operation, <strong>the</strong> Diag+ softwaresupports you with accurate on <strong>the</strong>spot diagnostics. This software hasbeen specially adapted to INTERBUSand PROFINET IO and integrated intoPC WORX. However, it can also be usedas independent software.PHOENIX CONTACT 21


<strong>Inline</strong> product overviewE<strong>the</strong>rnetIL PN BK DI8 DO4 2TX-PACIL PN BK DI8 DO4 2SCRJ-PACILB PN 24 DI16 DIO16-2TXOrder No. 2703994 Order No. 2878379 Order No. 2878146• PROFINET I/O devicefunctionality (stack 2.2)• 8 inputs, 24 V DC• 4 outputs, 500 mA• 0.8 A at U L• RJ45 connection• 80 mm design width• PROFINET I/O devicefunctionality (stack 3.1)• 8 inputs, 24 V DC• 4 outputs, 500 mA• 0.8 A at U L• SCRJ connection• 80 mm design width• 16 inputs, 24 V DC• 16 I/Os, 24 V DC, 500 mA (can befreely selected)• 2 and 3-wire connection• Integrated 3-port switch• Bus connection viaRJ45 connector• 156 mm design widthModbus/TCP(UDP)Modbus/TCPIL EIP BK DI8 DO4 2TX-PACIL ETH BK DI8 DO4 2TX-PACILB ETH 24 DI16 DIO16-2TXOrder No. 2897758 Order No. 2703981 Order No. 2832962• E<strong>the</strong>rnet/IP-compatible• HTTP, BootP• 8 inputs, 24 V DC• 4 outputs, 500 mA• 0.8 A at U L• RJ45 connection• 80 mm design width• Modbus/TCP (UDP)-compatible• HTTP, TFTP, BootP, SNMP• 8 inputs, 24 V DC• 4 outputs, 500 mA• 0.8 A at U L• RJ45 connection• 80 mm design width• 16 inputs, 24 V DC• 16 I/Os, 24 V DC, 500 mA (can befreely selected)• 2 and 3-wire connection• Integrated 3-port switch• Bus connection viaRJ45 connector• 156 mm design widthIL S3 BK DI8 DO4 2TX-PAC22 PHOENIX CONTACTILB S3 24 DI16 DIO 16-2TXILB IB AI4 AO2ILB S3 24 DI8 DO4 AO2INC-IN2Order No. 2692380 Order No. 2897570 Order No. 2878777 Order No. 2700174• SERCOS III I/O profile (V1.1.2)• 8 inputs, 24 V DC• 4 outputs, 500 mA• 0.8 A at U L• RJ45 connection• 80 mm design width• 16 inputs, 24 V DC• 16 I/Os, 24 V DC, 500 mA (can befreely selected)• 2 and 3-wire connection• Bus connection viaRJ45 connector• 156 mm design width• 4 inputs, 0 - 5 V, ±5 V, 0 - 10 V, ±10 V,0 - 20 mA, ±20 mA, 4 - 20 mA,Pt100, Pt500, Pt1000, etc.• 2 outputs, 0 - 5 V, ±5 V, 0 - 10 V,±10 V, 0 - 20 mA, ±20 mA, 4 - 20 mA• 16 bits• 156 mm design width• Positioning <strong>control</strong>ler <strong>for</strong> 2 axes• 2 analog outputs, ±10 V• 2 inputs <strong>for</strong> incremental encoder• 8 digital inputs, 24 V DC• 4 digital outputs, 24 V DC, 500 mA• 2 and 3-wire connection• Bus connection viaRJ45 connector• 156 mm design width


FieldbusesIBS IL 24 BK-T/U-PAC IBS IL 24 BK-LK/45-PAC IBS IL 24 BK RB-LK-PACOrder No. 2861580 Order No. 2862165 Order No. 2861506• INTERBUS• Incl. branch bus terminal support• 2 A at U L• Direct connection withconnector• 48.8 mm design width• INTERBUS• 2 A at U L• Fiber optic connection, 45°outlet• 85 mm design width• INTERBUS• With INTERBUS remote busbranch• 2 A at U L• Fiber optic connection• 85 mm design widthILB IB 24 DI16 ILB IB 24 DI32 ILB IB 24 DO16 ILB IB 24 DO32Order No. 2862330 Order No. 2862343 Order No. 2862356 Order No. 2862369• 16 inputs, 24 V DC• 2 and 3-wire connection• Bus connection via <strong>Inline</strong>connector• 95 mm design width• 32 inputs, 24 V DC• 2 and 3-wire connection• Bus connection via <strong>Inline</strong>connector• 156 mm design width• 16 outputs, 24 V DC, 500 mA• 2 and 3-wire connection• Bus connection via<strong>Inline</strong> connector• 95 mm design width• 32 outputs, 24 V DC, 500 mA• 2 and 3-wire connection• Bus connection via<strong>Inline</strong> connector• 156 mm design widthILB IB 24 DI 8 DO 8 ILB IB 24 DI16 DO16 ILB IB AI4 AO2Order No. 2862372 Order No. 2862385 Order No. 2878777• 8 inputs, 24 V DC• 8 outputs, 24 V DC, 500 mA• 2 and 3-wire connection• Bus connection via <strong>Inline</strong>connector• 95 mm design width• 16 inputs, 24 V DC• 16 outputs, 24 V DC, 500 mA• 2 and 3-wire connection• Bus connection via <strong>Inline</strong>connector• 156 mm design width• 4 inputs, 0 - 5 V, ±5 V, 0 - 10 V,±10 V, 0 - 20 mA, ±20 mA,4 - 20 mA, Pt100, Pt500, Pt1000,etc.• 2 outputs, 0 - 5 V, ±5 V, 0 - 10 V,±10 V, 0 - 20 mA, ±20 mA,4 - 20 mA• 16 bits• 156 mm design widthPHOENIX CONTACT 23


FieldbusesIL PB BK DI8 DO4/EF-PAC IL PB BK DP/V1-PAC ILB PB 24 DI32 ILB PB 24 DO32Order No. 2692322 Order No. 2862246 Order No. 2862398 Order No. 2862408• PROFIBUS DP and DP/V1• PROFIsafe-compatible• IO-Link calls• 8 inputs, 24 V DC• 4 outputs, 500 mA• 0.8 A at U L• D-SUB connection• 80 mm design width• PROFIBUS DP and DP/V1• 2 A at U L• D-SUB connection• 85 mm design width• 32 inputs, 24 V DC• 2 and 3-wire connection• Bus connection viaD-SUB connector• 156 mm design width• 32 outputs, 24 V DC, 500 mA• 2 and 3-wire connection• Bus connection viaD-SUB connector• 156 mm design widthILB PB 24 DI16 DO16 ILB PB 24 DI8 DIO8 ILB PB AI4 AO2Order No. 2862411 Order No. 2863562 Order No. 2878874• 16 inputs, 24 V DC• 16 outputs, 24 V DC, 500 mA• 2 and 3-wire connection• Bus connection viaD-SUB connector• 156 mm design width• 8 inputs, 24 V DC• 8 I/Os, 24 V DC, 500 mA (can befreely selected)• Bus connection viaD-SUB connector• 95 mm design width• 4 inputs, 0 - 5 V, ±5 V, 0 - 10 V,±10 V, 0 - 20 mA, ±20 mA,4 - 20 mA, Pt100, Pt500, Pt1000,etc.• 2 outputs, 0 - 5 V, ±5 V, 0 - 10 V,±10 V, 0 - 20 mA, ±20 mA,4 - 20 mA• 16 bits• 156 mm design widthModbus/RTUIL DN BK DI8 DO4-PAC ILB DN 24 DI16 DO16 IL MOD BK DI8 DO4-PACOrder No. 2897211 Order No. 2862602 Order No. 2878696• DeviceNet TM• 8 inputs, 24 V DC• 4 outputs, 500 mA• 0.8 A at U L• TWIN-COMBICON connection• Incl. CLIPFIX 35 end clamp• 80 mm design width• 16 inputs, 24 V DC• 16 outputs, 24 V DC, 500 mA• 2 and 3-wire connection• Bus connection via TWIN-COMBICON connector• 156 mm design width• Modbus/RTU (ASCII)• 8 inputs, 24 V DC• 4 outputs, 500 mA• 0.8 A at U L• D-SUB connection• 80 mm design width24 PHOENIX CONTACT


FieldbusesIL CAN BK-TC-PAC ILB CO 24 DI16 DO16 IL MII BK DI8 DO4-PAC IB IL 24 MUX MA-PACOrder No. 2718701 Order No. 2862592 Order No. 2884619 Order No. 2861205• CANopen• 2 A at U L• TWIN-COMBICON connection• Incl. CLIPFIX 35 end clamp• 85 mm design width• 16 inputs, 24 V DC• 16 outputs, 24 V DC, 500 mA• 2 and 3-wire connection• Bus connection viaD-SUB connector• 156 mm design width• Mechatrolink slave functionality• 8 inputs, 24 V DC• 4 outputs, 500 mA• 0.8 A at U L• USB connection• 80 mm design width• Point-to-point transmission ofmax. 512 I/O data via 2-wire cablesup to max. 12 km• 48.8 mm design width<strong>Inline</strong> Controllers – Class 100 compact <strong>control</strong>lersILC 130 ETH ILC 150 ETH ILC 170 ETH 2TX ILC 190 ETH 2TXOrder No. 2988803 Order No. 2985330 Order No. 2916532 Order No. 2700527• Typical processing speed of 1.7 ms<strong>for</strong> 1 K instructions• 192 KB program memory• 192 KB data memory• 8 KB retentive data memory• 1 E<strong>the</strong>rnet interface• 8 direct inputs• 4 direct outputs• 80 mm design width• Typical processing speed of 1.5 ms<strong>for</strong> 1 K instructions• 256 KB program memory• 256 KB data memory• 8 KB retentive data memory• 1 E<strong>the</strong>rnet interface• 8 direct inputs• 4 direct outputs• 80 mm design width• Typical processing speed of 1.5 ms<strong>for</strong> 1 K instructions• 512 KB program memory• 512 KB data memory• 48 KB retentive data memory• 2 E<strong>the</strong>rnet interfaces• 8 direct inputs• 4 direct outputs• 80 mm design width• Typical processing speed of 1.3 ms<strong>for</strong> 1 K instructions• 1 MB program memory• 1 MB data memory• 48 KB retentive data memory• 2 E<strong>the</strong>rnet interfaces• 8 direct inputs• 4 direct outputs• 80 mm design widthILC 150 GSM/GPRSOrder No. 2916545• Typical processing speed of 1.5 ms<strong>for</strong> 1 K instructions• 512 KB program memory• 512 KB data memory• 48 KB retentive data memory• Integrated GSM/GPRS modem• 1 E<strong>the</strong>rnet interface• 16 direct inputs• 4 direct outputs• 80 mm design widthPHOENIX CONTACT 25


<strong>Inline</strong> Controllers – Class 300 compact <strong>control</strong>lersILC 330 PN ILC 350 PN ILC 370 PN 2TX-IB ILC 390 PN 2TX-IBOrder No. 2988191 Order No. 2876928 Order No. 2876915 Order No. 2985314• Typical processing speed of 0.7 ms<strong>for</strong> 1 K instructions• 750 KB program memory• 1.5 MB data memory• 64 KB retentive data memory• 1 PROFINET interface (10/100)• 12 direct inputs• 4 direct outputs• 182 mm design width• Typical processing speed of 0.5 ms<strong>for</strong> 1 K instructions• 1 MB program memory• 2 MB data memory• 64 KB retentive data memory• 1 PROFINET interface (10/100)• 12 direct inputs• 4 direct outputs• 182 mm design width• Typical processing speed of 0.5 ms<strong>for</strong> 1 K instructions• 1 MB program memory• 2 MB data memory• 64 KB retentive data memory• 2 PROFINET interfaces (10/100)• 1 INTERBUS interface• 12 direct inputs• 4 direct outputs• 182 mm design width• Typical processing speed of 0.2 ms<strong>for</strong> 1 K instructions• 2 MB program memory• 4 MB data memory• 96 KB retentive data memory• 2 PROFINET interfaces (10/100)• 1 INTERBUS interface• 12 direct inputs• 4 direct outputs• 182 mm design widthILC 370 PN 2TX-IB/MOrder No. 2985576• Maritime approval26 PHOENIX CONTACT


Power and segment terminalsPower terminals (<strong>for</strong> supplying <strong>the</strong> I/O voltage)IB IL 24 PWR IN-PACIB IL 24 PWR IN/2-F-PACIB IL 24 PWR IN/2-F-D-PACIB IL 24 PWR IN/2F-DF-PACIB IL 120 PWR IN-PACOrder No. 2861331 Order No. 2862136 Order No. 2862152 Order No. 2863779 Order No. 2861454• 24 V DC (U M , U S )• 12.2 mm design width• 24 V DC (U M , U S )• With fuse• 12.2 mm design width• 24 V DC (U M , U S )• With fuse anddiagnostics (UM, fuse)• 12.2 mm design width• 24 V DC (U M , U S )• With fuse anddiagnostics (fuse)• 12.2 mm design width• 120 V AC• Incl. distance terminal• 36.6 mm design width(24.4 mm + 12.2 mm)Power terminals Potential distributor terminals Boost terminalIB IL 230 PWR IN-PACIB IL 230 PWR IN/F-D-PACIB IL PD 24V-PACIB IL PD GND-PACIB IL 24 PWR IN/R-PACOrder No. 2861535 Order No. 2878971 Order No. 2862987 Order No. 2862990 Order No. 2861674• 230 V AC• Incl. distance terminal• 36.6 mm design width(24.4 mm + 12.2 mm)• 230 V AC• With fuse anddiagnostics• Incl. distance terminal• 36.6 mm design width(24.4 mm + 12.2 mm)• 24 V DC (from U S )• 8 contacts• 12.2 mm design width• GND• 8 contacts• 12.2 mm design widthFor boosting <strong>the</strong>communications powerand I/O voltage•U L , U ANA , U M, U S• 48.8 mm design widthBoost terminalSegment terminals (<strong>for</strong> segmenting <strong>the</strong> I/O voltage)IB IL 24 PWR IN/R/L-0.8A-PACIB IL 24 SEG-PACIB IL 24 SEG/F-PACIB IL 24 SEG/F-D-PACIB IL 24 SEG-ELF-PACOrder No. 2693020 Order No. 2861344 Order No. 2861373 Order No. 2861904 Order No. 2861409For boosting <strong>the</strong>communications powerup to 0.8 A•U L• 12.2 mm design width• 24 V DC• 12.2 mm design width• 24 V DC• With fuse• 12.2 mm design width• 24 V DC• With fuse anddiagnostics• 12.2 mm design width• 24 V DC, 2.5 A• With electronic fuse anddiagnostics• 12.2 mm design widthPHOENIX CONTACT 27


Digital input terminals1 channel 1 channel 2 channels 2 channels 4 channelsIB IL 120 DI 1-PAC IB IL 230 DI 1-PAC IB IL 24 DI 2-PACIB IL 24 DI 2-NPN-IB IL 24 DI 4-PACPACOrder No. 2861917 Order No. 2861548 Order No. 2861221 Order No. 2861483 Order No. 2861234• 1 input• 120 V AC• 3-wire connection• 12.2 mm design width• 1 input• 230 V AC• 3-wire connection• 12.2 mm design width• 2 inputs• 24 V DC• 4-wire connection• 12.2 mm design width• 2 inputs• 24 V DC• 4-wire connection• NPN-wired• 12.2 mm design width• 4 inputs• 24 V DC• 3-wire connection• 12.2 mm design width8 channels 8 channels 8 channels 16 channels 16 channelsIB IL 24 DI8/HD-PAC IB IL 24 DI 8-PAC IB IL 24 DI 8/T2-PAC IB IL 24 DI 16-PACIB IL 24 DI 16-NPN-PACOrder No. 2700173 Order No. 2861247 Order No. 2862204 Order No. 2861250 Order No. 2863520• 8 inputs• 24 V DC• Single-wire connection• 12.2 mm design width• 8 inputs• 24 V DC• 4-wire connection• 48.8 mm design width• 8 inputs• 24 V DC• 4-wire connection• Input according toEN 61131-2/type 2• 48.8 mm design width• 16 inputs• 24 V DC• 3-wire connection• 48.8 mm design width• 16 inputs• 24 V DC• 3-wire connection• NPN-wired• 48.8 mm design width32 channels 32 channelsIB IL 24 DI 32/HD-PACIB IL 24 DI 32/HD-NPN-PACOrder No. 2862835 Order No. 2878243• 32 inputs• 24 V DC• Single-wire connection• 48.8 mm design width• 32 inputs• 24 V DC• Single-wire connection• NPN-wired• 48.8 mm design width28 PHOENIX CONTACT


Digital output terminals1 channel 2 channels 2 channels 2 channels 2 channelsIB IL DO 1 AC-PACIB IL 24 DO 2-PACIB IL 24 DO 2-2A-PACIB IL 24 DO 2-NPN-PACIB IL 24 EDO 2-PACOrder No. 2861920 Order No. 2861470 Order No. 2861263 Order No. 2861496 Order No. 2861616• 1 output• 12 - 253 V AC, 500 mA• 3-wire connection• 12.2 mm design width• 2 outputs• 24 V DC, 500 mA• 4-wire connection• 12.2 mm design width• 2 outputs• 24 V DC, 2 A• 4-wire connection• 12.2 mm design width• 2 outputs• 24 V DC, 500 mA• 4-wire connection• NPN-wired• 12.2 mm design width• 2 outputs• 24 V DC, 500 mA• Parameterizableoutput behavior• 12.2 mm design width4 channels 4 channels 8 channels 8 channels 8 channelsIB IL 24 DO 4-PACIB IL DO 4 AC-1A-PACIB IL 24 DO8/HD-PACIB IL 24 DO 8-PACIB IL 24 DO 8-2A-PACOrder No. 2861276 Order No. 2861658 Order No. 2700172 Order No. 2861289 Order No. 2861603• 4 outputs• 24 V DC, 500 mA• 3-wire connection• 12.2 mm design width• 4 outputs• 12 - 253 V AC, 1 A• 3-wire connection• 48.8 mm design width• 8 outputs• 24 V DC, 500 mA• Single-wire connection• 12.2 mm design width• 8 outputs• 24 V DC, 500 mA• 4-wire connection• 48.8 mm design width• 8 outputs• 24 V DC, 2 A• 4-wire connection• 48.8 mm design width8 channels 16 channels 16 channels 32 channelsIB IL 24 DO 8-NPN-PACIB IL 24 DO 16-PACIB IL 24 DO 32/HD-PACIB IL 24 DO 32/HD-NPN-PACOrder No. 2863546 Order No. 2861292 Order No. 2862822 Order No. 2878340• 8 outputs• 24 V DC, 1 A• 4-wire connection• NPN-wired• 48.8 mm design width• 16 outputs• 24 V DC, 500 mA• 3-wire connection• 48.8 mm design width• 32 outputs• 24 V DC, 500 mA• Single-wire connection• 48.8 mm design width• 32 outputs• 24 V DC, 500 mA• Single-wire connection• NPN-wired• 48.8 mm design widthPHOENIX CONTACT 29


Relay terminals1 channel 1 channel 2 channels 4 channels 4 channelsIB IL 24/230 DOR1/W-PACIB IL 24/230 DOR1/W-PC-PACIB IL 24/48 DOR2/W-PACIB IL 24/230 DOR4/W-PACIB IL 24/230 DOR4/W-PC-PACOrder No. 2861881 Order No. 2862178 Order No. 2863119 Order No. 2861878 Order No. 2862181• 1 SPDT relay contact• Gold contacts(<strong>for</strong> switching lamploads)• 5 - 253 V AC, 3 A• 12.2 mm design width• 1 SPDT relay contact• AgSnO 2 contacts(<strong>for</strong> switching inductiveand capacitive loads)• 5 - 253 V AC, 2.6 A• 12.2 mm design width• 2 SPDT relay contacts• 5 - 50 V DC• 5 - 120 V AC, 2 A• 12.2 mm design width• 4 SPDT relay contacts• Gold contacts(<strong>for</strong> switching lamploads)• 5 - 253 V AC, 3 A• 48.8 mm design width• 4 SPDT relay contacts• AgSnO 2 contacts(<strong>for</strong> switching inductiveand capacitive loads)• 5 - 253 V AC, 3 A• 48.8 mm design width4 channels O<strong>the</strong>rIB IL 24/230 DOR4/HC-PACIB IL DOR LV-SET-PACOrder No. 2897716 Order No. 2861645• 4 relay contacts• 5 to 253 V AC• Max. 10 A• High inrush current• 48.8 mm design widthDistance terminals <strong>for</strong> usewith <strong>the</strong> relay outputterminals• 12.2 mm design wid<strong>the</strong>ach30 PHOENIX CONTACT


Analog input terminals2 channels 2 channels 4 channels 4 channels 4 channelsIB IL AI 2/SF-PAC IB IL AI 2-HART-PAC IB IL AI 4/U-PAC IB IL AI 4/I-PAC IB IL AI 4/EF-PACOrder No. 2861302 Order No. 2862149 Order No. 2700459 Order No. 2700458 Order No. 2878447• 2 inputs• 0 - 20 mA, 4 - 20 mA,±20 mA, 0 - 10 V, ±10 V• 16 bits• 12.2 mm design width• 2 electrically isolatedinputs <strong>for</strong> HARTcompatiblesensors• With sensor supply• 16 bits• 48.8 mm design width• 4 differential inputs(voltage)• 0 - 10 V, ±10 V• 13 bits• 12.2 mm design width• 4 differential inputs(current)• 0 - 20 mA, 4 - 20 mA• 13 bits• 12.2 mm design width• 4 differential inputs withinitiator supply• 0 - 20 mA, 4 - 20 mA, ±20 mA,0 - 10 V, ±10 V, 0 - 5 V, ±5 V• Overload protection (mA)• Bus synchronous (≥ 1 ms)• 16 bits• 48.8 mm design width8 channels 8 channelsIB IL AI 8/SF-PACIB IL AI 8/IS-PACOrder No. 2861412 Order No. 2861661• 8 inputs• 0 - 20 mA, 4 - 20 mA,±20 mA, 0 - 40 mA, ±40 mA,0 - 5 V, ±5 V, 0 - 10 V, ±10 V,0 - 25 V, ±25 V,0 - 50 V• Multiplex mode• 16 bits• 8 inputs with initiatorsupply• 0 - 20 mA, 4 - 20 mA, ±20 mA,0 - 40 mA, ±40 mA• Multiplex mode• 16 bits• 48.8 mm design widthAnalog output terminals1 channel 1 channel 2 channels 2 channels 4/8 channelsIB IL AO 1/SF-PAC IB IL AO 1/U/SF-PAC IB IL AO 2/SF-PAC IB IL AO 2/U/BP-PACIB IL AO 4/8/U/BP-PACOrder No. 2861315 Order No. 2861399 Order No. 2863083 Order No. 2861467 Order No. 2878036• 1 output• 0 - 20 mA, 4 - 20 mA,0 - 10 V• 500 Ω load• Short-circuit-proof• 16 bits• 24.4 mm design width• 1 output• 0 - 10 V• Short-circuit-proof• 16 bits• 12.2 mm design width• 2 outputs• 0 - 20 mA, 4 - 20 mA, 0 - 10V• 500 Ω load• 16 bits• 48.8 mm design width• 2 outputs• 0 - 10 V, ±10 V• 16 bits• 12.2 mm design width• 4 or 8 outputs• 0 - 5 V, ±5 V, 0 - 10 V, ±10 V• Short-circuit-proof• 16 bits• Defined (fast) shutdownbehavior• 48.8 mm design widthPHOENIX CONTACT 31


Temperature measurement terminals1 channel 2 channels 2 channels 4/8 channels 4/8 channelsIB IL 24 TC-PACIB IL TEMP 2 RTD-PACIB IL TEMP 2 UTH-PACIB IL TEMP 4/8 RTD-PACIB IL TEMP 4/8 RTD/EF-PACOrder No. 2861360 Order No. 2861328 Order No. 2861386 Order No. 2863915 Order No. 2897402• <strong>The</strong>rmistor terminal <strong>for</strong>evaluating motor PTC<strong>the</strong>rmistors• 1 input• 1 output• 12.2 mm design width• 2 inputs <strong>for</strong> resistancetemperature detectors• 16 bits• 12.2 mm design width• 2 inputs <strong>for</strong><strong>the</strong>rmocouples• 16 bits• 12.2 mm design width4 channels 6 channels 8 channels• 4 or 8 inputs <strong>for</strong> resistancetemperature detectorswith 2/3-wire connection• 48.8 mm design width• 4 or 8 inputs <strong>for</strong> resistancetemperature detectorswith 4-wire connection• 16 bits• Extremely precise• 48.8 mm design widthIB IL TEMP 4 UTHHEI 1 DO 4-PACIB IL TEMP 6 RTDHEI 1 DO 6-PACIB IL TEMP 8 UTHHEI 1 DO 8-PACOrder No. 2819707 Order No. 2819684 Order No. 2819697• Extension modules <strong>for</strong>IB IL TEMPCON 300…• 4 inputs <strong>for</strong><strong>the</strong>rmocouples• Total current measurementof heating elements• 4 outputs• 16 bits• 48.8 mm design width• Extension modules <strong>for</strong>IB IL TEMPCON 300…• 6 inputs <strong>for</strong> resistance<strong>the</strong>rmometers• Total current measurementof heating elements• 6 outputs• 16 bits• 48.8 mm design width• Extension modules <strong>for</strong>IB IL TEMPCON 300…• 8 inputs <strong>for</strong><strong>the</strong>rmocouples• Total current measurementof heating elements• 8 outputs• 16 bits• 48.8 mm design widthStrain gauge measurement terminals2 channels 2 channels 1 channel Calibration setIB IL SGI 2/F-PAC IB IL SGI 2/P-PAC IB IL SGI 1/CAL IB IL SGI EU CALSETOrder No. 2878638 Order No. 2884907 Order No. 2700064 Order No. 2700165• 2 inputs <strong>for</strong> strain gauges• Extremely fast (1 ms)• Bus-synchronous• 16 bits• 48.8 mm design width• 2 inputs <strong>for</strong> strain gauges• Extremely precise• RS-485 interface <strong>for</strong>external display• 48.8 mm design width• 1 input <strong>for</strong> strain gauge• Can be verified by EC typeapproval• Up to 3000 pitch values• Serial interface• 48.8 mm design width• Calibration set,approval-related• Accessories <strong>for</strong>IB IL SGI 1/CAL32 PHOENIX CONTACT


Machine Edition (ME)DI DI DO DOIB IL 24 DI 4-ME IB IL 24 DI 16-ME IB IL 24 DO 4-ME IB IL 24 DO 16-MEOrder No. 2863928 Order No. 2897156 Order No. 2863931 Order No. 2897253• 4 inputs• 24 V DC• 3-wire connection• Short connector• 12.2 mm design width• 4 pcs. per pack• 16 inputs• 24 V DC• 3-wire connection• Short consecutively numberedconnectors• 48.8 mm design width• 4 pcs. per pack• 4 outputs• 24 V DC, 500 mA• 3-wire connection• Short connector• 12.2 mm design width• 4 pcs. per pack• 16 outputs• 24 V DC, 500 mA• 3-wire connection• Short consecutively numberedconnectors• 48.8 mm design width• 4 pcs. per packAIAOIB IL AI 2/SF-MEIB IL AO 2/U/BP-MEOrder No. 2863944 Order No. 2863957• 2 inputs• 0 - 20 mA, 4 - 20 mA, ±20 mA,0 - 10 V, ±10 V• 12 bits• Without shield connection• 12.2 mm design width• 2 outputs• 0 - 10 V, ±10 V• 12 bits• Without shield connection• 12.2 mm design widthIntrinsically safe <strong>Inline</strong> terminals (Ex-i)Power terminal DIO AIO TEMP RTD/TCIB IL EX-IS PWR IN-PACIB IL EX-IS DIO 4/NAM-PACIB IL EX-IS AIO 4/EF-PACIB IL EX-IS TEMP 4 RTD/TC-PACOrder No. 2869910 Order No. 2869911 Order No. 2869912 Order No. 2869913• 24 V DC (U Ex )• 1000 mA (max.) at U Ex• Diagnostic LEDs• Electronic overload protection• 48.8 mm design width• 4 configurable I/O channels• NAMUR sensors supported(EN 60947-5-6)• Single-channel diagnostics• 48.8 mm design width• 4 configurable I/O channels• Input: 0 - 10 V, 4 - 20 mA• Output: 0 - 20 mA, 4 - 20 mA• Module-based electrical isolation• Single-channel diagnostics• 48.8 mm design width• 4 configurable I/O channels• RTD inputs: 2 and 3-wire,Pt, Ni (DIN 100, 200, 500, 1000)• TC inputs: J, K, E, R, S, T• Module-based electrical isolation• Single-channel diagnostics• 48.8 mm design widthPHOENIX CONTACT 33


Communication terminalsBranch terminalsIBS IL 24 RB-T-PAC IBS IL 24 RB-LK IB IL 24 FLM-PACIB IL 24 FLM MULTI-IB IL 24 LSKIP-PACPACOrder No. 2861441 Order No. 2878117 Order No. 2736903 Order No. 2737009 Order No. 2897457• INTERBUS remote busbranch• 12.2 mm design width• INTERBUS remote busbranch• Fiber optic connection• 24.4 mm design widthBranch terminal <strong>for</strong>connecting a FieldlineModular M8 or M12 localbus at <strong>the</strong> end of an <strong>Inline</strong>station• 12.2 mm design widthBranch terminal <strong>for</strong>connecting a Fieldline ModularM8 local bus at any point inan <strong>Inline</strong> station• 12.2 mm design width<strong>Inline</strong> local bus extensionterminal• Can be used withIB IL 24 FLM-PAC• 48.8 mm design widthSerial interfaceIO-LinkIB IL RS 232-PACIB IL RS 232-PRO-PACIB IL RS 485/422-PACIB IL RS 485/422-PRO-PACIB IL 24 IOL 4 DI 12-PACOrder No. 2861357 Order No. 2878722 Order No. 2861933 Order No. 2863627 Order No. 2692717• 1 serial input and outputchannel in V.24 (RS-232)<strong>for</strong>mat• Max. transmission speedof 38.4 kbaud• 24.4 mm design width• 1 serial input and outputchannel in V.24 (RS-232)<strong>for</strong>mat• Process datacommunication only• Max. transmission speedof 38.4 kbaud• 24.4 mm design width• 1 serial input and outputchannel in RS-485/RS-422<strong>for</strong>mat• Max. transmission speedof 38.4 kbaud• 24.4 mm design width• 1 serial input and outputchannel in RS-485/RS-422<strong>for</strong>mat• Process datacommunication only• Max. transmission speedof 38.4 kbaud• 24.4 mm design widthIF <strong>system</strong> bus master CAN master PROFIBUS master AS-i master• 4 IO-Link channels• 12 digital inputs,24 V DC• 48.8 mm design widthIB IL IFS-MA-PAC IB IL CAN-MA-PAC IB IL PB-MA-PAC ASI MA IL UNIOrder No. 2692720 Order No. 2700196 Order No. 2700630 Order No. 2736628• Integration of up to 8 EMMand EEM modules• Serial interface (S-port) incl.memory stick• Up to 31 measured valuesand 16 manipulatedvariables• 24.4 mm design width• CAN 2.0A and CAN 2.0B• Transmission speed of10 kbps to 1 Mbps• Serial interface (S-port) incl.memory stick• 12.2 mm design width• PROFIBUS DP V0master/slave• Transmission speed of12 Mbps• Serial interfaceincl. memory stick• 48.8 mm design width• <strong>Inline</strong>/AS-i master,universal <strong>for</strong> all buscouplers• 69.2 mm design width34 PHOENIX CONTACT


Communication terminalsDALI terminalsEnOcean wireless receiverIB IL DALI/PWR-PAC IB IL DALI-PAC SRC-RS485 EVCOrder No. 2897813 Order No. 2897910 Order No. 2897237• Single-channel DALImaster• Integrated DALI powersupply unit• Safe electrical isolation• 61 mm design width• Single-channel DALImaster• Extension <strong>for</strong> IB IL DALI/PWR-PAC• 12.2 mm design widthTerminals <strong>for</strong> open and closed-loop <strong>control</strong>EnOcean wireless receiver<strong>for</strong> connecting toIB IL RS 485/422-PRO-PACPositioning terminals Counters PWM terminalIB IL SSI-PAC IB IL INC-PAC IB IL CNT-PAC IB IL DI 8/S0-PAC IB IL PWM/2-PACOrder No. 2861865 Order No. 2861849 Order No. 2861852 Order No. 2897020 Order No. 2861632• Single-axis point-to-point<strong>control</strong> <strong>for</strong> absoluteencoders with SSI interface• Rapid motion/creepingmotion principle• 48.8 mm design width• Single-axis point-to-point<strong>control</strong> <strong>for</strong> incrementalencoders• Rapid motion/creepingmotion principle• 48.8 mm design width• 1 counter input• 1 <strong>control</strong> input• 1 output• Max. counting frequency of100 kHz• 24-bit binary counter• Pulse generator• 24.4 mm design width• 8 S0 counter inputs/digitalinputs• 48.8 mm design width• Pulse width modulation• 2 channels• Pulse/direction interface <strong>for</strong><strong>control</strong>ling step motorpower sections• Max. 50 kHz (5 V)• Max. 500 Hz (24 V)• 24.4 mm design widthPosition detection terminalsIB IL SSI-IN-PAC IB IL INC-IN-PACIB IL IMPULSE-IN-PACOrder No. 2819574 Order No. 2861755 Order No. 2861768• Reads positions of absoluteencoders with SSI interface• 12.2 mm design width• Reads positions ofincremental encoders• 24.4 mm design width• Reads positions frommagnetostrictive lengthmeasuring <strong>system</strong>s withstart/stop interface• 12.2 mm design widthPHOENIX CONTACT 35


sTerminals <strong>for</strong> open and closed-loop <strong>control</strong>Temperature <strong>control</strong>lersIB IL TEMPCON 300UTH-PACIB IL TEMPCON 300UTH-B-PACIB IL TEMPCON 300RTD-PACIB IL TEMPCON 300RTD-B-PACOrder No. 2819671 Order No. 2819613 Order No. 2819668 Order No. 2819590• Multi-channel temperature<strong>control</strong>ler• Supports modularexpansion• 8 - 30 closed-loop <strong>control</strong>circuits• <strong>The</strong>rmocouple• 48.8 mm design widthPower-level terminals• Multi-channel temperature<strong>control</strong>ler• Compact• 4 closed-loop <strong>control</strong>circuits• <strong>The</strong>rmocouple• 48.8 mm design width• Multi-channel temperature<strong>control</strong>ler• Supports modularexpansion• 6 - 30 closed-loop <strong>control</strong>circuits• Resistance <strong>the</strong>rmometer• 48.8 mm design width• Multi-channel temperature<strong>control</strong>ler• Compact• 4 closed-loop <strong>control</strong>circuits• Resistance <strong>the</strong>rmometer• 48.8 mm design widthServo amplifiers Direct starters Reversing starterIB IL DC AR 48/10AIB IL EC AR 48/10A-IB IL 400 MLR 1-8A IB IL 400 ELR 1-3A IB IL 400 ELR R-3APACOrder No. 2819286 Order No. 2819587 Order No. 2727365 Order No. 2727352 Order No. 2727378• Servo amplifier <strong>for</strong> a DCmotor with brushgears• Speed and torque <strong>control</strong>• Max. 48 V/10 A• 48.8 mm design width• Servo amplifier <strong>for</strong> a DCmotor with or withoutbrushgears• Position, speed, andtorque <strong>control</strong>• Max. 48 V/10 A• 97.6 mm design width• Electromechanical loadrelay• Single-channel directstarter• Up to 3.7 KW/400 V AC• 63 mm design width• Electronic load relay• Single-channel directstarter• Up to 1.5 KW/400 V AC• 63 mm design width• Electronic load relay• Single-channel reversingstarter• Up to 1.5 KW/400 V AC• 63 mm design widthBrake moduleIB IL 24 BR/DCIB IL 400 BROrder No. 2742036 Order No. 2727394• Electronic brake switch• 5 V DC ... 31 V DCconnection voltage• Electronic brake switch• 20 V AC ... 440 V AC or12 V DC ... 440 V DCconnection voltage36 PHOENIX CONTACT


Power-level terminals – AccessoriesIBS HVO IB IL 400 CN-PWR-IN IB IL 400 CN-BRG IB IL 400 CN-COVGMVSTBW 2,5 HV/4-ST-7,62 NZILOrder No. 2836052 Order No. 2836078 Order No. 2836081 Order No. 2860947 Order No. 1893957• Hand-held operator panel • 400 V AC power connector • 400 V AC power bridge • Cover <strong>for</strong> power routing • Motor circuit connectorSafety terminalsSafe logic modules <strong>for</strong> SafetyBridge technologyIB IL 24 LPSDO 8-PACIB IL 24 LPSDO 8 V2-PACOrder No. 2916024 Order No. 2700606• Connection to 3 safe input modules• 4 safety-related two-channel inputseach or 8 safety-related single-channelinputs each• 6 KB logic memory• Max. 2 A (observe derating)• Max. safety category 4 acc. toEN 954-1, PL e acc. toEN ISO 13849-1, and SIL 3 acc. toIEC 61508 (EN IEC 62061)• 48.8 mm design width• Connection to 5 safe I/O modules• 4 safety-related two-channel outputseach or 8 safety-related single-channeloutputs each• 24 KB logic memory• Max. 2 A (observe derating)• Max. safety category 4 acc. toEN 954-1, PL e acc. toEN ISO 13849-1, and SIL 3 acc. toIEC 61508 (EN IEC 62061)• 48.8 mm design widthSafe I/O modules <strong>for</strong> SafetyBridge technology, INTERBUS-Safety, and PROFIsafeIB IL 24 PSDI 8-PAC IB IL 24 PSDO 8-PAC IB IL 24 PSDOR 4-PAC IB IL 24 PSDO 4/4-PACOrder No. 2985688 Order No. 2985631 Order No. 2985864 Order No. 2916493• 4 safety-related two-channel inputseach or 8 safety-related single-channelinputs each• 2 clock outputs <strong>for</strong> supplying inputsUT1 and UT2• Max. safety category 4 acc. toEN 954-1, PL e acc. toEN ISO 13849-1, and SIL 3 acc. toIEC 61508 (EN IEC 62061)• 48.8 mm design width• 4 safety-related two-channel outputseach or 8 safety-related single-channeloutputs each• Max. 2 A (observe derating)• Max. safety category 4 acc. toEN 954-1, PL e acc. toEN ISO 13849-1, and SIL 3 acc. toIEC 61508 (EN IEC 62061)• 48.8 mm design width• 2 safety-related two-channel relays or4 safety-related single-channel relays(two floating contacts each)• 2 readback inputs <strong>for</strong> recordingexternal circuit breakers• 2 clock outputs <strong>for</strong> supplying <strong>the</strong>readback inputs• Max. safety category 4 acc. toEN 954-1, PL e acc. toEN ISO 13849-1, and SIL 3 acc. toIEC 61508 (EN IEC 62061)• 73 mm design width• 4 safe positive switching and4 safe negative switching digitaloutputs• Max. 2 A per output (observederating)• Max. safety category 4 acc. toEN 954-1, PL e acc. toEN ISO 13849-1, and SIL 3 acc. toIEC 61508 (EN IEC 62061)• 48.8 mm design widthPHOENIX CONTACT 37


Wireless IOILB BT ADIO MUX-OMNI ILB BT ADIO MUX-PANEL ILB BT ADIO 2/2/16/16Order No. 2884208 Order No. 2884509 Order No. 2884282• Wireless point-to-point transmission• Omnidirectional antenna• Bluetooth 1.2 (16 dBm transmissionpower)• 16 digital inputs• 16 digital outputs• 2 analog inputs• 2 analog outputs• 95 mm design width• Wireless point-to-point transmission• Panel directional wireless antenna• Bluetooth 1.2 (12 dBm transmissionpower)• 16 digital inputs• 16 digital outputs• 2 analog inputs• 2 analog outputs• 95 mm design width• Wireless IO device• Bluetooth 1.2 (16 dBm transmissionpower, adjustable)• Wireless access viaFL BT MOD IO AP (Order No. 2884758)or FLM BT BS 3 (Order No. 2736770)• 16 digital inputs• 16 digital outputs• 2 analog inputs• 2 analog outputs• 95 mm design width38 PHOENIX CONTACT


Accessories <strong>for</strong> <strong>Inline</strong> Modular IO and <strong>Inline</strong> Block IOFLKM 14-PA-INLINE/DIO8FLKM 14-PA-INLINE/IN8FLKM14-PA-INLINE/IN16FLKM14-PA-INLINE/32PSM-SET-FSMA/4-KTOrder No. 2900889 Order No. 2304128 Order No. 2302751 Order No. 2302777 Order No. 2799720VARIOFACE front adapter <strong>for</strong>8-channel <strong>Inline</strong> HD modulesFLKM14-PA-INLINE/OUT8FLKM14-PA-INLINE/OUT16PSM-SET-FSMA/4-HCSOrder No. 2304131 Order No. 2302764 Order No. 2799487VARIOFACE front adapter <strong>for</strong>8-channel <strong>Inline</strong> modulesVARIOFACE front adapter <strong>for</strong>16-channel <strong>Inline</strong> modulesVARIOFACE front adapter <strong>for</strong>32-channel <strong>Inline</strong> modulesFSMA connector <strong>for</strong>INTERBUS fiber opticsIBS DSUB 9/LSUBCON 9/F-SHSUBCON-PLUS-PROFIB/...IB IL FIELD 2ESL 62X10Order No. 2758473 Order No. 2761499 See INTERFACE catalog Order No. 2727501 Order No. 809492IBS DSUB 9/CSUBCON 9/M-SHSUBCON-PLUS-CAN/...IB IL FIELD 8ESL 62X46Order No. 2758486 Order No. 2761509 See INTERFACE catalog Order No. 2727515 Order No. 8095029-pos. D-SUB connectorsSUBCON D-SUBconnectors <strong>for</strong> INTERBUSSUBCON connectors <strong>for</strong>PROFIBUS and CAN<strong>Inline</strong> labeling fieldsLabeling sheets <strong>for</strong> laserprinterZBFM 6-... CLIPFIX 35-5 CLIPFIX 35 E/AL-NS 35 I-L ATP GNSee CLIPLINE catalog Order No. 3022276 Order No. 3022218 Order No. 1201662 Order No. 2740850Zack marker strip labeling Standard end clamp End clamp <strong>for</strong> CANopen andDeviceNet bus couplersEnd clamp <strong>for</strong> use in <strong>the</strong>event of vibrationsEnd cover plateIL CP SI 5x20 6,3AT ZFK-BW 2-5Order No. 2742683 Order No. 2726104 Order No. 3024287Keying profile• Pcs./Pkt.: 17 profiles with6 pins eachReplacement fuse <strong>for</strong> <strong>Inline</strong>power and segment terminals• Pcs./Pkt.: 10 pcs.Spring-cage tool <strong>for</strong> removing<strong>the</strong> shield connection clamp(2-pos.)PHOENIX CONTACT 39


Fur<strong>the</strong>r in<strong>for</strong>mation on <strong>the</strong> productspresented here and on <strong>the</strong> world of solutionsfrom <strong>Phoenix</strong> <strong>Contact</strong> can be found atwww.phoenixcontact.net/catalogIndustrial Connection Technology,Marking Systems and Mounting MaterialCLIPLINEConnection Technology <strong>for</strong> FieldDevices and Field CablingPLUSCONOr contact us directly.Device Connection Technologyand Electronic HousingsCOMBICONPHOENIX CONTACT GmbH & Co. KG32823 Blomberg, GermanyPhone: +49 5235 3-00Fax: +49 5235 3-4 12 00www.phoenixcontact.comComponents and SystemsAUTOMATIONPower and Signal QualityTRABTECHSignal Converters, Switching Devices,Power Supply UnitsINTERFACEMNR 52003508/01.02.2011-02 Printed in Germany © PHOENIX CONTACT 2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!