11.07.2015 Views

FANS FOR THE SMOKE EXTRACTION - Sodeca

FANS FOR THE SMOKE EXTRACTION - Sodeca

FANS FOR THE SMOKE EXTRACTION - Sodeca

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ACCESSORIESElectrical starter panel and protection fromoverload and short-circuits of fans withGMM three-phase motor, with rotary controlsFeatures:• On/Off by means of a rotary control with the possibility ofblocking with three locks• Incorporates adjustable thermal relay for protection fromoverload and short-circuit• For assembly on the surface, IP-55 protectionFor fan with three-phase motor 400VModelCurrentof regulation (A)Power motor3x400V (kW)GMM-01-1/400 1.6-2.5 0.75GMM-01-2/400 2.5-4 1.10 1.50GMM-01-3/400 4-6.3 2.20GMM-01-5,5/400 6.3-10 3.00 4.00GMM-01-7,5/400 10-16 5.50GMM-01-10/400 16-20 7.50GMM-01-15/400 20-25 11.00GMM-01-20/400 25-32 15.00AETElectrical starter panel, star / triangle, and protection of fans with three-phase motor,with On/Off buttonsFeatures:• On/Off by button• Display of condition by means of luminous pilot lights• Incorporates adjustable thermal relay for protectionof the motorModelFor fan with three-phase motor 230V/400V.Power supply 3x230VCurrent regulationof thermal relay (A)Power motor3x230/400V (kW)AET-01-3/230 4-6.3 2.2AET-01-4/230 5-8 3.0AET-01-5,5/230 7-10 4.0AET-01-7,5/230 12-18 5.5AET-01-10/230 12-18 7.5AET-01-15/230 18-26 11.0AET-01-20/230 24-36 15.0AET-01-25/230 28-40 18.5AET-02-30/230 34-50 22.0AET-02-40/230 45-65 30.0AET-02-50/230 63-85 37.0Model• Fully cabled• Metal box for assembly on the surface, IP-65protectionFor fan with three-phase motor 400V/690V.Power 3x400V+NCurrent regulationof thermal relay (A)Power motor3x400/690V (kW)AET-01-5,5/400 4-6,3 4AET-01-7,5/400 5-8 5,5AET-01-10/400 7-10 7,5AET-01-15/400 12-18 11AET-01-20/400 12-18 15AET-02-30/400 18-26 18,5/22,0AET-02-40/400 28-40 30AET-02-50/400 34-50 37AET-02-60/400 45-65 45AET-02-75/400 45-65 55ADElectrical starter panel and protection of fans withthree-phase motor, with two DAHLANDER speedsFeatures:• Switch for selecting speed (1-0-2), Low-Off-High.• Display of condition by means of luminous pilot lights• Incorporates adjustable thermal relay for protection of the motor• Fully cabled• Metal plate for assembly on the surface, IP-65 protectionFor fan with three-phase 400V Dahlander motor.Power 3x400V+NModelCurrent regulation of thermal relayHigh speed (A) Low speed (A)AD-01-2,5-1/400 1.6-2.5 0.63-1AD-01-4-1,6/400 2.5-4 1-1.6AD-01-4-2,5/400 2.5-4 1.6-2.5AD-01-6-2,5/400 4-6 1.6-2.5AD-01-9-2,5/400 6-9 1.6-2.5AD-01-9-4/400 6-9 2.5-4AD-02-13-4/400 9-13 2.5-4AD-02-18-6/400 12-18 4-6AD-02-18-9/400 12-18 6-9AD-02-26-9/400 18-26 6-9AD-02-36-9/400 24-36 6-9AD-02-36-13/400 24-36 9-13AD-02-40-18/400 28-40 12-18PLAPlastic backdraughtlouvres.Features:• The backdraught louvre is adapted directly to the wallwhere the fan is mounted.• Opening through overpressure due to airflow• Closed when the fan is on standby• Made from plastic• Maximum recommended speed 12m/sec for models 80,90 and 100ModelMeasurementsC ØD E FPL-20 240 28 5.2 193 167PL-25 294 26 5 232 232PL-31 347 26 5 276 276PL-35 397 26 5 310 310PL-40 459 26 5 364 364PL-45 501 26 5 395 395PL-50 549 31 5 445 445PL-56 605 28 5 522 522PL-63 696 31 5 626 626PL-71 760 40 5 692 692PL-80 840 40 5 772 772PL-90 940 40 5 872 87PL-100 1040 40 5 972 972171

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!