KIT SOBREPRESIÓNThe system of pressurisation of staircases, escape routes or of confinement makes it possible tocontrol the airflow automatically and to maintain a differential pressure of 50 Pa in a single stage,according to standard UNE EN 12101-6-2006.STAIRWELL KIT SOBREPRESIÓNFor three-phase equipmentSTAIRWELL KIT SOBREPRESIÓN• Stairwell overpressure kit made up of control panel (BOXPRES KIT) and outlet units (CJHCH orCJBD) , for the pressurisation of the stairwells and escape routes. It also available for singlephaseequipment NEOLINEO AND CJBC.KIT SOBREPRESIÓN WITH RESERVE FAN• Overpressure kit with reserve fan, made up of control panel (BOXPRES KIT II), which incorporates asystem of automatic switching to keep the overpressure in the case of a stop by the main fan andTWIN or CJHCH/DUPLEX air outlet units with reserve fan.BOXPRESSTAIRWELL KIT SOBREPRESIÓNFor single-phase equipment· Easy to install· Compact and self-sufficient solution· Preventive maintenance· Easy starting· Safe and functional installation• The proper operation of the pressurisation systems depends not only on correct design but also onthe proper regulation carried out by the system with the result that it is of vital importance to havecalibrated and highly-precise regulation elements which make it possible to have the two situations inthe case of fire, in a rapid and stable manner.• The BOXPRES control panel, apart from satisfying the most demanding requirements, simplifies thework of the installer to the greatest possible extent.KIT SOBREPRESIÓN WITHRESERVE FANIncludes:• Frequency varier programmed to 50 Pa• Differential pressure probe• Magneto thermal• Line LED and fault• Check buttonBOXPRES is a piece of equipment with all its interconnections made and tested• Ready to work and carry out its duties on the pressure control of the installation.• Possibility of checking the installation so as to prevent faults• Only the power cable, the impulsion fan and the fire signal should be connected.The panels for single-phase equipment include:• Frequency voltage programmed to 50 Pa• Differential pressure probe external to the equipment.Order codeKIT SOBREPRESIÓN 7.100Kit sobrepresión: Overpressureset for staircasesKit sobrepresión II: Overpressureset with reserve fanMaximumAirflow162
KIT SOBREPRESIÓNTechnical characteristicsModelPowersupplyOutputOutlet unitAirflow(m 3 /h)Irradiatedsoundlevel * dB(A)KIT SOBREPRESION-1060-LED 230 Vac II 230 Vac II NEOLINEO-200 1060 38KIT SOBREPRESION-2300-LED 230 Vac II 230 Vac II NEOLINEO-315 2300 47KIT SOBREPRESION-2880-LED 230 Vac II 230 Vac II CJBC-2828-6M 1/3 2880 61KIT SOBREPRESION-7100-LED 230 Vac II 230 Vac III CJHCH-45-4T-0,5 7100 55KIT SOBREPRESION-7800-LED 230 Vac II 230 Vac III CJBD-3333-6T-1,5 7800 55KIT SOBREPRESION-12900-LED 230 Vac II 230 Vac III CJHCH-56-4T-1 12900 60KIT SOBREPRESION-17000-LED 230 Vac II 230 Vac III CJHCH-63-4T-1,5 17000 61KIT SOBREPRESION-7100-BOX 400 Vac III 400 Vac III CJHCH-45-4T-0,5 7100 55KIT SOBREPRESION-7800-BOX 400 Vac III 400 Vac III CJBD-3333-6T-1,5 7800 55KIT SOBREPRESION-12900-BOX 400 Vac III 400 Vac III CJHCH-56-4T-1 12900 60KIT SOBREPRESION-17000-BOX 400 Vac III 400 Vac III CJHCH-63-4T-1,5 17000 61KIT SOBREPRESION II-6240-BOX 400 Vac III 400 Vac III TWIN-12/12-6T-1,5 6240 55KIT SOBREPRESION II-9520-BOX 400 Vac III 400 Vac III TWIN-15/15-6T-3 9520 54KIT SOBREPRESION II-12900-BOX 400 Vac III 400 Vac III CJHCH/DUPLEX-56-4T-1-H 12900 60KIT SOBREPRESION II-17000-BOX 400 Vac III 400 Vac III CJHCH/DUPLEX-63-4T-1,5-H 17000 61SONDA TPDA SI-PRESIÓN c/DISPLAYSONDA TPDA 984M.523 P04SONDA TPDA 984M.523 P14 LEDBOXPRES KIT-3A 230Vac 230 Vac II 230 Vac IIBOXPRES KIT-10A 230Vac 230 Vac II 230 Vac IIBOXPRES KIT-0,75KW 230Vac 230 Vac II 230 Vac IIIBOXPRES KIT-1,5KW 230Vac 230 Vac II 230 Vac IIIBOXPRES KIT-0,75KW 400Vac 400 Vac III 400 Vac IIIBOXPRES KIT-1,5KW 400Vac 400 Vac III 400 Vac IIIBOXPRES KIT-2,2KW 400Vac 400 Vac III 400 Vac IIIBOXPRES KIT II - 1,5KW 400Vac 400 Vac III 400 Vac IIIBOXPRES KIT II - 2,2KW 400Vac 400 Vac III 400 Vac IIIDimensions in mmCJHCHCJBDModel A C D1CJHCH-40/45/50 700 550 565CJHCH-56/63 825 550 690Model Equiv. A B C E D1xD2 G1 L KinchesCJBD-3333 12/12 650 650 700 92 556X606 379 358 400163
- Page 112 and 113: TCR/RCJTCR/R400ºC/2h centrifugal f
- Page 114 and 115: TCR/R CJTCR/RDimensions in mmModel
- Page 116 and 117: TCR/R CJTCR/RCharacteristic curvesQ
- Page 118 and 119: TCMP CJMPTechnical characteristicsM
- Page 120 and 121: TCMP CJMPDimensions in mmStandard s
- Page 122 and 123: TCMP CJMPCharacteristic curvesQ = A
- Page 124 and 125: CJTX-CTechnical characteristicsMode
- Page 126 and 127: CJTX-CDimensions in mmStandard supp
- Page 128 and 129: CJTX-CCharacteristic curvesQ = Airf
- Page 130 and 131: CJTX-CCharacteristic curvesQ = Airf
- Page 132 and 133: CJSX400ºC/2h belt-driven extractio
- Page 134 and 135: CJSXCharacteristic curvesQ = Airflo
- Page 136 and 137: CJSXCharacteristic curvesQ = Airflo
- Page 138 and 139: CSXCJSRX400ºC/2h centrifugal belt-
- Page 141 and 142: CSX CJSRXDimensions in mmStandard s
- Page 143 and 144: CSX CJSRXCharacteristic curvesQ = A
- Page 145 and 146: CSX CJSRXCharacteristic curvesQ = A
- Page 147 and 148: CSX CJSRXCharacteristic curvesQ = A
- Page 149 and 150: CJLINETechnical characteristicsMode
- Page 151 and 152: CJLINECharacteristic curvesQ = Airf
- Page 153 and 154: CJECExtraction units with large hat
- Page 155 and 156: CJECCharacteristic curvesQ = Airflo
- Page 157 and 158: CHT CVTTechnical characteristicsMod
- Page 159 and 160: CHT CVTCharacteristic curvesQ = Air
- Page 161: CHT CVTCharacteristic curvesQ = Air
- Page 165 and 166: KIT SOBREPRESIÓNBOXPRESS KIT SOBRE
- Page 167 and 168: ACCESSORIESINTIATCABLE BOXC2VRMOn/O
- Page 169: ACCESSORIESARSoft starters for thre
- Page 172 and 173: ACCESSORIESPAluminium backdraughtlo
- Page 174 and 175: ACCESSORIESBACDouble, elastic coupl
- Page 176: ACCESSORIESTEJOutside covers.Featur
- Page 179 and 180: 179
- Page 181 and 182: PERPIGNAFRANCEPUIGCERDÀRIPOLLFIGUE
KIT SOBREPRESIÓNThe system of pressurisation of staircases, escape routes or of confinement makes it possible tocontrol the airflow automatically and to maintain a differential pressure of 50 Pa in a single stage,according to standard UNE EN 12101-6-2006.STAIRWELL KIT SOBREPRESIÓNFor three-phase equipmentSTAIRWELL KIT SOBREPRESIÓN• Stairwell overpressure kit made up of control panel (BOXPRES KIT) and outlet units (CJHCH orCJBD) , for the pressurisation of the stairwells and escape routes. It also available for singlephaseequipment NEOLINEO AND CJBC.KIT SOBREPRESIÓN WITH RESERVE FAN• Overpressure kit with reserve fan, made up of control panel (BOXPRES KIT II), which incorporates asystem of automatic switching to keep the overpressure in the case of a stop by the main fan andTWIN or CJHCH/DUPLEX air outlet units with reserve fan.BOXPRESSTAIRWELL KIT SOBREPRESIÓNFor single-phase equipment· Easy to install· Compact and self-sufficient solution· Preventive maintenance· Easy starting· Safe and functional installation• The proper operation of the pressurisation systems depends not only on correct design but also onthe proper regulation carried out by the system with the result that it is of vital importance to havecalibrated and highly-precise regulation elements which make it possible to have the two situations inthe case of fire, in a rapid and stable manner.• The BOXPRES control panel, apart from satisfying the most demanding requirements, simplifies thework of the installer to the greatest possible extent.KIT SOBREPRESIÓN WITHRESERVE FANIncludes:• Frequency varier programmed to 50 Pa• Differential pressure probe• Magneto thermal• Line LED and fault• Check buttonBOXPRES is a piece of equipment with all its interconnections made and tested• Ready to work and carry out its duties on the pressure control of the installation.• Possibility of checking the installation so as to prevent faults• Only the power cable, the impulsion fan and the fire signal should be connected.The panels for single-phase equipment include:• Frequency voltage programmed to 50 Pa• Differential pressure probe external to the equipment.Order codeKIT SOBREPRESIÓN 7.100Kit sobrepresión: Overpressureset for staircasesKit sobrepresión II: Overpressureset with reserve fanMaximumAirflow162