11.07.2015 Views

DEEP SEA ELECTRONICS PLC - Home Mega Global Solution

DEEP SEA ELECTRONICS PLC - Home Mega Global Solution

DEEP SEA ELECTRONICS PLC - Home Mega Global Solution

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DSE 5xxx Configuration Software ManualMagnetic Pick-up opencircuitMains FailureMains High frequencyMains High voltageMains Low frequencyMains Low voltageOil Press sender OpencircuitOil pressure low Pre-alarmOil pressure low shutdownOpen GeneratorOpen Generator PulseOpen MainsOpen Mains PulseOver current Pre-alarmOver current tripOverspeed Pre-alarmOverspeed ShutdownPre-heat (during preheattimer)Pre-heat (until end ofcranking)Pre-heat (until end ofwarming)Pre-heat (until safety on)Smoke LimitStart Delay in Progress34This output indicates that the module has detected an open circuitfailure in the Magnetic Pickup transducer circuit.This output indicates that the module has sensed that a failure of theincoming AC mains supply. This output will become active wheneverthe mains voltage or frequency goes out of limits, or if the auxiliarymains failure input active (if used) and the mains transient timer hasexpired.This output indicates that the module has sensed that the incoming ACmains supply has exceeded the frequency limit setting.This output indicates that the module has sensed that the incoming ACmains supply voltage has exceeded the voltage limit setting.This output indicates that the module has sensed that the incoming ACmains supply has fallen below the frequency setting.This output indicates that the module has sensed that the incoming ACmains supply voltage has fallen below the voltage limit setting.This output indicates that the module has detected an open circuitfailure in the Oil Pressure transducer circuit.This output indicates that a low oil pressure warning (pre-alarm) hasoccurred.This output indicates that a low oil pressure shutdown has occurred.This output source is intended to be used to control the load switchingdevice. Whenever the 52xx/53xx module selects the mains to be onload this control source will be active.This output source is intended to be used to control the load switchingdevice. Whenever the 52xx/53xx module selects the mains to be onload, this control source wil be active for the duration of the ‘Breakeropen Pulse Timer’.This output source is intended to be used to control the load switchingdevice. Whenever the 5220/5320 module selects the generator to beon load this control source will be active.This output source is intended to be used to control the load switchingdevice. Whenever the 5220/5320 module selects the generator to beon load this control source will be active for the duration of the‘Breaker open Pulse Timer’. Once this timer has expired the outputsource will once again become in-active and the 5220/5320 will issuecommands to load the generator.This output indicates that the over-current warning (pre-alarm) levelhas been reached.This output indicates that the over-current trip level been reached.This output indicates that an overspeed warning (pre-alarm) hasoccurred.This output indicates that an overspeed shutdown has occurred.The output controls the pre-heater. Pre-heat output is available for theduration of the pre-heat timer, which terminates prior to cranking.The output controls the pre-heater. As ‘Pre-heat (during preheat timer)’mode but pre-heat is also available during cranking.The output controls the pre-heater. As ‘Pre-heat (until safety on)’ butpre-heat continues to be available until the warm-up timer haselapsed.The output controls the pre-heater. As ‘Pre-heat (until end of cranking)’but pre-heat is also available while waiting for the delayed alarms tobecome active.This is used to supply a smoke-limiting signal to an ElectronicGovernor to limit smoke emissions on start-up. It is used inconjunction with the Smoke limit timer settings. Once the Timer hasexpired, the Smoke limit output will cease to operate allowing theengine to accelerate to normal running speed.This output source will be active to indicate that the 52xx/53xxmodules internal start delay timer is running. Once this timer expiresthe module with initiateit’s start sequence.DSE 5xxx Configuration software ISSUE 2 02/07/04 AM

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!