DSE 5xxx Configuration Software ManualOutput selectionFunctionOutput Not UsedAir flap RelayAudible alarmBattery High VoltageBattery Low VoltageCAN ECU errorCAN ECU failCAN data failCharge alternator failureCalling for Scheduled runClose GeneratorClose Generator PulseClose MainsClose Mains PulseCombined under & overFrequency warningCombined under & overFrequency shutdownCombined under & overvoltage warningCombined under & overvoltage shutdownCommon alarmCommon Electrical TripalarmCommon Shutdown alarmDescriptionThe output in not used.The output controls the closing of the air-flaps in an Emergency Stopor Over-speed situation.This output is intended to drive an external Klaxon or alarm indicatorand will be active upon the module triggering a warning, shutdown orelectrical trip alarm.This external alarm can be ‘muted’, without reseting the module’salarm condition by activating an auxiliary input that has beenconfigured to “Alarm Mute”.This output indicates that a Battery High Voltage alarm has occurred.This output indicates that a Battery Low Voltage alarm has occurred.The engine ECU has indicated that a warning alarm is present.The engine ECU has indicated that a shutdown alarm is present.The 52xx/53xx module is unable to communicate with the engineECU.This output indicates that a failure of the auxiliary charging alternatoron the generator has occurred.This output indicates that a scheduled run in is progress.This output source is intended to be used to control the load switchingdevice. Whenever the 52xx/53xx module selects the generator to beon load this control source will be active.This output source is intended to be used to control the load switchingdevice. Whenever the 52xx/53xx module selects the mains to be onload, this control source wil be active for the duration of the ‘BreakerClose Pulse Timer’. Once this timer has expired, the output sourcewill once again become in-active.This output source is intended to be used to control the load switchingdevice. Whenever the 5220/5320 module selects the mains to be onload this control source will be active.This output source is intended to be used to control the load switchingdevice. Whenever the 5220/5320 module selects the mains to be onload this control source wil be active for the duration of the ‘BreakerClose Pulse Timer’. Once this timer has expired the output source willonce again become in-active.The output indicates that either an under frequency or over frequencywarning has been activated.The output indicates that either an under frequency or over frequencyshutdown has been activated.The output indicates that either an under voltage or over voltagewarning has been activated.The output indicates that either an under voltage or over voltageshutdown has been activated.The output indicates that a warning, electrical trip or shutdown alarmhas been activated. Reset rules as above, depending on whether it isa Warning or a Shutdown fault.The output indicates that an electrical trip alarm has been activated.This output can only be reset by removal of the fault and by thenpressing the Stop Reset button.The output indicates that a shutdown alarm has been activated. Thisoutput can only be reset by removal of the fault and by then pressingthe Stop Resetbuton or by using an external ‘AlarmReset’ Input.32DSE 5xxx Configuration software ISSUE 2 02/07/04 AM

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!