11.07.2015 Views

DEEP SEA ELECTRONICS PLC - Home Mega Global Solution

DEEP SEA ELECTRONICS PLC - Home Mega Global Solution

DEEP SEA ELECTRONICS PLC - Home Mega Global Solution

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DSE 5xxx Configuration Software ManualNOTE:- Each Auxiliary output has the same selection choices, allowing acombination of different uses.Expansion outputs are available for 52xx/53xx type modules on a plug in Expansionmodule type 157, this provides up to 8 volt free contacts. The 157 modules are fittedwith switch labeled ‘A’ and ‘B’. With the switch in the ‘A’ position the 157 module wilrespond to signals from the 52xx/53xx module.The 53xx module will also control a second output device (Expansion B) whereby theexpansion module’s selector must be in the ‘B’ position.NOTE:- If the switch is placed in the ‘B’ position the 157 module wil ignore alsignals from the 52xx module.If expansion outputs are required to be fitted for indication purposes only, a plug inLED Expansion module type 548 is available to provide up to8 configurable LED’s (+Power On and Link Lost indicators). The 548 modules are fitted with switch labelled‘A’ and ‘B’. With the switch in the ‘A’ position the 548 module wil respond to signalsfor expansion relays 1 - 8 and iluminate the appropriate LED’s. If the switch is placedThe 53xx module will also control a second output device (Expansion B) whereby theexpansion module’s selector must be in the ‘B’ position.NOTE:- In the ‘B’ position the 548 module wil ignore al signals from the 52xxmodule.If required it is possible to use a mix of both a 157 Relay module and a 548 LEDmodule on the same 52xx/53xx Host. Expansion Relay 1 will operate in conjunctionwith Expansion LED 1 to provide volts free relay signals and LED indications of thesame function.CAUTION!:- The 157 relay status is updated twice a second. While this makes theresponse of the relays fast enough for annunciation, remote monitoring and normalsystem control it is not considered suitable for use in time critical applications such ashigh speed breaker tripping etc. If this type of function is intended, we wouldrecommend using the 52xx/53xx modules own internal relay outputs to control suchsystems.PolarityEach of the outputs can be configured as:a) Energised - Normally open relay contact which closes on activation.b) De-energised - Normally closed relay contact, which opens on activation.NOTE:- If the Expansion relays are actually control sources used for a 548 modulethen Energised = Lit and De-energised = Unlit.NOTE:- The supplied configuration file 5310NFPA.mcf/5320NFPA.mcf containssetup information for the expansion outputs, designed to operate the 549 NFPA110annunciator module in conjunction with the P130 input expansion module.For further information on the P130 and P549 modules, please see the DSE manualentitled P130 input expansion module/P549 remote annunciator Operators Manual.DSE5xxx Configuration software ISSUE 2 02/07/04 AM 31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!