DSE 5xxx Configuration Software ManualFunctionExpansion analogue inputselectionsDescriptionEnable P130 input expansion: P130 input expansion module is not fitted. Relevant parameters areremoved from the tab. P130 input expansion module is fitted. The adjustable parametersfor input expansion will now be shown.CAUTION!: If P130 input expansion is enabled, andthe P130 input expansion module is not correctlyconnected and powered up, the 53xx controller willgenerate a ‘link lost’ alarm indicating the failure.Input Transducer name:The name of your expansion analogue input, for example “Rad watertemp”Activation:Always active -The input selected to be an indication or alarm evenwhen the module is in the STOP/RESET MODE.Active from starting -The Auxiliary input is only active once an attemptto start the generator is made. It will remain active until the generatoris at rest again.Active from safety on - Auxiliary inputs are only active once the SafetyOn timer has timed out. This allows a delay on start up for faults, suchas Oil Pressure and High Engine Temperature Warnings, or othershutdown conditions which require a delay during start-up, such asUnder-voltage.Input transducer type:Not used - The input will not be monitored.Digital Switch, Normally Closed - The input is fed from an engine mountedswitch. The switch returns a closed signal during normal conditions,should the temperature rise above the switch manufacturers trip pointthe switch contacts will open.Digital Switch, Normally Open - The input is fed from an engine mountedswitch. The switch returns a closed signal during fault conditions,should the temperature rise above the switch manufacturers trip pointthe switch contacts will close.Further options available in this list depend upon the ‘Units’ selected :Units: Pressure = The expansion analogue is configured for a pressuresender. Transducer types available are :VDO match, 0-5barVDO match, 0-10barDatcon match, 0-5barDatcon match, 0-10barMurphy, 0-7bar Temperature = The expansion analogue is configured for atemperature sender. Transducer types available are :VDO match, 120 o C*Datcon HIGH matchMurphyCummins Percentage = The expansion analogue is configured for apercentage reading sender. The sender must be ‘linear’ in terms of and the measurement level. This type of input is most suited for fluidlevel measurement. Transducer types available are :VDO Ohms type - operating range = 10(empty) to 180(full).VDO Tube type – operating range = 90(empty) to 0(full).US Ohms Range - operating range = 240(empty) to 33(full).GM Ohms Range (high) - operating range = 0(empty) to 90(full).GM Ohms Range (low) - operating range = 0(empty) to 30(full).Ford - operating range = 73(empty) to 10(full).28DSE 5xxx Configuration software ISSUE 2 02/07/04 AM

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!