11.07.2015 Views

FGM-3,FGM-6 Data sheet - Willow.co.uk

FGM-3,FGM-6 Data sheet - Willow.co.uk

FGM-3,FGM-6 Data sheet - Willow.co.uk

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Sensing element/Gauge<strong>FGM</strong>-3,<strong>FGM</strong>-6 <strong>Data</strong> <strong>sheet</strong>FeaturesApplications. Very small surface mountable package, Easy to mount on PCB . Industrial instrumentation. Vacuum pressure measurable. Pressure switch, Pneumatic device. Non-<strong>co</strong>rrosive liquid measurable(<strong>FGM</strong>C-3, <strong>FGM</strong>C-6 available) . Medical device. Turbo boost pressure measurement for Automotive systemPart number for orderingModel<strong>FGM</strong><strong>FGM</strong> C - 3 07P G S RRated pressure(PSI)Length of the pressure port3:3mmTerminal leads <strong>co</strong>nfiguration6:6mmPressure type S : Surface mount packageG : Gauge pressureAvailable pressure mediaNo mark : Non-<strong>co</strong>rrosive gas onlyC : Non-<strong>co</strong>rrosive gas and liquidTerminal leads direction(See Outline Diagram)R:Pressure type<strong>FGM</strong>-3Gauge pressure<strong>FGM</strong>-6ModelPackage <strong>co</strong>nfiguration Surface mount package, 3mm pressure port Surface mount package, 6mm pressure portMeasurable pressure range (kPa)Part number for ordering13.79 13.79 <strong>FGM</strong>-302PGSR <strong>FGM</strong>C-302PGSR <strong>FGM</strong>-602PGSR <strong>FGM</strong>C-602PGSR34.47 34.47 <strong>FGM</strong>-305PGSR <strong>FGM</strong>C-305PGSR <strong>FGM</strong>-605PGSR <strong>FGM</strong>C-605PGSR48.26 48.26 <strong>FGM</strong>-307PGSR <strong>FGM</strong>C-307PGSR <strong>FGM</strong>-607PGSR <strong>FGM</strong>C-607PGSR98.07 103.4 <strong>FGM</strong>-315PGSR <strong>FGM</strong>C-315PGSR <strong>FGM</strong>-615PGSR <strong>FGM</strong>C-615PGSR98.07 206.8 <strong>FGM</strong>-330PGSR <strong>FGM</strong>C-330PGSR <strong>FGM</strong>-630PGSR <strong>FGM</strong>C-630PGSR98.07 344.7 <strong>FGM</strong>-350PGSR <strong>FGM</strong>C-350PGSR <strong>FGM</strong>-650PGSR <strong>FGM</strong>C-650PGSR98.07 482.6 <strong>FGM</strong>-370PGSR <strong>FGM</strong>C-370PGSR <strong>FGM</strong>-670PGSR <strong>FGM</strong>C-670PGSR98.07 827.4 <strong>FGM</strong>-3120PGSR <strong>FGM</strong>C-3120PGSR <strong>FGM</strong>-6120PGSR <strong>FGM</strong>C-6120PGSRModel/Rated pressure 02PG 05PG 07PG 15PG 30PG 50PG 70PG 120PG UnitRe<strong>co</strong>mmended operating <strong>co</strong>nditionsPressure typeGauge pressureRated pressure13.79 34.47 48.26 103.4 206.8 344.7 482.6 827.4 kPa0.141 0.352 0.492 1.055 2.109 3.516 4.922 8.437 kg/cm 2Measurable pressure range13.79 34.47 48.26 98.07 98.07 98.07 98.07 98.0713.79 34.47 48.26 103.4 206.8 344.7 482.6 827.4kPaPressure media<strong>FGM</strong> : Non-<strong>co</strong>rrosive gas only, <strong>FGM</strong>C : Non-<strong>co</strong>rrosive gas and liquidExcitation current (Constant) 1.5 mADCAbsolute maximum ratingMaximum load pressure Twice of rated pressure 1.5times of rated pressureMaximum excitation current 3 mADCOperating temperature 20 100Storage temperature 40 120Operating humidity 30 80 (No dew <strong>co</strong>ndensation) RHElectric performances/characteristics (Excitation current I=1.5mA <strong>co</strong>nstant, Ambient temperature Ta=25 )Full scale span voltage 60 140 mVOffset voltage 20 mVBridge impedance 4000 6000Mechanical response time 2 (For the reference) msecTemperature sensitivity of offset (TSO) 5 FS/0 50Temperature <strong>co</strong>efficient of sensitivity (TCS) 2.5 FS/0 50Linearity 0.5 0.3 0.5 0.6 FSPressure hystersis 0.4 0.2 0.4 FS) Please <strong>co</strong>nsult us available liquid pressure media when you chose the C models.AccuracySpecifications1


1Sensing element/Gauge<strong>FGM</strong>-3,<strong>FGM</strong>-6 <strong>Data</strong> <strong>sheet</strong>Outline dimensions<strong>FGM</strong>-3Pressure port2.54 2.541 2 30.8unit(mm)76 5 47Vent holeIndex30.153.5 36.50.810.315 MAX.6 5 40.25Labelled faceplateRe<strong>co</strong>mmended footprint for PCB1.71.42.542.541 2 3Land-pads9.4unit(mm)<strong>FGM</strong>-6Pressure port2.54 2.540.81 2 3unit(mm)76 5 473Vent holeIndex0.810.315MAX.Projections6 5 42-R0.50.250.5 3.5 69.5Re<strong>co</strong>mmended footprint for PCB11.72- 1(Holes for projections)1.42.546.22.54Projections1 2 3Labelled faceplateLand-pads6.29.4unit(mm)2


Sensing element/Gauge<strong>FGM</strong>-3,<strong>FGM</strong>-6 <strong>Data</strong> <strong>sheet</strong>Connection diagram<strong>FGM</strong>i1.5mAunit(mm)2Output voltageConstantcurrentsource3R2R116R3R451VR06Zero balancing trimmer (VR0) is available.VR0:200Note ; Please read instruction “Notes” before using the sensor.Fujikura reserves the right to change specifications without notice.If you have any questions regarding technical issues or specifications, please <strong>co</strong>ntact us.Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, JapanPhone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-15383E-mail : sensor@fujikura.<strong>co</strong>.jp

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!