11.07.2015 Views

English Low Resolution - abi data Website

English Low Resolution - abi data Website

English Low Resolution - abi data Website

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

forall recordingneeds


GeneralThe µLog <strong>data</strong> logger familyis the result of the years ofexperience acquired bya.b.i. <strong>data</strong> in the <strong>data</strong>logger field. The mainfeatures aimed at in thisdevelopment areminiaturisation, reli<strong>abi</strong>lity,user friendliness and valuefor money.The range covers specialisedloggers (CL200, PL300and TL500) and loggers forgeneral use (VL100,DL400C, DL400E and FL600).Specialised loggers arerecommended for electricitydistribution –recordingcurrents in cables andtransformers – for waterdistribution – pressure andflow recording in pipes –and for air conditioning,food industry and storage.Loggers for general userecord physical parameterssuch as temperatures,pressures, flow rates,levels, concentrations,potentials, etc… withtransducers deliveringanalog signals(0-1V,4-20mA, etc…) or digitalsignals (logic states orcounting pulses).SoftwareThe WINDOWS softwareis powerful, user friendlyand specific for each typeof <strong>data</strong> logger.The configuration moduleis used to set therecording parameters andto scale the inputs.The processing moduleretrieves the off-loaded <strong>data</strong>from the logger in order toproduce the requestedreports (graphics, statistics,ASCII files for importing intoEXCEL software, …).Real time display of thereadings is also provided.General Features• easy to connectand to run.• up to 2 years battery lifein intensive use –battery easy to replace.• non-volatile memory of15,000 or 60,000 samples.• WINDOWS software forlaunch configurationand retrieval of recorded<strong>data</strong>.• off-loading of recorded<strong>data</strong> even when stillrecording.• battery voltagemonitoring.• remote operationvia modem.• from 1 sec up to60 minutes (or 12 hours)recording interval.• 0.5% resolution,1% precision.• -20°C to +65°C operationtemperature range.• starting recording: onprogrammed date andtime or without delay.• stop on memory full oroverwrite oldest records(FIFO).• real time clock.• security: automatic stopon low battery;non-volatile memory.• communication: RS232interface, DSub9Fconnector.2


Typical applicationsIn small waste watertreatment plants, VL100 isused for recording dissolvedoxygen concentration, flow rateand other parametersinfluencing the process.0-20mA and 0-1V signalscoming from the controlequipment are used for recording.Recordings allow for periodicmonitoring of all plantsand for checking the treatment.Electricity power distributioncompanies use CL203recorders and a set of currentclamps for monitoring currentoverloads in three phase lowvoltage distribution cables.Recordings are running for oneweek and a same recorder willmonitor a number of cablesduring the winter peak period.A set of recordings allows forreasoned decisions whenconnecting extra users on to acable, adding new distributioncables or scheduling newtransformers.Water distribution companiesuse PL301 in order toprovide the correct pressureall over the network. PL302C,connected to water meterswith pulse output in differentcritical points of a distributionnetwork or at important usersallows for checking whetherthe network structure cancope with peak flow rateswhen they occur.Fighting severe competition,marketing departments ofpower companies useDL400C as a powerfuladvantage in providing serviceto customers. Loggers areconnected directly to metersequipped with pulse outputsfor active and reactive power.A month’s recording provides<strong>data</strong> for customer poweroptimisation proposals.TL500 with its <strong>abi</strong>lity toconnect up to 8 temperaturesensors, helps to optimise airconditioning or heating inoffices or to check the refrigerationin stores or in smallsupermarkets. A temporarytwo or three day recording willdo to optimise settings or for aperiodic check. A permanentset up may be necessary forregulatory compliance or forquality assurance.General applicationsApplication fields:Power distribution: . . . . . . . . . . . . .CL203 - DL400CWater distribution: . . . . . . .PL302 - DL400C - FL600Gas distribution : . . . . . . . . . . . . . . . . . . . . .DL400CWaste water treatment: . . . . . . . . . . . . . . . . .VL100Air conditioning: . . . . . . . . . . . . . . .DL400E - TL500Environment: . . . .VL100 - DL400C - TL500 - FL600Air compressors:VL100 - PL301 - DL400C - DL400EManufacturing industry: . . . . . . . .VL100 - DL400CFrozen and chilled products storage: . . . . .TL500Recording of:Voltage, current: . . . . . . . . . . . . . . . .VL100 - CL203Counting pulses: . . . . . . .DL400C - FL600 - DL400ETemperature: . . . . . . . . . . . . .TL500 - VL100 - FL600Pressure: . . . . . . . . . . . . . . . . . . . . . .PL301 - VL100Flow: . . . . . . . . . . .VL100 - PL302 - DL400C - FL600Manufacturing rate: . . . . . . . . . . . . . . . . . . .DL400CEvents: . . . . . . . . . . . . . . . . . . . . . .DL400E - VL100Rainfall: . . . . . . . . . . . .FL600 - DL400C - DL400ELevel: . . . . . . . . . . . . . . . . .VL100 - PL301 - FL6003


Miniature recorder with 8 analog inputs• 8 analog DC voltage or current inputs.• High impedance inputs ; over voltageprotection.• Long battery life – easy to replace.• Miniature.• Processing in engineering units, each channelindividually.• Real time measurements output and modemconnectivity provided.ApplicationsWaste water treatment monitoring.Environmental measurements.Quality control.Process monitoring.Physiological applications.Maintenance.VL100 recorders are alsoproposed as OEM productswith or without housing, forintegration into medicalequipment, gas analysers,production control devices,etc… May also be adapted fornetworking (RS485). DLL componentsare proposed to helpintegrate µLog <strong>data</strong> intocustomer’s software.VL100 recorders and accessoriesFull VL100 technicalspecifications are available atwww.<strong>abi</strong><strong>data</strong>.be or by request.VL100: eight 0-1V DC common point inputs,eight 4-20 mA inputs, withCI8x20mA cable.VL100S: eight 0-100mV to 0-30V commonpoint inputs, on request.CI8x20mA: connection cable for eight 4-20 mAcommon point inputs (mixed 0-1Vand 4-20 mA inputs on request).CI8xV: straight connection cablefor 8 inputs.µLOGVL: VL100 WINDOWS software.-EXT: memory extension, x 4.D9-2FM: PC connection cable.RDFIX: DIN rail fixation adapter.AC current recorder for clamp probesand current transformers• Three or single phase recorders.• Suitable for most common AC currentclamps or CT.• Types for signals of 5A, 1A or 1V AC(others by request).• Long battery life – easy to replace.• Miniature.• Easy to connect and to run.• Recorded <strong>data</strong> processed in primary currents.• Real time measurements output and modemconnectivity provided.4


Applications(Over)load recording in cables and transformers.Suitable for small post-mounted c<strong>abi</strong>netsin aerial power distribution.Power management (quarter hour peaks penalties).Monitoring periodic current evolutionduring long run.Phase balance monitoring.CL200 recorders and accessories.M1 clamps: 10 to 200ACL203-1A:3 current inputs 1A AC.µLOGCL:CL200 WINDOWS software.CL203-5A:3 current inputs 5A AC.-EXT:memory extension, x 4 (for CL201).CL203-1V: 3 voltage inputs 1V AC(others by request).CL201-xA: 1 current input 1 or 5A .D9-2FM:RDFIX:PC connection cable.DIN rail fixation adapter.S, US clamps: 250 to 1000AFull CL200 technical specifications are availableat www.<strong>abi</strong><strong>data</strong>.be or by request.Pressure and flow recorder• Built-in 0-10 bar pressure sensor (other rangesby request) flow rate measurement by pulsecounting or analog signal.• Easy connection to water, air orhydraulic circuits.• Long battery life – easy to replace.• Miniature, IP66 enclosure.• Processing of each channel inengineering units.• Real time measurements output and modemconnectivity provided.ApplicationsWater distribution network supervision.Compressed air or hydraulic circuit maintenance.Water level monitoring.Leak detection.Full PL300 technical specificationsare available atwww.<strong>abi</strong><strong>data</strong>.be or by request.PL301:PL302C:PL300 recorders and accessories1 pressure input 0-10 bar.1 input 0-10 bar + 1 flow inputby pulse counting.PL302A: 1 input 0-10 bar + 1 analog inputsignal 4-20mA or 0-1V.PL30xXS: 0.5 to 250 bar pressures (by request).µLOGPL: PL300 WINDOWS software.-EXT: memory extension, x4.D9-2FM: PC connection cable.5


Digital recorder with 8 counting inputs• 8 digital inputs, voltage or dry contact.• 8 bit (0-255) or 16 bit (0-65535) counters,selectable.• Long battery life – easy to replace.• Miniature.• Processing in engineering units, eachchannel individually.• Real time measurements output andmodem connectivity provided.ApplicationsElectricity, water and gas distribution.Power management and load profiles.Production monitoring. Dosage recording.Traffic statistics. Access counting.DL400C recorders are alsoproposed as OEM productswith or without housing, forintegration into equipment.May also be adapted fornetworking (RS485).DLL components are proposedto help integrate µLog <strong>data</strong> intocustomer’s software.DL400C recorders and accessoriesFull DL400C technical specificationsare available atwww.<strong>abi</strong><strong>data</strong>.be or by request.DL400C: eight 8/16 bit counting inputs.µLOGDLC: DL400C WINDOWS software.-EXT: memory extension, x4.CI8xV:D9-2FM:RDFIX:straight connection cablefor 8 inputs.PC connection cable.DIN rail fixation adapter.• 8 digital inputs, voltage or dry contact.• Detects events = digital input state changes.• Detects on/off or off/on transitions or both.Digital recorder with8 event inputs• Long battery life – easy to replace.• Miniature.• Real time measurements output; modemconnectivity provided.• Special pre-treated Excel files are provided.• Same presentation as DL400C.ApplicationsFull DL400E technical specificationsare available atwww.<strong>abi</strong><strong>data</strong>.be or by request.Recording of sporadic or momentarycontact closures (relay, switch,…)Rainfall.Run time and on/off cycling recording of fans,compressors, air conditioning, pumps, heating,…Access survey.DL400E recorders and accessories6DL400E: 8 event inputs, 2.000 events memory.µLOGDLE: DL400E WINDOWS software.-EXT: memory extension, x4.CI8xV:D9-2FM:RDFIX:straight connection cable for8 inputs.PC connection cable.DIN rail fixation adapter.


Temperature recorder with 8 channels• Connects up to 8 digital temperature sensorsin network.• Two-wire network up to 300 meter long.• High 16 bit resolution – range selectablefrom –50 to +125°C.• Min/max alarm settings per channel.• Long battery life – easy to replace.• Miniature yet powerful.• Real time measurements output and modemconnectivity provided.• Works also as a stand alone single channeltemperature logger.• Temporary logging or permanent set up.TL500 networkTemporary set upTS1Permanent set upTS1TS1TL500TS1RS232max.length 4m1mD9-2FMcable1.8mTL500TL-FLCcable5mTS2TS22-wirenetworkmax. 300mTS1 TS1RS232 max.length 20maux. supply6-30V DC100mAD9-2FMcable 1.8m1,5mTL-INTTS22-wire networkmax. 300mTS2TS1 TS1TL500 is easy to install and torun. The temperature sensorsare interconnected by a twowire category-5 cable (similar toa telephone twisted pair) andare automatically recognised bythe logger. No converters areneeded. TL500 configuration iseasy and similar to a singlechannel temperature logger.ApplicationsBuilding temperature/air conditioning survey;energy management.Frozen and chilled food temperature follow up inshops and (small) supermarkets.Temperature survey in compartmentalisedrefrigerated stores.Environmental monitoring in horticulture,breeding and agriculture.Multipoint temperature distribution monitoring inreactors, processing tunnels, soil, conditionedrooms, green houses, buses,train compartments, etc…Full TL500 technical specificationsare available atwww.<strong>abi</strong><strong>data</strong>.be or by request.TL500:TL500 recorders and accessories8 channel temperature recorder, onebuilt-in temperature sensor.sensors network and auxiliarypower supply).µLOGTL: TL500 WINDOWS software.-EXT: memory extension, x 4.TL-FLC: PC connection cable, networkdeparture.TL-INT: interface box for permanent set up:alarm signalling (audible and relay) andconnections (RS232, temperatureTS1:TS2:D9-2FM:RDFIX:watertight stainless steel temperatureprobe, 3m cable.ambient temperature sensor;fixation hole.2m adaptor cable for easy PCconnection.DIN rail fixation adapter.Flow recorderThree channels : counting pulses, voltage andtemperature. For recording flow, rainfall, loadcharacteristics,….Full specifications are available atwww.<strong>abi</strong><strong>data</strong>.be or by request.7


Miniature recorder with 8 analog inputs.VL100VL100SµLOGVLeight 0-1V DC common point inputs,eight 4-20 mA inputs, with CI8x20mAcable.eight 0-100mV to 0-30V common pointinputs, on request.WINDOWS software.• Waste water treatment monitoring.• Environmental measurements.• Process monitoring.• Quality control.• Physiological applications.AC current recorder for clamp probes and current transformers.CL203-1A 3 current inputs 1A AC.CL203-5A 3 current inputs 5A AC.CL203-1V 3 voltage inputs 1V AC (others by request).CL201-xA 1 current input 1 or 5A.µLOGCL WINDOWS software.• Power distribution: (over)load recording incables and transformers; periodic currentevolution.• Power management (peaks).• Phase balance monitoring.Pressure and flow recorder with built in pressure sensor.PL301 1 pressure input 0-10 bar(other by request).PL302C 1 input 0-10 bar + 1 flow inputby pulse counting.PL302A 1 input 0-10 bar + 1 analog inputsignal 4-20mA or 0-1V.µLOGPL WINDOWS software.• Water distribution networks.• Leak detection.• Compressed air or hydraulic circuitmaintenance.• Water level monitoring.Eight inputs digital recorder.DL400C with 8 counting inputs.DL400C eight 8/16 bit counting inputs.µLOGDLC WINDOWS software.DL400E with 8 event inputs.DL400E eight event inputs.µLOGDLE WINDOWS software.• Electricity, gas and water distribution.• Production monitoring.• Monitoring contact position (relays).• Checking processing cycles.Temperature recorder with 8 channels.TL500µLOGTLTL-INTTS1TS28 channel temperature recorder,one built-in sensor.WINDOWS software.interface box for permanent set up.watertight temperature probe.ambient temperature sensor.• Building temperature survey.• Food shops and (small) supermarkets.• Compartmentalised refrigerated stores.• Multipoint temperature distribution in reactors,tunnels, green houses, etc…FL600µLOGFLFlow logger.3 channels; counting pulses, voltageand temperature.WINDOWS software.• Flow (+ level or pressure).• Rainfall. Temperatures.• Load characteristics.Options and accessories common to all types:-EXT memory extension, x 4.D9-2FM µLog to PC connection cable.RDFIX DIN rail fixation adapter.µLog recorders are also proposed asOEM products with or without housing,for integration into medical equipment,gas analysers, production controldevices, etc… May also be adapted fornetworking (RS485 or modem). DLLcomponents are proposed to helpintegration of µLog <strong>data</strong> into customer’ssoftware.Full technical specifications of each individual µLog are available at www.<strong>abi</strong><strong>data</strong>.be or by request.Data logger . Data acquisition . Data communications .Ch. de Vleurgat 282, 1050 Bruxelles, Belgique. • Tel: +32-(0)2-647.82.00 •Fax: +32-(0)2-646.14.11 • E-mail: mail@<strong>abi</strong><strong>data</strong>.be

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!