Rotating Electrical MachinesW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong><strong>motors</strong>Frames 80 - 355L2204E


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>W <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>80 - 355L<strong>Brook</strong> <strong>Crompton</strong><strong>Brook</strong> <strong>Crompton</strong> is a leading manufacturer ofelectric <strong>motors</strong> for the global industrialmarket, with motor solutions which benefit awide range of customers.Our products are used in almost everyindustrial activity including water treatment,building services, chemical/petrochemicals,general processing and manufacturing wherethey drive fans, pumps, compressors andconveyors, amongst other things.<strong>Brook</strong> <strong>Crompton</strong> incorporates many wellknown names including <strong>Brook</strong> Motors,<strong>Crompton</strong> Parkinson, Electrodrives,Newman, Bull Electric and Hawker SiddeleyElectric Motors.We have extensive stocks of <strong>motors</strong> aroundthe world, backed-up by a network ofdistributors, ensuring excellent local supportwherever needed.Quality assuranceStringent quality procedures are observedfrom first design to finished product inaccordance with the ISO9001 documentedquality systems.All of our factories have been assessed tomeet these requirements, a furtherassurance that only the highest possiblestandards of quality are accepted.W <strong>EEx</strong> <strong>nA</strong> <strong>motors</strong><strong>Brook</strong> <strong>Crompton</strong> has one of the widestavailable ranges of electric <strong>motors</strong> foroperation in hazardous atmospheres andhostile environments.We have over 90 years’ technical and designexperience in this most specialised marketand are able to ensure the correct selectionof <strong>motors</strong> for any application, taking into fullaccount the two most important factors to beconsidered - safety and economy.The W <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> motor rangecovers products with outputs from as little as0.18kW to 400kW in frame sizes 80 to 355L.Motors are manufactured in factories that arelicensed by a European notified body (egEECS/BASEEFA, PTB), meeting rigorousquality controls.Benefits include:• high efficiency for low running costs• high reliability for long life• low noise levels• cool running for long insulation life• Eurovoltage: 400V ±10%• dual frequency: 50Hz and 60Hz• high power factors• high torque with smooth acceleration andlow current• 2-year warranty• IP55 protection• 4-position cable entryEfficiency<strong>Brook</strong> <strong>Crompton</strong> are an approvedmanufacturer of ac electric <strong>motors</strong> within theUK Government’s Enhanced CapitalAllowance (ECA) scheme. A wide range ofsingle and multi-speed <strong>motors</strong> are includedon the UK Energy Technology List. Pleasecheck the ECA scheme website:www.eca.gov.uk at time of purchase forcurrent listing.ATEX<strong>Brook</strong> <strong>Crompton</strong>’s range of <strong>EEx</strong> <strong>nA</strong> <strong>motors</strong>are fully compliant with the requirements ofATEX Directive (94/9/EC).2


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Standards and environmentStandardsStandardsNational standardRange UK EuropeanInternationalNorth AmericanStandardBSBSVDEDINNFIECNEMA*OutputsBS 5000 part 10,appendix ABS 5000 part 10–DIN 42673, DIN 42677NF C51-110–MG1 part 10PerformanceBS 4999 Part 101BS 4999 part 101VDE 0530 part 1–NF C51-111IEC 60034-1MG1 part 12DimensionsBS 4999 part 141 as DIN and NF–DIN 42673, DIN 42677NF C51-105, NF C51-120IEC 60072-1MG1 part 4MountingEN 60034-7EN 60034-7–DIN 42950NF C51-117IEC 60034-7MG1 part 4Degrees of IP protectionEN 60034-5EN 60034-5–DIN 40050NF C51-115IEC 60034-5MG1-1.26B<strong>EEx</strong> <strong>nA</strong>Non-<strong>sparking</strong>EN 50014EN 50021EN 50014EN 50021--–IEC 60079-15–standard motor compliesoptionalMotors complying with IEC 60034-1 also comply with many of the national standards of other European countries, eg CEI 203 (Italy), NBN7 (Belgium), NEN 3173 (Netherlands),SEN 2601 01 (Sweden) *Motors to NEMA standards have CSA approval and generally comply with Canadian (EEMAC) standards.EnvironmentEnclosureAll <strong>motors</strong> have degrees of IP protectionas defined in IEC EN 60034-5.European directivesFour European directives apply invarying degrees to ac induction <strong>motors</strong>.<strong>Brook</strong> <strong>Crompton</strong> comply in the followingmanner:Motor coolingMotors are cooled in accordance withEN 60034-6. The normal arrangementis IC411 (Totally Enclosed Fan Ventilated) viaa fan mounted at the <strong>non</strong>-drive end.Alternative methods of cooling available onrequest.Compliance with European directives applying to AC induction <strong>motors</strong>DirectivesLow voltage(LV)Machinery(MD)Electromagnetic compatibility(EMC)ATEXReference numbers73/23/EEC93/68/EEC89/392/EEC91/368/EEC89/336/EEC92/31/EEC94/9/EC93/44/EEC93/68/EEC93/68/EECMotor CE markedStandardsDocumentation for customers’ technical fileSafety instructions with every motorCommentYesEN 60034Declaration of conformityYesRelevant electricalequipment operatingbetween50 to 1000 volts ACNoNot applicableCertificate of incorporationYesStatement (2)NoEN 60034-1Statement (1)YesComponentYESEN 50014EN 50021Declaration of conformityYesHazardous atmosphereequipment - mandatoryafter July 2003(1) Motors operating from a correctly applied, sinusoidal (AC) supply meet the requirements of the EMC directive and are within the limits specified in standardEN 60034-1(2)When installed in accordance with our customer safety and installation and maintenance instructions, they can be put into service only when the machinery intowhich they are being incorporated, has been declared to be in conformity with the machinery directive in accordance with Article 4(2) and Annex IIB of that Directive(98/37/EEC)3


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong><strong>EEx</strong> <strong>nA</strong> and <strong>EEx</strong> <strong>nA</strong> EEMUA specificationN<strong>EEx</strong> <strong>nA</strong> (<strong>non</strong>-<strong>sparking</strong>) <strong>motors</strong>Frame Sizes W-DF80 to W-DF355Suitable for use in Group II Zone 2 locations.GeneralThe construction of <strong>EEx</strong> <strong>nA</strong> <strong>motors</strong> is similarto standard TEFV <strong>motors</strong>, but with specialattention to eliminate production of arcs,sparks or dangerous surface temperatures.Air gap concentricity is rigidly inspectedthroughout manufacture, and the structure ofthe motor is impact-tested. All <strong>motors</strong> complywith the requirements of the ATEX Directive(94/9/EC).Temperature classAn important feature of the motor design isthe limitation imposed on the external orinternal surface temperature that can beattained under all conditions except starting.This range of <strong>motors</strong> is suitable for use ingases with auto ignition temperature notlower than T3, ie 200°C. For temperatureclasses T4, T5 and T6 - please consult <strong>Brook</strong><strong>Crompton</strong>.Terminal boxStandard and alternative terminal boxpositions are available as detailed in the tablebelow (positions detailed are looking on driveend of motor).CertificationThe <strong>motors</strong> are certified by a Europeannotified body who also grant the licence tomanufactureCertificate NumbersFrame sizeCertificate NoW-DF80 to W-DF180 BAS00ATEX3119XW-DF200 to W-DF355L BAS00ATEX3133X<strong>EEx</strong> <strong>nA</strong> motor certification plateDual zonesSome installations may be subjected to morethan one type of hazard. The presence ofgases and vapours etc may occur withcombustible dusts. Under thesecircumstances, it is possible to supply <strong>motors</strong>with certification for both hazards. Furtherdetails are available from <strong>Brook</strong> <strong>Crompton</strong>.<strong>EEx</strong> <strong>nA</strong> heater ratings<strong>EEx</strong> <strong>nA</strong> EEMUA (<strong>non</strong>-<strong>sparking</strong>)<strong>motors</strong>Frame sizes W-DF80 to W-DF355Suitable for use in Group II Zone 2 locations.GeneralThe <strong>Brook</strong> <strong>Crompton</strong> <strong>EEx</strong> <strong>nA</strong> EEMUA motorrange covers products from 0.18kW to280kW.StandardsAll <strong>motors</strong> comply with the requirements ofEEMUA (The Engineering Equipment andMaterials Users Association) Pub no 132-1988and with leading petro-chemical industryspecifications. They are manufactured inaccordance with EN 50021 and are certifiedfor use in Zone 2, hazardous areas.PerformanceIn accordance with BS 5000 Part 99 andIEC60034-1. Motors up to and including 40kWrated output have a starting characteristic inaccordance with BS 4999 Part 112, design N.Motors above 40kW rated output have acharacteristic in accordance with design D.Full performance data is available on request.Temperature classMaximum surface temperatures are limited toT3.Terminal box positions availableFrame size Top LHSW-DF80-90 - AlternativeW-DF100-180 Alternative AlternativeW-DF200-355 Standard AlternativeImpact coversRHSStandardStandardAlternativeDesigned to prevent the ingress of fallingforeign bodies, impact covers are fitted on<strong>motors</strong> when mounted verticaly, shaft down.Vertically mounted <strong>motors</strong> fitted with impact coverIncreaseEuropean frame BS frame in L DimFrame size8090100112132160180200225250280315355Heater rating240V110V121212121212141424244040404029294842484296849684192169Mechanical featuresFerrous cooling fansSheet steel fan coversCollar type eyeboltsCast iron stator frames and endshieldsReduced balanceIP55 enclosureSpecially stamped nameplateThrough greasing frames 160 and abovePhase barriers, for use with either shellclamps or uninsulated cable lugs, arestandard on <strong>motors</strong> to EEMUA. By fitting alarger terminal box, solid aluminium cablescan be catered for.W-DF80M-90LW-DF100L-112MW-DF132S-180LW-UDF200LXW-UDF225S/MW-UDF250MEW-UDF280SEW-UDF280MEW-UDF315SEW-UDF315MEW-UDF315M/LW-UDF355S/M/LW-DF80M-90LW-DF100L-112MW-DF132S-180LW-DF200LXW-DF225S/MW-DF250SW-DF250MW-DF280SW-DF280MW-DF315SW-DF315M/LW-DF355S/M/L293040454545484848485365Terminal pin cable capacity and terminal nut tightening torqueCable capacity (mm 2 )Frame size T box size Mains terminals Aux terminals80-100112-13280-100112-1324 (M4)10 (M5)44112-132160-18010 (M5)16 (M6)44160-180200L-280S280M-355L160-180200-280S280M-355L16 (M6)95 (M10)300 (M10)42.52.5Tightening torque (Nm)Mains terminals1.533552626Aux terminals0.5-0.80.5-0.80.5-0.80.5-0.80.5-0.8114


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Mounting optionsApproximate shipping specificationsTypeEuropeanBSW-DF80M W-DF80MW-DF90S W-DF90SW-DF90L W-DF90LW-DF100L W-DF100LW-DF112M W-DF112MW-DF132S W-DF132SW-DF132M W-DF132MW-DF160M W-DF160MW-DF160L W-DF160LW-DF180M W-DF180MW-DF180L W-DF180LW-UDF200LX W-DF200LXW-UDF225S W-DF225SW-UDF225M W-DF225MW-UDF250ME W-DF250SW-UDF280SE W-DF250MW-UDF280ME W-DF280SW-UDF315SE W-DF280MW-UDF315ME W-DF315SW-UDF315M W-DF315MW-UDF315L W-DF315LW-UDF355S W-DF355SW-UDF355M W-DF355MW-UDF355L W-DF355LNet weight (kg) Gross weight (kg) Cubage (m 3 )15192235.5456872.5121133162177.525532037542057066080010001100130020002300250016.520.523.538487178.5133145178193.52703353904606107218711095119513952120242026200.020.030.030.030.050.080.080.150.150.210.210.300.370.370.630.701.21.21.81.81.82.32.32.35


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Performance data3000 min –1 (2 pole)Rated powerFull load speed inrevolutions per minuteFrame referenceand sizeFull load current atrated voltageEfficiencyPower factorFull load torqueDirect on linestarting torque ratioDirect on linestarting current ratioDirect on linepull out torque ratioDirect on linepull up torqueStar deltastarting torque ratio (1)Star deltastarting current ratioStar deltapull up torqueRotor inertia WK 2Mean sound pressure level@ 1m on no loadP NkW(hp)0.75(1)1.1(1.5)1.5(2)2.2(3)3(4)4(5.5)5.5(7.57.5(10)11(15)15(20)18.5(2522(30)30(40)37(50)45(60)55(75)nmin –12850287528502860288028702910290029352935294029502940294029552955Type380 VAI N400 VA415 VAη1.0 P N0.75 P N0.5 P NCos Ø1.0 P N0.75 P N0.5 P NM NNm{ }0.001477.0 0.83W-DF80ME (1)1.77 1.69 1.69 77.0 0.77 2.5 2.2 5.5 2.5– – –73.0 0.6581.0 0.82W-DF80MJ (1)2.51 2.39 2.39 3.7 2.7 6.7 2.7 2.4 – – – 0.0019{ }78.0 0.6382.0 0.82W-DF90SF (1)3.4 3.2 3.2 5.0 2.5 6.0 3.0 2.2 – – – 0.0023{ }81.0 0.6384.0 0.86W-DF90LM (1)4.6 4.4 4.4 7.4 2.5 6.3 3.0 2.2 – – – 0.0028{ }83.0 0.7186.5 0.88W-DF100LJ (1)5.9 5.7 5.7 10.0 3.0 7.8 3.1 2.6 – – – 0.006{ }86.5 0.7588.0 0.91W-DF112MM (1) 7.6 7.2 7.2 13.3 3.0 7.8 3.1 2.8 0.85 2.8 0.80 0.008{ }89.0 0.8589.5 0.89W-DF132SE (1)10.5 10.0 10.0 18.1 2.7 8.2 3.1 2.4 0.80 2.4 0.75 0.017{ }88.0 0.7389.5 0.91W-DF132SJ (1)14.0 13.3 13.3 24.7 2.5 8.2 3.0 2.3 0.75 2.5 0.70 0.02{ }89.0 0.8290.5 0.89W-DF160MB (1) 20.7 19.7 19.7 35.8 2.2 7.8 3.0 1.8 0.65 2.5 0.60 0.039{ }89.7 0.7991.3 0.90W-DF160MJ (1)27.7 26.3 26.3 48.8 2.2 8.0 3.1 1.9 0.65 2.6 0.60 0.045{ }91.2 0.8091.8 0.91W-DF160LR (1)34 32 32 60.2 2.4 8.7 3.2 1.9 0.78 2.7 0.65 0.056{ }91.3 0.8192.2 0.92W-DF180ME (1)39 37 37 71.4 2.2 9.0 3.1 1.9 0.65 2.8 0.60 0.094{ }91.0 0.8492.9 0.89W-UDF200LGX (2)55 52 510.15W-DF200LGX 97 2.7 7.8 2.9 2.3 0.75 2.5 0.60{ }(3)92.0 0.8093.3 0.89W-UDF200LNX (2)67 64 620.18W-DF200LNX 120 2.7 7.8 2.9 2.3 0.75 2.5 0.60{ }(3)92.5 0.8093.7 0.90W-UDF225MN (2)81 77 740.47W-DF225MN 145 2.3 7.8 2.8 1.9 0.65 2.5 0.50{ }(3)92.5 0.8394.0 0.90W-UDF250MNE (2)99 94 900.56W-DF250SN 178 2.3 7.8 2.8 1.9 0.65 2.5 0.50{ }(3)93.0 0.83M AM NI AI NM KM SM NM N2.0M AM NYI AI NYM SM NYJkgm 2L PAdB(A)64646464606066666868686873737575(1) European and BS frame reference(2) European frame reference(3) BS frame reference6For performance curves and notes - see page 23


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Performance data3000 min –1 (2 pole)Rated powerFull load speed inrevolutions per minuteFrame referenceand sizeFull load current atrated voltageEfficiencyPower factorFull load torqueDirect on linestarting torque ratioDirect on linestarting current ratioDirect on linepull out torque ratioDirect on linepull up torqueStar deltastarting torque ratio (1)Star deltastarting current ratioStar deltapull up torqueRotor inertia WK 2Mean sound pressure level@ 1m on no loadP NkW(hp).75(100)90(125)110(150)132(175)150(200)160(215)185(250)200(270)225(300)250(335)280(375)315(420)355(475)400(535)nmin –129602960297829782980298029802978298229822982298229822985TypeW-UDF280SNE (2)W-DF250MN (3)W-UDF280MNE (2)W-DF280SN (3)W-UDF315SNE (2)W-DF280MN (3)W-UDF315MNE (2)W-DF315SN (3)W-UDF315MN (2)W-DF315MN (3)W-UDF315MP (2)W-DF315MP (3)W-UDF315LN (2)W-DF315LN (3)W-UDF315LN (2)W-DF315LN (3)W-UDF355SG (2)W-DF355SG (3)W-UDF355SJ (2)W-DF355SJ (3)W-UDF355SN (1)W-DF315SN (3)W-UDF355MJ (2)W-DF355MJ (3)W-UDF355MN (2)W-DF355MN (3)W-UDF355LN (2)W-DF355LN (3)380 VA134160194233260277320346398445496551621691I N400 VA127152184221247264304329379421471524590657415 VA123146177213238254294317364405454505569633η1.0 P N0.75 P N0.5 P NCos Ø1.0 P N0.75 P N0.5 P NM NNm94.6 0.9094.9 0.88 24293.4 0.8395.0 0.9095.0 0.88 29093.5 0.8395.8 0.9095.4 0.88 35394.0 0.8395.8 0.9095.4 0.88 42394.0 0.8396.2 0.9195.8 0.89 48194.3 0.8596.3 0.9195.9 0.89 51394.4 0.8596.4 0.9196.2 0.89 59394.8 0.8596.4 0.9196.2 0.89 64194.8 0.8596.4 0.8995.9 0.87 72194.6 0.8596.4 0.8996.0 0.87 80194.8 0.8596.4 0.8996.1 0.87 89794.9 0.8596.5 0.9096.2 0.89 100995.2 0.8696.5 0.9096.3 0.89 113795.4 0.8696.6 0.9196.4 0.90 128095.6 0.87{ }{ }{ }{ }{ }{ }{ }{ }{ }{ }{ }{ }{ }{ }M AM N2.22.22.22.22.02.02.01.852.02.02.02.02.02.0I AI N7.87.87.87.87.87.87.87.27.57.57.57.57.57.5M KM SM NM N2.03.03.02.92.92.752.752.752.52.72.72.72.72.72.72.01.81.81.71.71.71.61.61.61.61.61.61.6M AM NY0.650.650.650.650.600.600.600.550.650.650.650.650.650.65I AI NY2.52.52.52.52.52.52.52.32.32.32.32.32.32.3M SM NY0.500.500.450.450.450.450.450.420.450.450.450.450.450.45Jkgm 20.70.81.41.72.42.62.82.85.05.35.96.37.08.0L PAdB(A)7777787880808080808080808080(1) European and BS frame reference(2) European frame reference(3) BS frame referenceFor performance curves and notes - see page 23 7


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Performance data1500 min –1 (4 pole)Rated powerFull load speed inrevolutions per minuteFrame referenceand sizeFull load current atrated voltageEfficiencyPower factorFull load torqueDirect on linestarting torque ratioDirect on linestarting current ratioDirect on linepull out torque ratioDirect on linepull up torqueStar deltastarting torque ratio (1)Star deltastarting current ratioStar deltapull up torqueRotor inertia WK 2Mean sound pressure level@ 1m on no loadP NkW(hp)0.55(0.75)0.75(1)1.1(1.5)1.5(2)2.2(3)3(4)4(5.5)5.5(7.5)7.5(10)11(15)15(20)18.5(25)22(30)30(40)37(50)45(60)55(75)nmin –114101410143514351440144514451450146014701470147014701470147014751475TypeW-DF80ME (1)W-DF80MG (1)W-DF90SE (1)W-DF90LK (1)W-DF100LJ (1)W-DF100LR (1)W-DF112MS (1)W-DF132SJ (1)W-DF132MR (1)W-DF160MJ (1)W-DF160LR (1)W-DF180ME (1)W-DF180LJ (1)W-UDF200LNX (2)W-DF200LNX (3)W-UDF225SN (2)W-DF225SN (3)W-UDF225MN (2)W-DF225MN (3)W-UDF250MNE (2)W-DF250SN (3)380 VA1.661.972.763.75.06.78.711.615.42229.53643577084103I N400 VA1.581.882.633.54.86.48.311.014.72128.1344154668098415 VA1.581.882.633.54.86.48.311.014.72128.1344152647794η1.0 P N0.75 P N0.5 P NCos Ø1.0 P N0.75 P N0.5 P NM NNm75.0 0.6775.0 0.57 3.7{ }70.0 0.4578.0 0.74{79.0 0.65}77.0 0.5079.5 0.76{80.0 0.66}78.0 0.5281.0 0.77{82.0 0.68}80.0 0.5583.5 0.80{83.5 0.74}83.0 0.6184.5 0.80{85.5 0.74}85.0 0.6186.5 0.80{87.0 0.74}86.0 0.6088.0 0.82{88.5 0.76}88.0 0.6489.0 0.83{89.5 0.77}89.0 0.6591.0 0.83{91.2 0.79}90.5 0.6791.8 0.84{92.3 0.79}91.7 0.6892.2 0.84{92.3 0.79}91.3 0.6492.6 0.84{92.9 0.80}92.5 0.6993.2 0.86{93.2 0.84}92.3 0.7593.6 0.86{93.6 0.84}92.5 0.7593.9 0.86{94.2 0.84}93.0 0.7594.2 0.86{94.6 0.84}93.50.755.17.510.114.820.226.536.249.471.597.5120143195240292357M AM N2.01.82.22.52.22.32.52.42.52.52.52.82.52.32.32.72.7I AI N4.24.45.15.65.55.87.07.57.57.77.78.47.57.57.37.77.7M KM SM NM N1.82.42.22.52.82.52.52.92.92.92.92.93.22.93.23.23.23.21.62.02.21.92.12.12.12.12.02.02.22.01.91.91.91.9M AM NY––––––0.750.700.700.650.650.800.750.70.70.750.75I AI NY––––––2.22.22.22.32.32.62.22.42.32.52.5M SM NY––––––0.650.600.600.500.500.650.600.550.550.550.55Jkgm 20.00150.00190.00280.00350.0080.090.0150.0270.0290.0680.0840.160.190.310.450.650.75L PAdB(A)4747484854545659596363626265666767(1) European and BS frame reference(2) European frame reference(3) BS frame reference8For performance curves and notes - see page 23


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Performance data1500 min –1 (4 pole)Rated powerFull load speed inrevolutions per minuteFrame referenceand sizeFull load current atrated voltageEfficiencyPower factorFull load torqueDirect on linestarting torque ratioDirect on linestarting current ratioDirect on linepull out torque ratioDirect on linepull up torqueStar deltastarting torque ratio (1)Star deltastarting current ratioStar deltapull up torqueRotor inertia WK 2Mean sound pressure level@ 1m on no loadP NkW(hp).75(100)90(125)110(150)132(175)150(200)160(215)185(250)200(270)225(300)250(335)280(375)315(420)355(475)400(535)nmin –114751475148014821485148714871485148714871487148714871487Type380 VAI N400 VA415 VAη1.0 P N0.75 P N0.5 P NCos Ø1.0 P N0.75 P N0.5 P NM NNm{ }94.7 0.87W-UDF280SNE (2)138 131 126W-DF250MN 94.8 0.85 486 2.4 7.4 2.7 0.72 2.3 0.54 1.4(3)93.5 0.7595.0 0.87W-UDF280MNE (2)165 157 151W-DF280SN { }95.1 0.85 583 2.5 7.4 2.8 2.0 0.75 2.4 0.55 1.6(3)93.8 0.7595.6 0.87W-UDF315SNE (2)201 191 184W-DF280MN { }95.5 0.85 710 2.4 7.7 2.6 2.0 0.70 2.5 0.5 3.2(3)94.0 0.7795.8 0.87W-UDF315MNE (2)241 229 2203.7W-DF315SN { }95.6 0.85 852 2.4 7.7 2.6 2.0 0.70 2.5 0.5(3)94.2 0.7795.9 0.88W-UDF315MN (2)270 257 2474.4W-DF315MN { }95.7 0.86 965 2.4 7.8 2.7 2.0 0.70 2.5 0.5(3)94.7 0.7895.9 0.88W-UDF315MP (2)288 274 2644.7W-DF315MP { }95.7 0.86 1029 2.4 7.8 2.7 2.0 0.70 2.5 0.5(3)94.7 0.7896.0 0.88W-UDF315LN (2)333 316 3055.5W-DF315LN { }95.8 0.86 1190 2.4 7.8 2.7 2.0 0.70 2.5 0.5(3)95.0 0.7896.0 0.88W-UDF315LN (2)360 342 3295.5W-DF315LN { }95.8 0.86 1286 2.3 7.6 2.6 1.9 0.65 2.4 0.45(3)95.0 0.7896.4 0.89W-UDF355SG (2)398 379 3658.2W-DF355SG { }96.2 0.86 1445 2.1 7.2 2.5 1.7 0.65 2.2 0.5(3)95.4 0.8096.6 0.89W-UDF355SJ (2)442 420 4059.5W-DF355SJ { }96.4 0.86 1605 2.1 7.2 2.5 1.7 0.65 2.2 0.5(3)95.6 0.8096.7 0.89W-UDF355SN (2)494 470 45310.6W-DF355SN { }96.5 0.87 1798 2.1 7.2 2.5 1.7 0.65 2.2 0.5(3)95.8 0.8196.8 0.89W-UDF355MJ (2)556 528 50911.9W-DF355MJ { }96.7 0.88 2023 2.1 7.2 2.5 1.7 0.65 2.2 0.5(3)96.0 0.8396.8 0.90W-UDF355MN (2)619 588 56713.2W-DF355MN { }96.7 0.89 2280 2.1 7.2 2.5 1.7 0.65 2.2 0.5(3)96.3 0.8496.9 0.90W-UDF355LN (2)697 662 63814.6W-DF355LN { }96.8 0.89 2569 2.1 7.2 2.5 1.7 0.65 2.2 0.5(3)96.5 0.84M AM NI AI NM KM SM NM N1.9M AM NYI AI NYM SM NYJkgm 2L PAdB(A)6969717173737373767676797979(1) European and BS frame reference(2) European frame reference(3) BS frame referenceFor performance curves and notes - see page 23 9


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Performance data1000 min –1 (6 pole)Rated powerFull load speed inrevolutions per minuteFrame referenceand sizeFull load current atrated voltageEfficiencyPower factorFull load torqueDirect on linestarting torque ratioDirect on linestarting current ratioDirect on linepull out torque ratioDirect on linepull up torqueStar deltastarting torque ratio (1)Star deltastarting current ratioStar deltapull up torqueRotor inertia WK 2Mean sound pressure level@ 1m on no loadP NkW(hp)0.37(0.5)0.55(0.75)0.75(1)1.1(1.5)1.5(2)2.2(3)3(4)4(5.5)5.5(7.5)7.5(10)11(15)15(20)18.5(25)22(30)30(40)37(50)45(60)nmin –1920920920940930950965960960975975975975975980980985TypeW-DF80MG (1)W-DF80MM (1)W-DF90SG (1)W-DF90LT (1)W-DF100LR (1)W-DF112MS (1)W-DF132SG (1)W-DF132ML (1)W-DF132MM (1)W-DF160MM (1)W-DF160LV (1)W-DF180LM (1)W-UDF200LGX (2)W-DF200LGX (3)W-UDF200LNX (2)W-DF200LNX (3)W-UDF225MN (2)W-DF225MN (3)W-UDF250MNE (2)W-DF250SN (3)W-UDF280SNE (2)W-DF250MN (3)380 VA1.331.862.233.44.55.87.59.512.916.823.8333946617488I N400 VA1.271.772.123.24.35.57.1912.31622.7313743587084415 VA1.271.772.123.24.35.57.1912.31622.7313542566781η1.0 P N0.75 P N0.5 P NCos Ø1.0 P N0.75 P N0.5 P NM NNm69.0 0.6168.0 0.51 3.8{ }64.0 0.4071.0 0.63{71.0 0.54}68.0 0.4174.0 0.69{74.0 0.59}72.0 0.4578.0 0.63{77.0 0.52}75.0 0.4179.0 0.64{79.0 0.54}77.0 0.4282.5 0.70{82.5 0.60}80.5 0.4786.0 0.71{86.0 0.64}84.0 0.5286.5 0.74{86.5 0.67}86.0 0.5587.0 0.74{87.0 0.67}86.5 0.5490.0 0.75{90.5 0.70}89.0 0.6091.0 0.77{91.0 0.72}89.5 0.6091.0 0.78{91.0 0.73}89.5 0.6091.2 0.80{91.2 0.76}90.0 0.6791.7 0.80{91.7 0.76}90.5 0.6792.7 0.80{92.7 0.76}91.7 0.6793.2 0.82{93.2 0.78}92.0 0.6993.4 0.83{93.3 0.79}92.30.715.77.811.215.422.129.839.854.773.4108147181215292361436M AM N2.02.02.22.82.02.82.22.12.01.82.02.42.32.32.72.72.5I AI N3.73.74.14.54.25.86.56.25.56.57.56.57.07.06.06.06.0M KM SM NM N1.82.22.32.43.02.32.82.72.62.52.82.82.82.02.02.12.12.01.82.02.52.02.31.71.61.61.71.92.22.82.81.81.81.8M AM NY––––––0.650.600.600.550.600.650.650.650.800.800.75I AI NY––––––2.12.02.02.12.52.22.32.32.02.01.9M SM NY––––––0.550.500.500.50.500.600.500.500.450.450.40Jkgm 20.00150.00210.00280.00390.0090.0140.0230.0270.0290.100.120.230.420.481.231.472.55L PAdB(A)4949656558545858585959596262636365(1) European and BS frame reference(2) European frame reference(3) BS frame reference10For performance curves and notes - see page 23


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Performance data1000 min –1 (6 pole)Rated powerFull load speed inrevolutions per minuteFrame referenceand sizeFull load current atrated voltageEfficiencyPower factorFull load torqueDirect on linestarting torque ratioDirect on linestarting current ratioDirect on linepull out torque ratioDirect on linepull up torqueStar deltastarting torque ratio (1)Star deltastarting current ratioStar deltapull up torqueRotor inertia WK 2Mean sound pressure level@ 1m on no loadP NkW(hp).55(75)75(100)90(125)110(150)132(175)150(200)160(215)185(250)200(270)225(300)250(335)280(375)315(420)nmin –1985985985985985985985985985985985990990Type380 VAI N400 VA415 VAη1.0 P N0.75 P N0.5 P NCos Ø1.0 P N0.75 P N0.5 P NM NNm{ }93.8 0.83W-UDF280MNE (2)107 102 98W-DF280SN 93.6 0.79 533 2.5 6.1 2.0 0.75 1.85 0.40 2.9(3)92.6 0.7194.3 0.84W-UDF315SNE (2)144 137 132W-DF280MN 94.1 0.80 727 3.0 7.0 2.6 2.1 0.90 2.1 0.60 5.0{ }(3)93.0 0.7294.5 0.84W-UDF315MNE (2)172 164 158W-DF315SN 94.3 0.80 872 3.0 7.0 2.6 2.1 0.90 2.1 0.60 6.0{ }(3)93.4 0.7294.8 0.85W-UDF315MN (2)207 197 1906.1W-DF315MN 94.7 0.81 1066 2.8 6.7 2.0 1.9 0.80 2.1 0.55{ }(3)93.8 0.7395.0 0.85W-UDF315LN (2)248 236 2277.3W-DF315LN 94.9 0.81 1280 2.8 6.7 2.0 1.9 0.80 2.1 0.55{ }(3)94.1 0.7395.5 0.85W-UDF355SG (2)281 267 25710W-DF355SG 95.4 0.83 1454 1.7 6.7 2.1 1.4 0.50 2.2 0.35{ }(3)94.5 0.7695.9 0.85W-UDF355SG (2)298 283 27310W-DF355SG 95.7 0.83 1551 1.7 6.7 2.1 1.4 0.50 2.2 0.35{ }(3)94.9 0.7695.9 0.85W-UDF355SJ (2)345 328 31611.1W-DF355SJ 95.8 0.83 1793 1.7 6.7 2.1 1.4 0.45 2.1 0.35{ }(3)95.1 0.7696.0 0.85W-UDF355SN (2)372 354 34112.2W-DF355SN 95.9 0.83 1939 1.7 6.7 2.1 1.4 0.45 2.1 0.35{ }(3)95.2 0.7696.0 0.85W-UDF355MJ (2)419 398 38413.6W-DF355MJ 96.0 0.83 2181 1.7 6.7 2.1 1.4 0.45 2.1 0.35{ }(3)95.4 0.7696.1 0.85W-UDF355MN (2)465 442 42615.2W-DF355MN 96.1 0.83 2424 1.8 7.0 2.2 1.5 0.48 2.2 0.40{ }(3)95.6 0.7696.2 0.85W-UDF355LJ (2)520 494 47616.9W-DF355LJ 96.2 0.83 2701 1.8 7.0 2.2 1.5 0.48 2.2 0.40{ }(3)95.7 0.7696.3 0.85W-UDF355LN (2)585 555 53518.6W-DF355LN 96.3 0.83 3038 1.8 7.0 2.1 1.5 0.48 2.1 0.40{ }(3)95.9 0.76M AM NI AI NM KM SM NM N1.9M AM NYI AI NYM SM NYJkgm 2L PAdB(A)65686870707474747477777777(1) European and BS frame reference(2) European frame reference(3) BS frame referenceFor performance curves and notes - see page 23 11


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Performance data750 min –1 (8 pole)Rated powerFull load speed inrevolutions per minuteFrame referenceand sizeFull load current atrated voltageEfficiencyPower factorFull load torqueDirect on linestarting torque ratioDirect on linestarting current ratioDirect on linepull out torque ratioDirect on linepull up torqueStar deltastarting torque ratio (1)Star deltastarting current ratioStar deltapull up torqueRotor inertia WK 2Mean sound pressure level@ 1m on no loadP NkW(hp)0.18(0.25)0.25(0.33)0.37(0.5)0.55(0.75)0.75(1)1.1(1.5)1.5(2)2.2(3)3(4)4(5.55.5(7.5)7.5(10)11(15)15(20)18.5(25)22(30)30(40)nmin –1695695700680690690690720720725725725730730730730735TypeW-DF80MG (1)W-DF80MM (1)W-DF90SG (1)W-DF90LM (1)W-DF100LR (1)W-DF100LS (1)W-DF112MS (1)W-DF132SM (1)W-DF132MR (1)W-DF160ME (1)W-DF160MM (1)W-DF160LV (1)W-DF180LM (1)W-UDF200LNX (2)W-DF200LNX (3)W-UDF225SN (2)W-DF225SN (3)W-UDF225MN (2)W-DF225MN (3)W-UDF250MNE (2)W-DF250SN (3)380 VA1.011.261.712.42.773.94.66.28.210.413.918.227.635435067I N400 VA0.961.21.632.32.643.74.45.97.89.913.217.326.333404764415 VA0.961.21.632.32.643.74.45.97.89.913.217.326.332394561η1.0 P N0.75 P N0.5 P NCos Ø1.0 P N0.75 P N0.5 P NM NNm55.0 0.4952.0 0.42 2.5{ }44.0 0.3459.0 0.51{56.5 0.43}49.0 0.3462.0 0.53{59.0 0.44}51.0 0.3464.0 0.54{62.0 0.44}55.0 0.3369.5 0.59{68.0 0.49}61.0 0.4071.5 0.60{70.5 0.51}68.0 0.3974.5 0.66{74.0 0.56}71.0 0.4482.5 0.65{83.0 0.57}80.0 0.4584.0 0.66{84.0 0.58}82.0 0.4586.0 0.68{86.0 0.64}84.0 0.5187.0 0.69{87.0 0.65}85.5 0.5288.0 0.71{88.0 0.65}86.0 0.5290.0 0.67{90.0 0.59}88.0 0.4890.0 0.73{90.0 0.66}88.5 0.5490.5 0.73{90.5 0.66}89.5 0.5491.5 0.74{91.5 0.66}89.0 0.5492.0 0.74{92.0 0.67}90.00.553.55.17.610.415.220.729.239.852.772.498.8143.9196242288390M AM N2.22.22.32.31.81.81.91.61.61.61.61.62.01.82.02.01.7I AI N2.72.93.03.33.23.24.05.05.05.55.76.04.55.85.56.06.0M KM SM NM N2.02.52.52.52.72.12.12.02.42.42.52.52.52.52.62.252.42.42.02.12.11.71.71.71.51.41.41.41.41.71.61.61.61.6M AM NY–––––––––0.50.50.50.630.450.50.450.4I AI NY–––––––––1.71.71.81.41.71.61.71.7M SM NY–––––––––0.450.450.450.550.350.350.350.35Jkgm 20.00170.00210.00280.00350.0090.00950.0150.0290.0310.090.110.140.240.480.751.231.47L PAdB(A)4646505053535757575353535860606262(1) European and BS frame reference(2) European frame reference(3) BS frame reference12For performance curves and notes - see page 23


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Performance data750 min –1 (8 pole)Rated powerFull load speed inrevolutions per minuteFrame referenceand sizeFull load current atrated voltageEfficiencyPower factorFull load torqueDirect on linestarting torque ratioDirect on linestarting current ratioDirect on linepull out torque ratioDirect on linepull up torqueStar deltastarting torque ratio (1)Star deltastarting current ratioStar deltapull up torqueRotor inertia WK 2Mean sound pressure level@ 1m on no loadP NkW(hp)37(50)45(60)55(75)75(100)90(125)110(150)132(175)150(200)160(215)185(250)200(270)225(300nmin –1735735740740740740740740740740740740Type380 VAI N400 VA415 VAη1.0 P N0.75 P N0.5 P NCos Ø1.0 P N0.75 P N0.5 P NM NNm{ }92.5 0.75W-UDF280SNE (2)81 77 74W-DF250MN 92.5 0.68 481 1.7 6.0 2.4 0.40 1.7 0.35 2.55(3)91.5 0.5693.0 0.75W-UDF280MNE (2)98 93 90W-DF280SN { }92.8 0.69 585 1.7 6.0 2.4 1.4 0.40 1.7 0.3 2.9(3)91.6 0.5793.5 0.75W-UDF315SNE (2)119 113 1095.0W-DF280MN { }93.3 0.70 710 2.5 6.0 2.0 1.5 0.60 1.7 0.35(3)92.0 0.5894.1 0.76W-UDF315MNE (2)159 151 1466.0W-DF315SN { }93.9 0.72 968 2.5 6.0 2.0 1.5 0.60 1.7 0.35(3)92.2 0.6094.4 0.77W-UDF315MN (2)188 179 1726.1W-DF315MN { }94.2 0.73 1161 2.4 6.0 2.0 1.8 0.65 1.7 0.45(3)93.4 0.6494.6 0.77W-UDF315LN (2)227 218 2107.3W-DF315LN { }94.4 0.73 1419 2.4 6.0 2.0 1.8 0.65 1.7 0.45(3)93.6 0.6495.1 0.77W-UDF355SJ (2)274 260 25112.2W-DF355SJ { }94.8 0.73 1703 1.6 6.1 2.0 1.3 0.40 1.8 0.3(3)93.6 0.6495.5 0.77W-UDF355SN (2)310 294 28413.6W-DF355SN { }95.3 0.73 1936 1.6 6.1 2.0 1.3 0.40 1.8 0.3(3)94.0 0.6495.5 0.77W-UDF355SN (2)331 315 30313.6W-DF355SN { }95.3 0.73 2065 1.6 6.1 2.0 1.3 0.40 1.8 0.3(3)94.0 0.6495.6 0.77W-UDF355MJ (2)383 364 35015.2W-DF355MJ { }95.4 0.73 2387 1.6 6.1 2.0 1.3 0.40 1.8 0.3(3)94.1 0.6495.6 0.77W-UDF355MN (2)413 393 37816.9W-DF355MN { }95.4 0.73 2581 1.6 6.1 2.0 1.3 0.40 1.8 0.3(3)94.3 0.6495.6 0.77W-UDF355LN (2)464 441 42518.6W-DF355LN { }95.4 0.73 2903 1.6 6.1 2.0 1.3 0.40 1.8 0.3(3)94.7 0.64M AM NI AI NM KM SM NM N1.6M AM NYI AI NYM SM NYJkgm 2L PAdB(A)636364646565727272747474(1) European and BS frame reference(2) European frame reference(3) BS frame referenceFor performance curves and notes - see page 23 13


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Dimensions- European & BS specificationsFoot, flange and face mounting - frames 80 - 180LIM B3IM 1001Mounting optionsIM B5/IM B35IM 3001/IM 2001Mounting optionsIM B14/IM B34IM 3601/IM 2101Mounting options14


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Foot, flange and face mounting - frames 80 - 180LTypeGeneralABCHKL (1) AA35ABACBBHAHDHD1Terminal boxTBW TBHKKW-DF80MW-DF90SW-DF90LW-DF100LW-DF112MW-DF132SW-DF132MW-DF160MW-DF160LW-DF180MW-DF180L125140140160190216216254254279279100100125140140140178210254241279505656637089891081081211218090901001121321321601601801801010101212121215151515278322322368382447447604604663663383834404747555564641571751751952302552553003003443441581751751972202602603153153553551271551551651822202203003003263261012121416171722222222---274305348348428428469469---2342573003003683684104101161161161161311311311741741741741161161161161311311311741741741741 X M201 X M201 X M202 X M202 X M252 X M252 X M252 X M322 X M322 X M322 X M32TypeIM B5 mountingM N PSTLAIM 1B14 mountingM N PSTLAW-DF80MW-DF90S/LW-DF100LW-DF112MW-DF132SW-DF132MW-DF160MW-DF160LW-DF180MW-DF180L165165215215265265300300300300130130180180230230250250250250200200250250300300350350350350121214.514.514.514.518.518.518.518.53.53.54444555512121212121213131515--130130165165215215--8095110110130130180180--120120160164200200250250--M6M8M8M8M10M10M12M12--333.53.53.53.544--9912.51313131313--TypeShaftDEFGGDEBEDDHGDW-DF80MW-DF90S/LW-DF100LW-DF112MW-DF132SW-DF132MW-DF160MW-DF160LW-DF180MW-DF180L19242828383842424848405060608080110110110110688810101212141415.52023.923.93333373742.542.567778888993240505070701001001001004555555555M6 x 16M8 x 19M10 x 22M10 x 22M12 x 28M12 x 28M16 x 36M16 x 36M16 x 36M16 x 36DGFTAPPED HOLE DHTO DIN 332(1)For vertically mounted, shaft down <strong>motors</strong> see table on page 4 for increase in overall length due to the fitting of an impact cover.For tolerance details and notes - see page 23 15


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Dimensions - European specificationFoot and flange mounting - frames 200 - 355LIM B3IM 1001Mounting optionsIM B5/IM B35IM 3001/IM 2001Mounting options16 (1) 8 holes at 22.5° for flanges to suit 225 frames and above to European specification


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Foot and flange mounting - frames 200 - 355LTypeGeneralA BCHK4 pole +L (1)2 poleAAABACBBHAHDHD 1TBWTerminal boxTBHKKL (1) 74W-UDF200LXW-UDF225SW-UDF225MW-UDF250MEW-UDF280SEW-UDF280MEW-UDF315SEW-UDF315MEW-UDF315MW-UDF315LW-UDF355SW-UDF355MW-UDF355L318356356406457457508508508508610610610305286311349368419406457457508500560630133149149168190190216216216216254254254200225225250280280315315315315355355355M16M16M16M20M20M20M24M24M24M24M24M24M2478787591598510651070114512151245131514851605165578784588598510651070111511851215128514151535158570707983838989898910010010038242642648254054059759759759771071071038141044844850850856356364064073273273235934937441943848948253353358362668675630252528353538383838272727501550 (2)570595 (3)655 (2)655 (2)8458458758759759759754444885105355955957447447767768748748741762202202202202203303303303303303303302202882882882882885265265265265265265262 x M32 + 1 x M202 x M40 + 1 x M202 x M40 + 1 x M202 x M50 + 1 x M202 x M50 + 1 x M202 x M50 + 1 x M202 x M63 + 1 x M202 x M63 + 1 x M202 x M63 + 1 x M202 x M63 + 1 x M202 x M63 + 1 x M202 x M63 + 1 x M202 x M63 + 1 x M20TypeW-UDF200LXW-UDF225SW-UDF225MW-UDF250MEW-UDF280SEW-UDF280MEW-UDF315SEW-UDF315MEW-UDF315MW-UDF315LW-UDF355SW-UDF355MW-UDF355LIM B5, IM B35 mountingM350400400500500500600600600600740740740N300350350450450450550550550550680680680P400450450550550550660660660660800800800S19191919191924242424242424T5555556666666LA19191925252529292929282828DGGDFTAPPED HOLE DHTO DIN 332TypeShaftDEF4 pole +GGDEBEDDEFG2 pole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x 42M20 x 42M20 x 42M20 x 42M20 x 42M20 x 42M20 x 42M20 x 42M20 x 42M20 x 42M24 x 50M24 x 50M24 x 50(1) For vertically mounted, shaft down <strong>motors</strong> see table on page 4 for increase in overall length due to the fitting of an impact cover.(2) add 25mm when cable entry is facing drive end(3) add 50mm when cable entry is facing drive endFor tolerance details and notes - see page 2317


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Dimensions - BS specificationFoot and flange mounting - frames 200 - 355LIM B3IM 1001Mounting optionsIM B5/IM B35IM 3001/IM 2001Mounting options18(1) 8 holes at 0° for flanges to suit 225 frames and above to British specification


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Foot and flange mounting - frames 200 - 355LTypeGeneralA BCHK4 pole +L (1)2 poleAAABACBBHAHDTerminal boxTBW TBHL (1) 382W-DF200LXW-DF225SW-DF225MW-DF250SW-DF250MW-DF280SW-DF280MW-DF315SW-DF315MW-DF315LW-DF355SW-DF355MW-DF355L318356356406406457457508508508610610610305286311311349368419406457508500560630133149149168168190190216216216254254254200225225250250280280315315315355355355M16M16M16M20M20M20M20M24M24M24M24M24M247878759159851030110011451215124513151485160516557878458859851030107011151185121512851415153515857470707979838389898910010010042642648248254054059759759771071071038141044844850850856356364064073273273235934937438141943848748353358362668675630252528283535383838272727501550 (2)570595 (3)625 (2)655 (2)810845875875970970970176220220220220220330330330330330330330220288288288288288526526526526526526526TypeW-DF200LXW-DF225SW-DF225MW-DF250SW-DF250MW-DF280SW-DF280MW-DF315SW-DF315MW-DF315LW-DF355SW-DF355MW-DF355LIM B5, IM B35 mountingM350400400500500500500600600600740740740N300350350450450450450550550550680680680P400450450550550550550660660660800800800S19191919191919242424242424T5555555666666LA19191925252525292929282828DGGDFTAPPED HOLE DHTO DIN 332TypeShaftDEF4 pole + 2 poleG GD EB ED D E F GGDEBEDDHW-DF200LXW-DF225SW-DF225MW-DF250SW-DF250MW-DF280SW-DF280MW-DF315SW-DF315MW-DF315LW-DF355SW-DF355MW-DF355L556060707080808585851001001001101401401401401701701701701702102102101618182020222222222228282849535362.562.57171767676909090101111121214141414141616161001251251251251601601601601602002002005101010105555555555555560606565656565757575110110110140140140140140140140140140140161616181818181818182020204949495353585858585867.567.567.51010101111111111111112121210010010012512512512512512512512512512555510101010101010101010M20 x 42M20 x 42M20 x 42M20 x 42M20 x 42M20 x 42M20 x 42M20 x 42M20 x 42M20 x 42M24 x 50M24 x 50M24 x 50(1) For vertically mounted, shaft down <strong>motors</strong> see table on page 4 for increase in overall length due to the fitting of an impact cover.(2) add 25mm when cable entry is facing drive end(3) add 50mm when cable entry is facing drive endFor tolerance details and notes - see page 23 19


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Technical information:MechanicalBearings and greasingarrangementsBearings are pre-packed with a grease typedependant on frame size and re-greasingfacility as detailed in table opposite:Standard and re-greasing facilitiesType80 - 180200 - 355StandardgreaseEA6 PolyureaEsso Unirex N3Re-greasingfacilityAvailableStandardBearing references and oil seals for horizontally-mounted <strong>motors</strong> onlyTypeBearings (1)Oil seals (2)EuropeanBSPolarityDrive endNon-drive endDrive endNon-drive endW-DF80MW-DF90S/LW-DF100LW-DF112MW-DF132S/MW-DF160M/LW-DF180M/LW-UDF200LXW-UDF225SW-UDF225MW-UDF250MEW-UDF280SEW-UDF280MEW-UDF315SEW-UDF315MEW-UDF315MW-UDF315LW-UDF355S/M/LW-DF80MW-DF90S/LW-DF100LW-DF112MW-DF132S/MW-DF160M/LW-DF180M/LW-DF200LXW-DF225SW-DF225MW-DF250SW-DF250MW-DF280SW-DF280MW-DF315SW-DF315MW-DF315LW-DF355S/M/LAllAllAllAllAllAllAllAllAllAll24 up24 up24 up24 up24 up24 up24 up24 up62042Z62052Z62062Z62062Z62082Z63092Z63102Z63126313631463146316631463186314631863166319631663196316631963166319N316N32462022Z62032Z62052Z62052Z63052Z63072Z63082Z631263136314631463166314631863146318631663196316631963166319631663196316632420 x 30 x 7 (3)25 x 35 x 7 (3)30 x 42 x 7 (3)30 x 42 x 7 (3)40 x 52 x 7 (3)45 x 60 x 8 (3)50 x 65 x 8 (3)60 x 80 x 8 (3)65 x 90 x 10 (4)70 x 90 x 10 (4)70 x 90 x 10 (4)80 x 110 x 10 (3)70 x 90 x 10 (4)90 x 120 x 12 (3)70 x 90 x 10 (4)90 x 120 x 12 (3)70 x 90 x 10 (4)90 x 120 x 12 (3)70 x 90 x 10 (4)90 x 120 x 12 (3)70 x 90 x 10 (4)90 x 120 x 12 (3)70 x 90 x 10 (4)90 x 120 x 12 (3)75 x 100 x 10 (4)115 x 145 x 14 (3)15 x 24 x 5 (3)17 x 28 x 6 (3)25 x 37 x 7 (3)25 x 37 x 7 (3)25 x 37 x 7 (3)35 x 47 x 7 (3)40 x 52 x 7 (3)60 x 80 x 8 (3)65 x 90 x 10 (4)70 x 90 x 10 (4)70 x 90 x 10 (4)80 x 110 x 10 (3)70 x 90 x 10 (4)90 x 120 x 12 (3)70 x 90 x 10 (4)90 x 120 x 12 (3)70 x 90 x 10 (4)90 x 120 x 12 (3)70 x 90 x 10 (4)90 x 120 x 12 (3)70 x 90 x 10 (4)90 x 120 x 12 (3)70 x 90 x 10 (4)90 x 120 x 12 (3)75 x 100 x 10 (4)115 x 145 x 14 (3)(1)Frame sizes 80 and 90 have bearings with CN clearances, frame sizes 100 to 355 have bearings with C3 clearance ‘medium’ series(2)Sizes given are in mm, and represent bore x outside diameter x widthMaterial: (3) Nitrile rubber (4) Silicon rubberGrease life expected at 80ºC bearing temperature x 10 3 hoursType3000 min -11500 min -1 1000 min -1 750 min -1EuropeanBSHorizontalVerticalHorizontalVertical Horizontal Vertical Horizontal VerticalW-DF80-90W-DF100-180LW-UDF200LXW-UDF225SW-UDF225MW-UDF250MEW-UDF280SEW-UDF280MEW-UDF315SEW-UDF315MEW-UDF315MW-UDF315LW-UDF355S/M/L (1)W-UDF355S/M/L (2)W-DF80-90W-DF100-180LW-DF200LXW-DF225SW-DF225MW-DF250SW-DF250MW-DF280SW-DF280MW-DF315SW-DF315MW-DF315LW-DF355S/M/L (1)W-DF355S/M/L (2)22.026.012.612.611.311.311.311.39.49.49.49.45.09.422.026.08.28.27.47.47.47.46.16.16.16.13.36.132.035.030.030.029.526.323.423.421.321.321.321.38.213.532.035.020.320.319.217.115.215.213.813.813.813.85.38.835.035.030.030.030.030.030.030.030.030.030.030.016.222.535.035.027.827.826.023.621.321.320.320.320.320.310.514.635.035.030.030.030.030.030.030.030.030.030.030.024.530.035.035.030.030.030.029.327.827.826.026.026.026.015.919.520(1) DE = Drive End(2) NDE = Non-Drive End


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Technical information:MechanicalAxial and radial loadsMaximum permissible external axial thrust and radial loads in Newtons (N)TypePolesLoadtowardsmotorHorizontal shaftLoadaway frommotorLoad towardsmotorShaft upLoad awayfrom motorVertical shaftLoad towardsmotorShaft downLoad awayfrom motorMaximumpermissible radial loadat end of shaft(standard mounting)W-DF80MW-DF90S/LW-DF100LW-DF112MW-DF132SW-DF132MW-DF160MW-DF160LW-DF180MW-DF180L2468246824682468246846824682468246833930328429644439834936978171056058076869054156513551269118610021253116799721682153202215092144212319731464271127492575226653950348449668463858960911011030880900108810108618851707162115381354160515191349266326482517200426392618246819593274331231382829321283260272421366309334743655506521715612463487126611681074869113010358582932265929052389295029822946243536673830378534695625305165287166826416561159110796398511701131979100318381779171115561794171815612002196017771250195118951669114424652426216618503623303163284764424014168397876436658508116596831486142713591204144213661209243724642410189424552487245119403104326732222906521483460472661606549574106397582684110359327838071618152014261221148213871210249721601977145021512095186913442665262623662050774729653662915854720747129512151145101812951202114110092114209519971609206819681600365037853626331636133738354432334374455643343979All figures are based on L10aah life of 20,000 hours21


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Technical information:MechanicalW-UDF200LXW-UDF225SW-UDF225MW-UDF250MEW-UDF280SEW-UDF280MEW-UDF315SEW-UDF315MEW-UDF315MW-UDF315LW-UDF355SW-UDF355MW-UDF355LMaximum permissible external axial thrust and radial loads in Newtons (N)246846824682468246824682468246824682468246824682468Poles54356058605557816692677064416729753076407293664090129391900765051024110846104006268977410582101367443103051119010797733710077109581034773981019211060106677055100081087210263611812994140381410657791252813148132145595123431293613002Horizontal shaftVertical shaftAll figures are based on L10aah life of 20,000 hoursBSframeLoadtowardsmotorLoadaway frommotor47755398539551216122620058716197699871086761610884188797841359119579101849738573691129920947468499965108501045767439737106181000768049852107201032764619668105329923552411454124981256651851098811608116745001108031139611462500555315457518359415935560660846745667363265837803083117927547289439423897751018014870482575921829990508657565476728419779856648006871583225050750182077587313687999387945523267511752375891734703869807046LoadtowardsmotorLoad awayfrom motor536161216215594171777371704270828099846381167209979410311992773521137712157117117355115341252412077895712719138101341790821304414131135109154128621397113578916413123142291360996921738919143192111005018055195331959910396182821979419860602167816875660177477941761276148631899586487741103881090510521794612039128191237378871219613186127399551130591415013757967613384144711385097481320214311139189758134631456913949102861892920683207511064419595210732113910990198222133421400LoadtowardsmotorLoad awayfrom motor434548714797452353715365503662136213614157945305743677177333487882818761831545697352804275955327795987108317506073328079745850707666837579824456716178677247254272597847791517325971598360491140549854405506Europeanframe51255588553652525963598256486602686868566501626281638477808756929260933693365824913696989216680494431004296306680912197349312688594821006696406603920798019367------------EuropeanframeBSframe512555885536525259635982564866026876685665016262816384778087589796271018297065795884293868919680494431004296306680912197349312688594821006696406606920798019367------------7541754175417541820282028202874589218921892189211134211342113428242171051710517105982517423174231742311342174141741417414113421741417414174141134217414174141741411342174141741417414126272753327533275331262727533275332753312627275332753327533EuropeanframeBSframe7541754175417541820282028202874589218921892189211416614166141668921141661416614166950317348173481734811342174141741417414113422088720887208871134220748207482074811342207482074820748126272753327533275331262727533275332753312627275332753327533Maximum permissible radial load at end of shaftShaft up Shaft down Standard ball bearing Roller bearingTypeW-DF200LXW-DF225SW-DF225MW-DF250SW-DF250MW-DF280SW-DF280MW-DF315SW-DF315MW-DF315LW-DF355SW-DF355MW-DF355L22


2204E Issue 1.2eW <strong>EEx</strong> <strong>nA</strong> <strong>non</strong>-<strong>sparking</strong> <strong>motors</strong>Performance data - page notesDOL starting(BS EN 60034-12 Design N)Typical speed/current curveTypical speed/torque curveStar delta starting(BS EN 60034-12 Design NY)Typical speed/current curveTypical speed/torque curve(I A ) Starting current(I N ) Full load current(M A ) Starting torque or ocked rotor torque(M S ) Pull up torque or run up torque(M K ) Pull out torque or breakdown torque(M N ) Full load torqueTorque/speed curves for specific <strong>motors</strong> canbe supplied on requestDuring the run up period in Star, there mustbe an adequate excess of motor torque overthe load torque. The change to Delta mustnot occur until the motor is near theoperating speed. Refer to <strong>Brook</strong> <strong>Crompton</strong>for running up against a load in excess of70% full load during Star Delta starting.Performance figures are subject to IECtolerances. Performance figures are based ona 400 volt winding. To calculate I N on specialvoltages, multiply the I N at 400 volts by thefollowing factors:Voltage 220346365420440500550Factor1.821.161.10.950.910.800.73Dimensions – page notesFlangeShaftAll dimensions in millimetresDim NIEC 72-1Annex C.I.7 Option 1Tol LimitsDim DBritish andEuropeanTol LimitsDrain holes are standard on frames 160-355 andon request for frames 80-132130 to 180230 to 250300350450550680Facej6h6h6h6h6h6h6+0.014–0.011+0.016–0.013+0.000-0.032+0.000-0.036+0.000-0.040+0.000-0.044+0.000-0.050IEC 72-1Annex C.I.7 Option 111 to 1819 to 2832 to 4855 to 8082 to 120Dj6j6k6m6m6+0.008–0.003+0.009–0.004+0.018+0.002+0.030+0.011+0.035+0.013GDFPlease note that 80 frame <strong>motors</strong> are onlyavailable as terminal box right or left.Cable entry can be arranged in any one of fourpositions at 90° intervalsNo eyebolts on frame sizes 80 (all poles) and 90(6 and 8 pole)Dimensions should not be used for installationpurposes unless specially endorsedB5 mounted <strong>motors</strong> have suffix ‘D’ in theframe reference, eg W-DF132MVX-D and B35mounted <strong>motors</strong> have suffix ‘H’ in the framereference, eg W-DF132MVX-HB14 mounted <strong>motors</strong> have suffix ‘C’ in theframe reference, eg W-DF132MVX-Cand B3/B14 mounted <strong>motors</strong> have suffix ‘H’in the frame reference, eg W-DF132MVX-HDim NTolLimits60 and 8095 and 110130 and 180j6j6j6+0.012–0.007+0.013–0.009+0.014–0.011GTAPPED HOLE DHTO DIN 33223


Rotating Electrical MachinesWorldwide sales and service networkEvery care has been taken to ensure the accuracy of the informationcontained in this publication, but, due to a policy of continuousdevelopment and improvement the right is reserved to supply productswhich may differ slightly from those illustrated and described in thispublication<strong>Brook</strong> <strong>Crompton</strong>St Thomas’ Road, HuddersfieldWest Yorkshire HD1 3LJ UKTel: +44 (0) 1484 557200Fax: +44 (0) 1484 557201E-mail: csc@brookcrompton.comInternet: www.brookcrompton.comPrinted in Englandgh111/08/02 2204E issue 1.2e© Copyright 2002. <strong>Brook</strong> <strong>Crompton</strong>. All rights reserved.