11.07.2015 Views

Multiwave 3000 (PDF) - MEP Instruments

Multiwave 3000 (PDF) - MEP Instruments

Multiwave 3000 (PDF) - MEP Instruments

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Multiwave</strong> <strong>3000</strong>Microwave Sample PreparationPlatform System::: Clear Solutions in Sample Preparation


<strong>Multiwave</strong> <strong>3000</strong>Simply the Best4 1400 W microwave power output via two magnetrons –ensures fast and direct heating4 Unpulsed microwave power over the whole range –for precise control of critical reactions4 High quality vessels and rotors –high reaction performance guaranteed4 Reliable pressure and temperature sensors –for enhanced reaction control and safety4 Remote sensor technology –installation-free for convenient handling4 Integrated high-performance cooling system –for reduced overall process times4 Full application support –assistance available whenever you need itIngenious sensor designPrecise control of the temperature is essential for reproducibleresults. <strong>Multiwave</strong> <strong>3000</strong> offers a dual solution: an accurateimmersing temperature probe in one reference vessel and an IRsensor underneath the cavity for sensing each vessel.4 Remote sensing – no installation, easy handling4 Protection against overheating with high boiling reagents4 Gas bulb thermometer – no microwave interference4 Simultaneous measurement of pressure and temperatureIntegrated forced-air cooling systemThe unique, patented (U.S. Patent No. 5,345,066) air gap designprovides effective heat transfer and cooling of vessels withinminutes after decomposition.4 Drastically reduced cycle times4 No external cooling required4 No handling of hot pressurized vessels4 Increased lifetime of key componentsPTFE-coated cavityDurable, industrial-quality components make the <strong>Multiwave</strong> <strong>3000</strong>suitable for harsh lab conditions. A multi-layer PTFE coatingefficiently protects its 66-liter stainless steel cavity.4 Maximum corrosion resistance4 Easy cleaning and maintenance4 Prepared for future system expansions


Features and Benefits4 Tool-free handling of rotors, vessels and sensors –unrivaled convenience for the operator4 Intuitive software –easy routine operation with documentation4 Multiple safety system –efficient user protection4 Optional programmable magnetic stirrer –for reduced reaction times and increased recoveries4 Broad range of accessories –maximum flexibility in the choice of configurations4 Versatile platform design –the same microwave oven for digestion, extraction,evaporation, drying, etc.Safety without compromiseSafety is one of the major benefits of the <strong>Multiwave</strong> <strong>3000</strong>.The sophisticated sensor technology for reaction control andnumerous active and passive safety measures open a newdimension of safety for sample preparation.4 Impact-resistant safety door with interlocks –the cavity is resealed automatically after a pressure release4 Multiple overpressure release devices4 Protection shields on rotors and vessels4 Certified safety system –only the <strong>Multiwave</strong> <strong>3000</strong> comes with ETL and GS(„approved safety“) certificatesStraightforward software solutionsThe built-in micro-controller of the <strong>Multiwave</strong> <strong>3000</strong> providesintelligent, comfortable, and intuitive software solutions.4 Comprehensive library of tested methods –ready-to-use applications for a wide range of samples,including US-EPA and ASTM methods4 Storage of up to 600 methods –adapt or create your own methods4 Multilingual user interface –English, Spanish, German, and French4 Easy operation under lab conditions –process parameters and online data at a glance4 Documentation at the push of a button –simple data transfer to a printer or to Microsoft Excel


Rotor 16SOLVExcellent ExtractionsRotor 16SOLV expands the possibilities of the <strong>Multiwave</strong> <strong>3000</strong>from inorganic to organic sample preparation, allowing you toreplace slow and tedious classical extraction methods.Extremely fast, safe and easy Microwave-Assisted Extraction(MAE) improves both the performance and throughput ofHPLC- or GC-based analysis.Extractions of PCBs, PAHs and hydrocarbons fromenvironmental and food samples, derivatization reactions priorto analysis or polymer extractions can be performed within 15to 30 minutes.For digestion and extractionThe <strong>Multiwave</strong> <strong>3000</strong> can be upgraded to a dual-useconfiguration by simply interchanging the screw caps.Benefits4 Significant reduction in extraction times4 Solvent consumption reduced to a minimum4 High-throughput extractions of up to 16 samplessimultaneously4 Meets requirements of US-EPA and ASTM methods4 Vessels are hermetically sealed and easy to handle4 Highest safety standards with GS and ETL certificates4 Temperature and pressure-controlled procedures in closedvessels – perfect extractions within 15 to 30 minutes4 Magnetic stirring for increased recoveryPassive heating elementsNon-polar solvents do not absorb microwave energysufficiently, but are required in many applications. The use ofpassive heating elements overcomes this drawback!4 Inert, stable, and reusable material4 No contamination of samples4 Excellent coupling efficiencyPressure filtration unitAn integrated filtration device for direct connection to theextraction vessels simplifies your sample work-up significantly.Applying pressure reduces the time required for filtration andrinsing to a few seconds.4 No loss of volatile analytes4 No exposure to solvent vapors


Rotor 8EVAP & Rotor 1DRYEvaporation & DryingVersatility in sample preparationThe <strong>Multiwave</strong> <strong>3000</strong> supports more than just digestion andextraction. Concentration of aqueous samples, drying ofsample material prior to digestion or removal of acids afterdecomposition can be done with the <strong>Multiwave</strong> <strong>3000</strong> in afraction of the time required by conventional techniques.Rotor 8EVAPThe evaporation rotor greatly simplifies and accelerates themicrowave-assisted evaporation of acids and concentration ofaqueous sample solutions.Prior to digestion, sample solutions can be reduced in volumein order to increase analyte concentrations and improvedigestion efficiency.After digestion, acids can be fumed off directly from reactionvessels under controlled clean room conditions. Acid vapors aresafely exhausted to an external scrubber and neutralized.4 Increased sample throughput4 No liquid transfer required4 Clean room conditions – no risk of contaminationScrubberRotor 8EVAP requires efficient acid fume and reaction gasexhaust. The optional scrubber washes and neutralizes thereagent vapors, which arise from microwave-heated acidevaporation and concentration processes. Efficient gas diffusershelp to wash out up to 95% of acids. Simply connect thescrubber to the <strong>Multiwave</strong> <strong>3000</strong> lead-through.Rotor 1DRYThe drying rotor is the ideal accessory for efficient handlingof samples prior to decomposition. Microwave drying takes aquarter of the time required by conventional methods, withoutcarbonization or contamination of samples. The integratedexhaust unit removes humidity and unwanted odors.


Special Solutionsfor Special ApplicationsAnton Paar has a long tradition of co-operation withinternational universities and research institutes. Our ongoingdevelopment and enhancement of innovative solutions ensuresthe satisfaction of all our customers' needs, including thosewith special requirements on a global basis.Oxygen combustionMicrowave-Induced Oxygen Combustion is an innovativemethod for sample preparation for all kinds of combustiblesolids such as wood, paper, coal, food or polymers.Volatile compounds such as halogens or several metalsreleased during this combustion process are trapped in anabsorption solution, which is subsequently analyzed via ionchromatography or atomic spectrometry.4 Replacement of steel combustion bombs4 Parallel combustion of up to 8 samples4 No handling of electrical connections or ignition wires4 No metal parts inside the combustion chamber –reduced risk of sample contaminationUV digestionMicrowave-Assisted UV Digestion is a powerful technique forultra-trace analysis of liquid samples with a high content oforganic compounds, e.g. seawater, effluents, sewage, bodyfluids or beverages.4 Microwave-energized UV lamps4 Minimum amounts of reagents required4 No need for concentrated mineral acids4 Low analytical blanksProtein hydrolysisProtein hydrolysis in liquid or gas phase is a well-establishedprocedure for sample preparation and structure analysis.Microwave protocols reduce the overall process time to lessthan one hour, compared to several hours of heating in classicalthermal methods.4 For milligram to gram amounts4 Disposable glass inserts4 No cross contamination4 Inert gas atmosphere applicable4 Accurate reaction control


Fotos: Croce & WirAnton Paar ® GmbHAnton-Paar-Str. 20A-8054 GrazAustria - EuropeTel: +43 (0)316 257-0Fax: +43 (0)316 257-257E-mail: info@anton-paar.comWeb: www.anton-paar.com<strong>Instruments</strong> for:Density & concentrationmeasurementRheometry & viscometrySample preparationMicrowave synthesisColloid scienceX-ray structure analysisRefractometryPolarimetryHigh-precision temperaturemeasurementSpecificationssubject to changewithout notice.01/09 B83IP01-D

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!