2<br />

Netzanschluss<br />

mains supply<br />

230 V / 50 Hz<br />

OK<br />

N L<br />

A B C D E<br />

NM 16A<br />

Netzsicherung unterhalb<br />

der Gehäuseabdeckung<br />

mains fuse below<br />

housing<br />

OK<br />

Klemmblock 4<br />

Terminal block 4<br />

A B C D E<br />

(F1)<br />

+<br />

-<br />

12V Akku +<br />

12V Akku -<br />

12V Akku<br />

12 V Akku<br />

Klemmblock 2<br />

Terminal block 2<br />

A<br />

B<br />

C<br />

D<br />

E<br />

(F2)<br />

Klemmblock 3<br />

Terminal<br />

block 3<br />

+ Gruppe 4 (F6)<br />

- GND<br />

+ Gruppe 3 (F5)<br />

- GND<br />

+ Gruppe 2 (F4)<br />

- GND<br />

+ Gruppe 1 (F3)<br />

- GND<br />

24 V Versorgung der Motorkreise<br />

max.8AjeGruppe, pro Netzmodul<br />

max. 16 A<br />

24 V power supply of motor circuits<br />

max. 8 A per group, max. 16 A per<br />

power supply unit<br />

Anschlüsse<br />

Die Lage der Klemme und die<br />

Verdrahtung mit den MZ2-Modulen<br />

entnehmen Sie bitte dem Verdrahtungsund<br />

Klemmenplan.<br />

Achtung: Jede Klemme ist mit<br />

maximal 12 A belastbar!<br />

Um die MZ2 Modulversorgung<br />

abzuschalten, muss der Stecker von<br />

Klemmblock 4 MZ2-Bus oder die<br />

Sicherung F1 abgezogen werden.<br />

Das Modul darf nur als Netzversorgung<br />

einer MZ2 Modulzentrale verwendet<br />

werden.<br />

Sicherungen<br />

Die Lage der Sicherungen entnehmen Sie<br />

bitte dem Verdrahtungs- und Klemmenplan.<br />

F1: 20 A Akkusicherung<br />

F2: 3A MZ2 Modulversorgung<br />

F3 - F6: 7,5 A (max.)<br />

Aktorenkreise 1- 4 (angepasst an die<br />

Aktoren, in Summe =16 A)<br />

Achtung: Ist an einem Aktorenkreis<br />

keine Last angeschlossen, so ist die<br />

Sicherung zu entfernen, sonst wird ein<br />

Sicherungsfehler angezeigt (siehe<br />

Blinkcodes).<br />

Klemmblock Batt.|OUT<br />

Klemme 1: Akku Anschluss (+)<br />

Klemme 2: Ausgang Aktorkreis 1 (+)<br />

[Gruppe 1]<br />

Klemme 3: Ausgang Aktorkreis 2 (+)<br />

[Gruppe 2]<br />

Klemme 4: Ausgang Aktorkreis 3 (+)<br />

[Gruppe 3]<br />

Klemme 5: Ausgang Aktorkreis 4 (+)<br />

[Gruppe 4]<br />

Klemme 6: Akku Anschluss (-)<br />

Klemme 7: Ausgang Aktorkreis 1 (-)<br />

[Gruppe 1]<br />

Klemme 8: Ausgang Aktorkreis 2 (-)<br />

[Gruppe 2]<br />

Klemme 9: Ausgang Aktorkreis 3 (-)<br />

[Gruppe 3]<br />

Klemme 10: Ausgang Aktorkreis 4 (-)<br />

[Gruppe 4]<br />

Klemmblock 2<br />

Klemme L: Netz (L1)<br />

Klemme N: Netz (N)<br />

Klemme PE: Netz (PE)<br />

Klemmblock 3:<br />

Akku Temperaturfühler [Temp. Sensor]<br />

Klemmblock 4:<br />

MZ2 BUS Anschluss [BUS]<br />

Klemme A: + 27 V [A]<br />

Klemme B: GND [Gnd]<br />

Klemme C: Reset [Bus1]<br />

Klemme D: Data [Bus2]<br />

Klemme E: Clock [Bus3]<br />

Adresswahlschalter<br />

Stellung 0: Modul abgeschaltet.<br />

Stellung 1-F(Hex.): Moduladressen 1 bis<br />

15 eingestellt (siehe PC Software<br />

Beschreibung) .<br />

Connections<br />

Please see the wiring and terminal plan for<br />

the position of the terminals and the wiring<br />

with the MZ2 modules.<br />

Warning: Each terminal can be<br />

loaded with a maximum of 12 A!<br />

To switch the MZ2 module supply off the<br />

plug must be removed from the terminal<br />

block 4 MZ3-bus or the F2 fuse. The<br />

module may only be used as power<br />

supply for a MZ2 module centre.<br />

Fuses<br />

Please see the wiring and terminal plan for<br />

the fuse positions.<br />

F1: 20 A Battery fuse<br />

F2: 3 A MZ2 module supply<br />

F3 - F6: 7.5 A (max.)<br />

Actuator circuits 1-4( adjusted to the<br />

actuators, in total =16 A)<br />

Warning:<br />

If no load is connected to<br />

an actuator circuit, the fuse is to be<br />

removed;<br />

otherwise a fuse error is<br />

displayed ( see<br />

flashing codes).<br />

Terminal block Batt.|OUT<br />

Terminal 1: Battery connection (+)<br />

Terminal 2: Output actuator circuit 1 (+)<br />

[Group 1]<br />

Terminal 3: Output actuator circuit 2 (+)<br />

[Group 2]<br />

Terminal 4: Output actuator circuit 3 (+)<br />

[Group 3]<br />

Terminal 5: Output actuator circuit 4 (+)<br />

[Group 4]<br />

Terminal 6: Battery connection (-)<br />

Terminal 7: Output actuator circuit 1 (-)<br />

[Group 1]<br />

Terminal 8: Output actuator circuit 2 (-)<br />

[Group 2]<br />

Terminal 9: Output actuator circuit 3 (-)<br />

[Group 3]<br />

Terminal 10: Output actuator circuit 4 (-)<br />

[Group 4]<br />

Terminal block 2<br />

Terminal L: Mains supply (L1)<br />

Terminal N: Mains supply (N)<br />

Terminal PE: Mains supply (PE)<br />

Terminal block 3:<br />

Battery temperature probe [Temp. Sensor]<br />

Terminal block 4:<br />

MZ2 BUS connection [BUS]<br />

Terminal A: + 27 V [A]<br />

Terminal B: GND [Gnd]<br />

Terminal C: Reset [Bus1]<br />

Terminal D: Data [Bus2]<br />

Terminal E: Clock [Bus3]<br />

Address selector switch<br />

Position 0: Module switched off.<br />

Position 1-F(Hex.): Module addresses 1<br />

to 15 set (see: PC Software description).