“ We developed our understanding of retinal diseases based onwhat we have been able to see, but imperfect visualization canyield only imperfect knowledge. Most major advances in ourunderstanding of retinal diseases were preceded by advances inimaging. Improving our imaging of the choroid and deeperstructures will illuminate a path to a new frontier of knowledge.”Deep Range Imaging OCTDr. Richard F. SpaideVitreous-Retina-Macula Consultants of New York


DEEP RANGE IMAGING<strong>Topcon</strong> OCT, the ultimate product chosen by professionalsCourtesy of Dr. R. F. Spaide and Dr. I. A. Barbazetto, Vitreous-Retina-Macula Consultants of New York“This patient had toxoplasmosis retinochoroiditis withcellular infiltrates in the vitreous. The advantage of sweptsource OCT is the tremendous ability to visualize everylevel of involvement. The cells in the vitreous, the retinalthickening with loss of laminations, and the choroidalthickening associated with the retinochoroiditis are allclearly demonstrated in a single scan.”DRI OCT-1 allows photography of IR/Enhanced IR/Red-free only.


IMAGING FUNCTIONEasy Capture12mm Wide ScanRegister / Select PatientWhen registering a patient, patient ocular parameterscan be inputted. Using the patient ocular parametersinformation, the software compensates the circlediameter during the circle scanning and the distancearea and volume during the 3D scanning, which ensuresaccurate scan performance and further analysis.* In case compensation magnification exceeds theacceptable range, the default value is applied.129mm66mmThe increased scan coverage of the macular area todisc afforded by the 12mm wide scan may be useful forthe evaluation of abnormalities observed in a broaderarea. Furthermore an instant single shot of the 12mmwide area will reduce patient fatigue and tremendouslyenhance examination workflow. Indulge yourself withwhat you can see now.Conventional 66mm, 3D ScanNew 129mm, 3D ScanSelecting Capture IconsVarious scan patterns of 3D / Cross / Radial / Circle /Lineprovide optimal scanning selections accordingto the patient disease condition.* The detailed information of the capture icons can be referred to in the lastparagraph of this catalog.1356784 102 12911Conventional 6mm, 12 Radial ScanNew 12mm, 12 Radial ScanCaptureThe photography mode can be selected from IR /Enhanced IR / Red-free images. The invisible scanlines and no requirement for flash reduces thepatient fatigue with IR / Enhanced IR imagecapturing. Operators may repeatedly capturethe patient eye as required.AnalysisThe captured image and analyzed data can beTMviewed from the FastMap installed computer.FastMap database and analysis softwareVisualization of the lamina cribrosaThe image on the left shows a Z-plain of optic disccupping. Less intensity laminar dot sign isobserved. DRI OCT-1 can even offer a possibilityof opening up new frontiers in the field of glaucomaresearch.* The lamina cribrosa was captured using the 3D 256256, 33mm protocol.* The image can appear differently based on individual operators.


ANALYSIS FEATURE7 Layers Segmentation7 Layers Thickness MapCaliper Function3D Volume RenderingThe captured 3D image can be magnified / narrowed, rotated, cropped, sliced and peeled to any x, y, z direction.Advanced layer detection algorithms and noise reduction software enables theability to detect 7 different layers of the retina. Thickness map and caliperfunctions allow for detailed analysis of the desired layer.Line 1 - Line 2Line 2 - Line 3Line 1 - Line 33D Macula 5126466mm4 Overlapping3D Disc 5126466mm4 OverlappingLine 1 - Line 4Line 6 - Line 7Line 1 - Line 7Line 1 - Line 5Peeling Cropping SlicingImport FunctionColor / FA / FAF images can be imported and compared with OCT images. By simply by double-clicking anoptional point of the OCT image and the imported image display area, the point location is shown as a greenline with a cross mark. Comparison across various retinal image modalities may better enhance our understandingof disease pathophysiology.Follow-up Examination & Comparison FunctionWhen referring to a past examined image, the software detects the same scanning location of the fundus imageduring the follow-up examination.* In the case of a patient with unstable fixation or serious diseases, the function may not work properly.


SPECIFICATIONSObservation & photography of fundusScan Pattern ExampleScan ModePicture AngleIR, Red-free43°Scan PatternMaximum ScanResolutionMaximum OverlappingScan CountMaximum ScanLength (mm)Operating DistancePhotographable Diameter of Pupil40.7mmNormal: 4.0mm or more3D512256129Small pupil diameter: 3.3mm or more512644129Fundus Image Resolution (on Fundus)10 lines/mm or more5 Line Cross1,024103212Observation & photography of fundus tomogramScan RangeHorizontal: 3 12mmVertical: 3 12mm12 RadialCircle1,024121,0243232123.4Scan SpeedScan Patterns100,000 A-scans per second3D scan (horizontal / vertical)Line1,0249612Linear scan (Line-scan/Cross-scan/Radial-scan)* More variable scan patterns available with a combination of different resolution, overlapping scan count and scan length.Circle scanLateral ResolutionIn-depth ResolutionPhotographable Diameter of Pupil20m8m2.5mm or moreObservation & photography of fundus image/fundus tomogramInternal Fixation TargetMatrix LCD (The display position can be changed andadjusted. The presenting method can be changed.)Electric RatingSource voltageFrequencyPower inputAC 100/110/120/220/230/240V50-60Hz200VADimensions / WeightDimensionsWeight545mm(W)×535mm(D)×585 615mm(H)35.0kg3D Optical Coherence Tomography


* PC and Camera sold seperately.Subject to change in design and/or specifications without advanced notice.IMPORTANTIn compliance with the terms of the Export Administration Regulation of theUnited States of America,this In order to product obtain may the not best be results available with in some this instrument, regions or countries. please be sure to review all user instructions prior to operation.<strong>Topcon</strong> Europe Medical B.V.Essebaan 11; 2908 LJ Capelle a/d IJssel; P.O. Box 145;2900 AC Capelle a/d IJssel; The Netherlands<strong>Topcon</strong> Phone: +31-(0)10-4585077; Europe Medical Fax: +31-(0)10-4585045B.V.Essebaan 11; 2908 LJ Capelle a/d IJssel; P.O. Box 145;E-mail: medical@topcon.eu; www.topcon-medical.eu2900 AC Capelle a/d IJssel; The NetherlandsPhone: +31-(0)10-4585077; Fax: +31-(0)10-4585045E-mail: medical@topcon.eu; www.topcon.eu<strong>Topcon</strong> Danmark<strong>Topcon</strong> Praestemarksvej Danmark 25; 4000 Roskilde, DanmarkPraestemarksvej 25; 4000 Roskilde, DanmarkPhone: Phone: +45-46-327500; +45-46-327500; Fax: Fax: +45-46-327555+45-46-327555E-mail: info@topcondanmark.dkwww.topcondanmark.dk<strong>Topcon</strong> Scandinavia A.B.Neongatan 2; P.O. Box 25; 43151 Mölndal, Sweden<strong>Topcon</strong> Phone: +46-(0)31-7109200; Scandinavia Fax: +46-(0)31-7109249A.B.Neongatan E-mail: medical@topcon.se; 2; P.O. Box 25; 43151 www.topcon.se Mölndal, Sweden<strong>Topcon</strong> Phone: +46-(0)31-7109200; España S.A. Fax: +46-(0)31-7109249E-mail: HEAD OFFICE; medical@topcon.se; Frederic Mompou, www.topcon.se 4;08960 Sant Just Desvern; Barcelona, SpainPhone: +34-93-4734057; Fax: +34-93-4733932E-mail: medica@topcon.es; www.topcon.es<strong>Topcon</strong> España S.A.HEAD OFFICE; Frederic Mompou, 4;08960 Sant Just Desvern; Barcelona, SpainPhone: +34-93-4734057; <strong>Topcon</strong> Fax: +34-93-4733932 ItalyViale dell’ Industria 60;E-mail: medica@topcon.es; www.topcon.es<strong>Topcon</strong> ItalyViale dell’ Industria 60; <strong>Topcon</strong> S.A.R.L.20037 Paderno Dugnano, (MI) ItalyPhone: +39-02-9186671; Fax: +39-02-91081091E-mail: topconitaly@tiscali.it; www.topcon.it<strong>Topcon</strong> France20037 Paderno Dugnano, (MI) ItalyPhone: +39-02-9186671; Fax: +39-02-91081091E-mail: topconitaly@tiscali.it; www.topconRua da Forte, 6-6A, L-0.22; 2790-072HEAD OFFICE; 89, rue de Paris; 92585 Clichy, Carnaxide; FrancePortugalPhone: +33-(0)1-41069494; Fax: +33-(0)1-47390251E-mail: topcon@topcon.fr; www.topcon.fr Phone: +351-210-994626; Fax: +351-210-938786www.topcon.pt<strong>Topcon</strong> Deutschland GmbHHanns-Martin-Schleyer Strasse 41;D-47877 Willich, GermanyPhone: (+49) 2154-885-0; Fax: (+49) 2154-885-177E-mail: med@topcon.de; www.topcon.deBAT A1; 3 route de la révolte, 93206 Saint Denis Cedex<strong>Topcon</strong> PortugalPhone: +33-(0)1-49212323; Rua Fax: da +33-(0)1-49212324Forte, 6-6A, L-0.22; 2790-072E-mail: topcon@topcon.fr; Carnaxide; www.topcon.fr Portugalwww.topcon-polska.plPhone: +351-210-994626; Fax: +351-210-938786www.topcon.ptTOPCON EUROPE MEDICAL<strong>Topcon</strong> Deutschland GmbHHanns-Martin-Schleyer Strasse 41;D-47877 Willich, GermanyPhone: (+49) 2154-885-0; Fax: (+49) 2154-885-177E-mail: med@topcon.de; www.topcon.de<strong>Topcon</strong> Portugal<strong>Topcon</strong> Polska Sp. z o.o.ul. Warszawska 23; 42-470 Siewierz; PolandPhone: +48-(0)32-670-50-45; Fax: +48-(0)32-671-34-05<strong>Topcon</strong> (Great Britain) Ltd.<strong>Topcon</strong> House; Kennet Side; Bone Lane; NewburyBerkshire RG14 5PX; United Kingdom<strong>Topcon</strong> Polska Phone: +44-(0)1635-551120; Sp. z o.o. Fax: +44-(0)1635-551170ul. Warszawska 23; 42-470 Siewierz; PolandE-mail: medical@topcon.co.uk, www.topcon.co.ukPhone: +48-(0)32-670-50-45; Fax: +48-(0)32-671-34-05www.topcon-polska.pl<strong>Topcon</strong> (Great <strong>Topcon</strong> Britain) IrelandLtd.<strong>Topcon</strong> House; Unit 276, Kennet Blanchardstown; Side; Bone Lane; Corporate NewburyPark 2Berkshire RG14 5PX; United KingdomBallycoolin; Dublin 15, IrelandPhone: +44-(0)1635-551120; Fax: +44-(0)1635-551170E-mail: medical@topcon.co.uk; Phone: +353-18975900; www.topcon.co.ukFax: +353-18293915<strong>Topcon</strong> IrelandE-mail: medical@topcon.ie; www.topcon.ieUnit 276, Blanchardstown; Corporate Park 2Ballycoolin;Dublin 15, IrelandPhone: +353-18975900; Fax: +353-18293915E-mail: medical@topcon.ie; www.topcon.ieItem code: 5250491 / Printed in Europe / 07.12