transducers

transducers transducers

11.07.2015 Views

Isolated Physiologic Pressure TransducerstransducersSpecifications (continued)PY2 60-0280 StandardIsolated Physiologic PressureTransducerPY2 60-0281 MiniatureIsolated PhysiologicPressure Transducer• Ideal for measuring pressure from venousthrough atrial ranges• Available in P23XL standard or P10EZminiature size• For use with:– Harvard Apparatus UK amplifiers– PLUGSYS modules– Grass amplifiers– Protocol propac monitor– Gould electronic 6600 and 4600 seriesof amplifiersThese solid state isolated pressure transducers measure from -50 to +300mmHg with a 100 mmHg shunt cal resistor. Safety is assured by anisolated sensing mechanism and plastic case. They are defibrillatorprotected. Select the transducer based on your required size, pressure andequipment to be used. Domes and interface cables must bepurchased separately.Transducer interface cables with integral connector are also soldseparately. This permits the same transducer to be connected to differentequipment. Simply purchase the necessary interface cable based on theequipment you will be using. The cable is 3.7 m (12 ft) long with a matingconnector for instrument specified. Replacement reusable polycarbonatedomes are available separately. They are supplied individually non-sterile(may be sterilized a limited number of times). Disposable diaphragmdomes are also available and are supplied in a box of 12,individually packaged.SpecificationsPressure Range-50 to +300 mmHgOver-Pressure Tolerance 10,000 mmHgBridge Resistance:Input Resistance1,000 W, nominalOutput Resistance350 W, nominalExcitation VoltageUp to 10 VAC or DC rms max., up to 5 kHzZero Offset±40 mmHg, max.Sensitivity 5 µV/V mmHg ±1%Thermal Coefficient:Of Sensitivity±0.1 %/°COf Zero±0.3 mmHg/°CElectrical Leakage> 2 µA at 120 VAC, 60 HzDefibrillator Withstand400 watt-seconds, max. across 50 W loadVolume DisplacementNon-LinearityHysteresisCable LengthOperating TemperatureWeight (Without Cable):Standard P23XLMiniature P10EZLength (Including Dome):Standard P23XLMiniature P10EZ0.04 mm3/100 mmHg pressure±1.5 mmHg/0 to 30 mmHg±0.1 mmHg/0 to 10 mmHg3.7 m (12 ft)20° to 40°C (68° to 104°F)15 g (1.46 oz)5 g (0.18 oz)40 mm (1.58 in)37 mm (1.46 in)Isolated Physiologic Pressure TransducerTransducer with Interface CableStandard Miniature InterfaceAmplifier P23XL P10EZ Cable OnlyHarvard Apparatus PY2 72-2461 PY2 72-2466 PY2 60-0298HA-HSE PY2 72-2880 PY2 72-2881 PY2 72-2882Grass PY2 72-2462 PY2 72-2467 PY2 60-0300Propac PY2 72-2463 PY2 72-2468 PY2 60-0297Gould 4600 PY2 72-2464 PY2 72-2469 PY2 60-0299Gould 6600 PY2 72-2465 PY2 72-2470 PY2 60-0296Order # ProductPY2 60-0280 P23XL Pressure Transducer without Connection Cable(Domes Ordered Separately, see below)PY2 60-0281 P10EZ Pressure Transducer without Connection Cable(Domes Ordered Separately, see below)PY2 72-2883 Interface Cable, Universal Connector to Tinned Leads(no connector), for Use with Other Equipment, MatingConnector RequiredPY2 60-0283 Reusable Polycarbonate Dome for P10EZ Miniature,Luer Lock Fitting, pkg. of 1PY2 60-0294 Disposable Diaphragm Dome for P10EZ Miniature,Rotating Luer Lock Fitting, pkg. of 12PY2 60-0290 Reusable Polycarbonate Dome for P23XL Standard Size,Linden Fitting, pkg. of 1PY2 60-0292 Disposable Diaphragm Dome for P23XL Standard Size,Rotating Luer Lock Fitting, pkg. of 12PY2 60-0293 Disposable Diaphragm Dome for P23XL Standard Size,Standard Linden Fitting, pkg. of 12For Isometric and Isotonic Transducers,see Physiology Section I.transducersCardiovascularHarvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.comJ7

TRA Series Blood Pressure Transducerstransducerstransducers CardiovascularReusable Pressure Transducer TRA021The Harvard Apparatus Research TRA021 is an economical, reusable bloodpressure transducer suitable for routine laboratory arterial and venousblood pressure measurements. The rugged construction and dome-typedesign makes the TRA 021 a good general use blood pressure transducer.The TRA021 is designed to work with the ISO 510 Amplifier System, seethe Physiology Section I, however custom connectors are available uponrequest. The Transducer is supplied with instruction manual andcalibration certificate.Disposable Pressure Transducer TRA023The Harvard Apparatus Research TRA023 is a disposable alternative tothe TRA021, reusable blood pressure transducer. Suitable for most arterialand venous blood pressure measurements, the in-line design allows lowercost while maintaining measurement accuracy.The TRA023 is designed to work with the ISO 510 Amplifier System, seethe Physiology Section I, however custom connectors are available uponrequest. The Transducer is supplied with instruction manual andcalibration certificate.SpecificationsRangeSensitivityBridge ResistanceExcitation VoltageVolume DisplacementTotal VolumeWeightSize-50 to 300 mmHg4 µV/V/mmHg350 W5 to 10 VDC0.05 mm3/100 mmHg0.25 ml85 g18 x 24 x 74 mmSpecificationsRange-50 to 300 mmHgSensitivity5 µV/V/mmHgExcitation Voltage2 to 5 VDCOperating Life> 500 hrsOrder # Model ProductPY2 76-0326 TRA023 Disposable Research Pressure TransducerOrder # Model ProductPY2 76-0411 TRA021 Reusable Research Pressure TransducerJ8Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com

TRA Series Blood Pressure Transducers<strong>transducers</strong><strong>transducers</strong> CardiovascularReusable Pressure Transducer TRA021The Harvard Apparatus Research TRA021 is an economical, reusable bloodpressure transducer suitable for routine laboratory arterial and venousblood pressure measurements. The rugged construction and dome-typedesign makes the TRA 021 a good general use blood pressure transducer.The TRA021 is designed to work with the ISO 510 Amplifier System, seethe Physiology Section I, however custom connectors are available uponrequest. The Transducer is supplied with instruction manual andcalibration certificate.Disposable Pressure Transducer TRA023The Harvard Apparatus Research TRA023 is a disposable alternative tothe TRA021, reusable blood pressure transducer. Suitable for most arterialand venous blood pressure measurements, the in-line design allows lowercost while maintaining measurement accuracy.The TRA023 is designed to work with the ISO 510 Amplifier System, seethe Physiology Section I, however custom connectors are available uponrequest. The Transducer is supplied with instruction manual andcalibration certificate.SpecificationsRangeSensitivityBridge ResistanceExcitation VoltageVolume DisplacementTotal VolumeWeightSize-50 to 300 mmHg4 µV/V/mmHg350 W5 to 10 VDC0.05 mm3/100 mmHg0.25 ml85 g18 x 24 x 74 mmSpecificationsRange-50 to 300 mmHgSensitivity5 µV/V/mmHgExcitation Voltage2 to 5 VDCOperating Life> 500 hrsOrder # Model ProductPY2 76-0326 TRA023 Disposable Research Pressure TransducerOrder # Model ProductPY2 76-0411 TRA021 Reusable Research Pressure TransducerJ8Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!