11.07.2015 Views

transducers

transducers

transducers

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

P75 Venous Pressure Transducer<strong>transducers</strong><strong>transducers</strong>CardiovascularBlood Pressure Transducer P75• For low pressure applications with liquids andgasses ±75mmHg• Excellent sensitivity and baseline stability• Applications include:– Venous blood pressure– Esophageal pressure with fluidfilled catheter– Perfusion pressure in isolated lung and liver– Perfusion pressure on perfused holloworgans like the esophagus• Robust construction, easy to fill, bubble freeThe P75 has a removable Macrolon ® dome with a pressure connection anda vent connection at the side, so that it can be filled free of air bubbles.The dome connections have a male Luer taper so that suitable stopcocks*can be attached. The transducer has a metal housing. The actual pressuresensor inside is made from ceramic and therefore has excellent resistanceto different media. The transducer’s rugged construction can withstandpressure overloads up to 4000 mmHg without damage. It works togetherwith any DC bridge amplifier (e.g., PLUGSYS TAM-A). See the PhysiologySection I.*Use one each of PY2 73-0096 three-way stopcock and PY2 73-0097 one-way stopcockSpecificationsPressure RangeVolume DisplacementLinearityLong-Term DriftOverload±75 mmHg (±100 cmH2O)0.06 mm3 /10 mmHg±0.15 mmHg±0.04 mmHg-760 (= vacuum) to 4000 mmHgMeasurement Media All gases and liquids which do not attack Macrolon ®Temperature Range 0° to 50°CZero DriftRange DriftElectrical Data:Supply VoltageCurrent LoadingSensitivityOutput ResistanceFrequency RangeConnection CableSuitable AmplifiersMechanical Data:PressureConnectionsWeightDimensions,H x W x DMounting Rod,OD x L±0.04 mmHg/10°C (0° to 50°C)±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C)5 V (4.5 to 5.5 V) DC only15 mA max.1 mV/mmHg, nominal300 Ω, nominal0 to 100 HzApprox. 1.5 m (4.9 ft) longAny bridge amp providing 5V DC excitation voltageLuer taper, male0.35 kg (0.8 lb)40 x 40 x 35 mm (1.57 x 1.57 x 1.38 in)8 x 70 mm (0.31 x 2.76 in)Order # ProductPY2 73-0020 Blood Pressure Transducer P75 forPLUGSYS TAM AmplifierPY2 73-0021 Blood Pressure Transducer P75 forHarvard Apparatus Transducer InterfacePY2 73-0022 Blood Pressure Transducer P75 for Grass AmplifiersPY2 73-0023 Blood Pressure Transducer P75 for Gould 6600 SeriesPY2 73-0024 Blood Pressure Transducer P75 for Gould 4600 SeriesPY2 73-0025 Replacement Dome for Venous Blood PressurePY2 73-3738 Blood Pressure Transducer P75 forADInstruments Bridge AmpJ6Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!