<strong>transducers</strong>Transducer Selection ChartBelow is a chart that details which amplifier is used for measurement ofa specific physiological parameter. Follow down the left hand column untilyou reach the parameter you want to measure and then move towards theright until you reach the column that displays the species you are studyingmay be a single transducer/sensor or multiple units to select from. Pleasesee individual pages for complete product details.Some typical cardiovascular setups are shown below.Transducer Selection ChartPhysiological SignalAmplifierLeft Ventricular MPVS Ultra PY2 72-9739Pressure-VolumeMouse and RatMPVS Ultra PY2 72-9724All animalsPressure-Volume MeasurementLeft Ventricular TAM-A PY2 73-0065Pressure (LVP) HEC-10D Cable PY2 72-9843Aortic Pressure (AP) TAM-A PY2 73-0065Venous Pressures (VP) TAM-A PY2 73-0065TAM-D PY2 73-1793<strong>transducers</strong> CardiovascularMPVS Ultra HardwareFor Blood Pressure Measurements2F Pressure-volumecatheter, SPR-838Pulmonary Artery pressure (PAP) TAM-A PY2 73-0065Aortic Flow (AF) TTFM PY2 73-0146Carotid Artery Flow (CAF) TTFM PY2 73-0146Aortic PressureAPT 300Femoral Artery Flow (FAF) TTFM PY2 73-0146Coronary Artery Flow (CF) TTFM PY2 73-0146TAM-ATAM-DVenous Pressure(P75)Pressure-VolumeCathetersECG ECGA PY2 73-0149EGM PY2 73-1778WLA PY2 73-1779For Blood Flow MeasurementsMAP BPA PY2 73-0153MAPM 3ch PY2 73-3080MAPM 6ch PY2 73-1780Sement Length, Wall Thickness EIM** PY2 73-0222SNM** PY2 73-0218Peripheral,Coronary FlowWall Thickening EIM** PY2 73-0222DDM** PY2 73-0785Temperature TCAM PY2 73-1792TTFMAortic FlowJ2Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


APT300 Blood Pressure Transducer<strong>transducers</strong>• Inexpensive• Reliable• Accurate• Low volume displacement• Suitable for virtually all arterial pressure applications• Easy to fill• Stopcocks included• Simple holder for rod mountingThe APT300 transducer is an inexpensive pressure transducer which canbe used to measure arterial blood pressures in all species, even on micewith a high heart rate.It can be used for measurement of arterial pressure in vivo as well asfor perfusion pressures in isolated perfused organs such as heart orkidney. It can also be used to measure isovolumetric left ventricular (usinga balloon) pressures in isolated hearts from mice up to rabbits or pigs.The transducer consists of a contact plate with cable and theexchangeable transducer head, which can easily be replaced. Contactplates with cables for different amplifier types are available.SpecificationsOperating pressure -300 to 300 mmHgOverpressure4000 mmHgSensitivity 5 µV/V/mmHg (±1%)Temperature coefficient < 0.1% / °CZerodrift < 0.2 mmHg / °CZero offset< 25 mmHgExcitation voltage 2 – 15 V DC (or AC up to 5kHz)Isolation against fluid > 5000 VOperating temperature 15° to 40°CStorage temperature -25° to 70°CVolume displacement < 0.04 mm 3/100 mmHgOutput impedance 356 Ohm ±1%Frequency response > 1 KHzCable length3 mPressure transducer APT300 with 3m cable and connector forPLUGSYS TAM AmplifierReplacement APT300 transducer headHolder for APT300 transducer,8mm rod, length 160mmReplacement cable with contact plateHolder for APT300 transducer,8mm rod, length 75mmOrder # ProductPY2 73-3862 APT300 Pressure transducer for PLUGSYS TAM AmplifierPY2 73-3863 APT300 Pressure Transducer for Harvard UKTransducer InterfacePY2 73-3864 APT300 Pressure Transducer for Grass AmplifiersPY2 73-3865 APT300 Pressure Transducer for Gould 6600 SeriesPY2 73-3866 APT300 Pressure transducer for ADInstrumentsBridge AmpPY2 73-3878 APT300 Pressure Transducer forDSI/PONEMAH 7700 AmplifierAccessoriesPY2 73-3860 Replacement Cable with Contact plate for PLUGSYSTAM AmplifierPY2 73-3861 Replacement APT300 Transducer HeadPY2 73-3868 Holder for APT300 Transducer, 8mm Rod, Length 160mmPY2 73-3869 Holder for APT300 Transducer, 8mm Rod, Length 75mmPY2 73-0566 Perspex Block Clamp to Mount Transducer on a RodPY2 73-0500 Stand with Block Clamp<strong>transducers</strong>CardiovascularHarvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.comJ5


P75 Venous Pressure Transducer<strong>transducers</strong><strong>transducers</strong>CardiovascularBlood Pressure Transducer P75• For low pressure applications with liquids andgasses ±75mmHg• Excellent sensitivity and baseline stability• Applications include:– Venous blood pressure– Esophageal pressure with fluidfilled catheter– Perfusion pressure in isolated lung and liver– Perfusion pressure on perfused holloworgans like the esophagus• Robust construction, easy to fill, bubble freeThe P75 has a removable Macrolon ® dome with a pressure connection anda vent connection at the side, so that it can be filled free of air bubbles.The dome connections have a male Luer taper so that suitable stopcocks*can be attached. The transducer has a metal housing. The actual pressuresensor inside is made from ceramic and therefore has excellent resistanceto different media. The transducer’s rugged construction can withstandpressure overloads up to 4000 mmHg without damage. It works togetherwith any DC bridge amplifier (e.g., PLUGSYS TAM-A). See the PhysiologySection I.*Use one each of PY2 73-0096 three-way stopcock and PY2 73-0097 one-way stopcockSpecificationsPressure RangeVolume DisplacementLinearityLong-Term DriftOverload±75 mmHg (±100 cmH2O)0.06 mm3 /10 mmHg±0.15 mmHg±0.04 mmHg-760 (= vacuum) to 4000 mmHgMeasurement Media All gases and liquids which do not attack Macrolon ®Temperature Range 0° to 50°CZero DriftRange DriftElectrical Data:Supply VoltageCurrent LoadingSensitivityOutput ResistanceFrequency RangeConnection CableSuitable AmplifiersMechanical Data:PressureConnectionsWeightDimensions,H x W x DMounting Rod,OD x L±0.04 mmHg/10°C (0° to 50°C)±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C)5 V (4.5 to 5.5 V) DC only15 mA max.1 mV/mmHg, nominal300 Ω, nominal0 to 100 HzApprox. 1.5 m (4.9 ft) longAny bridge amp providing 5V DC excitation voltageLuer taper, male0.35 kg (0.8 lb)40 x 40 x 35 mm (1.57 x 1.57 x 1.38 in)8 x 70 mm (0.31 x 2.76 in)Order # ProductPY2 73-0020 Blood Pressure Transducer P75 forPLUGSYS TAM AmplifierPY2 73-0021 Blood Pressure Transducer P75 forHarvard Apparatus Transducer InterfacePY2 73-0022 Blood Pressure Transducer P75 for Grass AmplifiersPY2 73-0023 Blood Pressure Transducer P75 for Gould 6600 SeriesPY2 73-0024 Blood Pressure Transducer P75 for Gould 4600 SeriesPY2 73-0025 Replacement Dome for Venous Blood PressurePY2 73-3738 Blood Pressure Transducer P75 forADInstruments Bridge AmpJ6Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


Isolated Physiologic Pressure Transducers<strong>transducers</strong>Specifications (continued)PY2 60-0280 StandardIsolated Physiologic PressureTransducerPY2 60-0281 MiniatureIsolated PhysiologicPressure Transducer• Ideal for measuring pressure from venousthrough atrial ranges• Available in P23XL standard or P10EZminiature size• For use with:– Harvard Apparatus UK amplifiers– PLUGSYS modules– Grass amplifiers– Protocol propac monitor– Gould electronic 6600 and 4600 seriesof amplifiersThese solid state isolated pressure <strong>transducers</strong> measure from -50 to +300mmHg with a 100 mmHg shunt cal resistor. Safety is assured by anisolated sensing mechanism and plastic case. They are defibrillatorprotected. Select the transducer based on your required size, pressure andequipment to be used. Domes and interface cables must bepurchased separately.Transducer interface cables with integral connector are also soldseparately. This permits the same transducer to be connected to differentequipment. Simply purchase the necessary interface cable based on theequipment you will be using. The cable is 3.7 m (12 ft) long with a matingconnector for instrument specified. Replacement reusable polycarbonatedomes are available separately. They are supplied individually non-sterile(may be sterilized a limited number of times). Disposable diaphragmdomes are also available and are supplied in a box of 12,individually packaged.SpecificationsPressure Range-50 to +300 mmHgOver-Pressure Tolerance 10,000 mmHgBridge Resistance:Input Resistance1,000 W, nominalOutput Resistance350 W, nominalExcitation VoltageUp to 10 VAC or DC rms max., up to 5 kHzZero Offset±40 mmHg, max.Sensitivity 5 µV/V mmHg ±1%Thermal Coefficient:Of Sensitivity±0.1 %/°COf Zero±0.3 mmHg/°CElectrical Leakage> 2 µA at 120 VAC, 60 HzDefibrillator Withstand400 watt-seconds, max. across 50 W loadVolume DisplacementNon-LinearityHysteresisCable LengthOperating TemperatureWeight (Without Cable):Standard P23XLMiniature P10EZLength (Including Dome):Standard P23XLMiniature P10EZ0.04 mm3/100 mmHg pressure±1.5 mmHg/0 to 30 mmHg±0.1 mmHg/0 to 10 mmHg3.7 m (12 ft)20° to 40°C (68° to 104°F)15 g (1.46 oz)5 g (0.18 oz)40 mm (1.58 in)37 mm (1.46 in)Isolated Physiologic Pressure TransducerTransducer with Interface CableStandard Miniature InterfaceAmplifier P23XL P10EZ Cable OnlyHarvard Apparatus PY2 72-2461 PY2 72-2466 PY2 60-0298HA-HSE PY2 72-2880 PY2 72-2881 PY2 72-2882Grass PY2 72-2462 PY2 72-2467 PY2 60-0300Propac PY2 72-2463 PY2 72-2468 PY2 60-0297Gould 4600 PY2 72-2464 PY2 72-2469 PY2 60-0299Gould 6600 PY2 72-2465 PY2 72-2470 PY2 60-0296Order # ProductPY2 60-0280 P23XL Pressure Transducer without Connection Cable(Domes Ordered Separately, see below)PY2 60-0281 P10EZ Pressure Transducer without Connection Cable(Domes Ordered Separately, see below)PY2 72-2883 Interface Cable, Universal Connector to Tinned Leads(no connector), for Use with Other Equipment, MatingConnector RequiredPY2 60-0283 Reusable Polycarbonate Dome for P10EZ Miniature,Luer Lock Fitting, pkg. of 1PY2 60-0294 Disposable Diaphragm Dome for P10EZ Miniature,Rotating Luer Lock Fitting, pkg. of 12PY2 60-0290 Reusable Polycarbonate Dome for P23XL Standard Size,Linden Fitting, pkg. of 1PY2 60-0292 Disposable Diaphragm Dome for P23XL Standard Size,Rotating Luer Lock Fitting, pkg. of 12PY2 60-0293 Disposable Diaphragm Dome for P23XL Standard Size,Standard Linden Fitting, pkg. of 12For Isometric and Isotonic Transducers,see Physiology Section I.<strong>transducers</strong>CardiovascularHarvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.comJ7


TRA Series Blood Pressure Transducers<strong>transducers</strong><strong>transducers</strong> CardiovascularReusable Pressure Transducer TRA021The Harvard Apparatus Research TRA021 is an economical, reusable bloodpressure transducer suitable for routine laboratory arterial and venousblood pressure measurements. The rugged construction and dome-typedesign makes the TRA 021 a good general use blood pressure transducer.The TRA021 is designed to work with the ISO 510 Amplifier System, seethe Physiology Section I, however custom connectors are available uponrequest. The Transducer is supplied with instruction manual andcalibration certificate.Disposable Pressure Transducer TRA023The Harvard Apparatus Research TRA023 is a disposable alternative tothe TRA021, reusable blood pressure transducer. Suitable for most arterialand venous blood pressure measurements, the in-line design allows lowercost while maintaining measurement accuracy.The TRA023 is designed to work with the ISO 510 Amplifier System, seethe Physiology Section I, however custom connectors are available uponrequest. The Transducer is supplied with instruction manual andcalibration certificate.SpecificationsRangeSensitivityBridge ResistanceExcitation VoltageVolume DisplacementTotal VolumeWeightSize-50 to 300 mmHg4 µV/V/mmHg350 W5 to 10 VDC0.05 mm3/100 mmHg0.25 ml85 g18 x 24 x 74 mmSpecificationsRange-50 to 300 mmHgSensitivity5 µV/V/mmHgExcitation Voltage2 to 5 VDCOperating Life> 500 hrsOrder # Model ProductPY2 76-0326 TRA023 Disposable Research Pressure TransducerOrder # Model ProductPY2 76-0411 TRA021 Reusable Research Pressure TransducerJ8Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


Electronic Pressure Calibrators<strong>transducers</strong>Electronic Pressure CalibratorsThe built-in pressure meter measures the set pressure accurately andindicates it in digital form. Since the generated pressure is identical at thebuilt-in pressure meter and at the test object, the pressure measured by thetest object corresponds exactly to the pressure indicated by the KAL 84.Models with different pressure ranges are available. Each model has anapplication-specific range (range 1) and can be switched to acorresponding SI range (range 2) in Pascal (Pa) or Kilopascal (kPA).Specifications• Maintenance free precision pressure generation• 4 units available:– 0 to 200 mmHg– 0 to 300 mmHg– 0 to 20 mmH 2O– 0 to 200 mmH 2O• Calibration certificate on requestThe calibrator KAL 84 is used for calibrating pressure sensors. It represents acombination of a pressure generator (hand pump) and a pressure meter withdigital display. The instrument provides a simple means for testing andcalibrating both pressure sensors and complete pressure measuring equipment.High accuracy and excellent reproducibility together with an especiallyrugged construction provide the unit with all the properties required forlaboratory applications.After the unit has been switched on and connected to the pressure sensor to becalibrated (test object), the required pressure is set with the small hand-wheel.RangeLinearityHysteresisOverpressure LimitResponse TimeAnalog OutputTemperature Range:NominalOperatingPressure ConnectionsPower SupplyDimensions, H x W x DWeightOptional CertificateMeasurement and calibration range for appropriatemodel (see table below)±0.5% FS ±1 digit for mercury models, ±1% FS ±1 digitfor water models0.1% FS200% FS for mercury models 500% FSfor water modelsTE = 20 ms, time constant can be switched to 0.1 secor 1 sec0 to 1 V for 100% nominal range, load resistance atleast 2 kΩ+10°C to +50°C0°C to +60°C6.5 mm OD for 5 mm ID tubing9 V rechargeable battery, mains adapter100 x 260 x 180 mm (3.9 x 10.2 x 7.1 in)Approx. 3 kg (6.6 lb)Linearity test certificate, DKD (German calibrationservice, see below)Order # ProductPY2 73-0977 Calibration Certificate with KAL84 PurchasePY2 73-2918 Recalibration of KAL84 with Certificate(Requires Return of Unit)<strong>transducers</strong>CardiovascularElectronic Pressure Calibrators115 VAC, 60 Hz 230 VAC, 50 Hz Model Liquid Range 1 Range 2 Used for Calibration of:PY2 73-0012 PY2 73-0013 KAL 84 H Mercury 0 to 199.9 mmHg 0 to 26.66 kPa Blood Pressure TransducersPY2 73-0014 PY2 73-0015 KAL 84 SH Mercury 0 to 300.0 mmHg 0 to 39.99 kPa Blood Pressure TransducersPY2 73-0016 PY2 73-0017 KAL 84 L Water 0 to 19.99 mmH 2O 0 to 196.0 Pa Low-Range Differential Pressure TransducersPY2 73-0018 PY2 73-0019 KAL 84 M Water 0 to 199.9 mmH 2O 0 to 1960 Pa Low-Range Differential Pressure TransducersHarvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.comJ9


<strong>transducers</strong>NEW Millar MPVS Ultra Pressure-Volume SystemsMPVS Ultra Hardware2F Pressure-Volume Catheter, SPR-838<strong>transducers</strong> CardiovascularThe MPVS Ultra simultaneously and continuously measures high-fidelityleft ventricular pressure and relative volume from the intact beating heartsof animals ranging in size from transgenic mice to domestic livestock.Using the MPVS Ultra, cardiovascular pressure and volume signals can beplotted against each other in real time, generating the characteristicpressure-volume (P-V) loops that are an excellent illustration of thecardiac cycle in normal or diseased conditions of the living heart.MPVS Ultra is the only complete solution for measuring real-timecardiovascular pressure and volume in small and large animal models with anindustry-leading seven volume segments.Millar catheters and hardware integrate seamlessly with HarvardApparatus Physiology systems to create a complete CardiovascularPhysiology solution.MPVS Ultra Components• MIKRO-Tip ® P-V catheters• P-V signal conditioning hardware with innovativesoftware-controlled user interface• PVAN Ultra data analysis software• Rho cuvette for volume calibration• Data acquisition system (Choose fromavailable Harvard Apparatus DAQsystems in Physiology Section I)• Connection cables• Computer (not included)Features• Real-time pressure-volume measurement atthe source• High-frequency response• No motion artifact or damping of pressure signal• Minimally invasive• Small and large animal capabilities• Software controlled user interface• Comprehensive, easy-to-use analysis softwareApplications• Baseline P-V loop analysis• Occlusion P-V loop analysis• Phenotyping gene manipulations• Cardiac hypertrophy• Cardiac failure• Cardiovascular remodeling• Toxicology• Pharmacology (rapid drug screening)• Cardiac resynchronization therapy• Surgical interventions• Ischemia/reperfusion studies✐NOTE:Please contact your local HarvardApparatus Representative or our TechnicalSupport Team to configure a system to yourrequirements.J10Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


<strong>transducers</strong>NEW Millar MPVS Ultra Pressure-Volume Systems(continued)1.4F SPR-839210F SPR-838Enlargement of tips of Pressure-Volume CathetersOrder # ProductMPVS Ultra Single Segment for Mouse & Rat use onlyPY2 72-9739 MPVS Ultra Single Segment Unit with Control Interface SoftwarePY2 72-9834 MPVS Ultra Upgrade (Converts Single Segment Unit to Multi Segment Unit)MPVS Ultra Multi Segment for all animal modelsPY2 72-9724 MPVS Ultra with Control Interface SoftwareAccessoriesPY2 72-9835 Ultra Cable Pack 4 ft (CEC-4E PV Cable, PEC-4D)PY2 72-9727 Ultra Cable Pack 10 ft (CEC-10E PV Cable, PEC-10D)PY2 72-9728 BNC Cable Pack-PowerLab (10 BNC-BNC 9 in, 1 BNC-BNC 1 ft, 2 BNC-BNC 3 ft)PY2 72-9836 BNC Cable Pack-STD. (13 BNC-BNC 3 ft)PY2 72-9726 RHO CUVETTE w/ Well and Cable as one unitPY2 72-9725 PVAN Ultra SOFTWARE CDPY2 72-9837 EPC-10UT - ECG Cable 10 ft unterminatedPY2 72-9838 CEC-4E - PV Extension Cable, 4 ftPY2 72-9826 PEC-4D - Pressure Extension Cable, Redel - Low Profile 4 ftPY2 72-9839 CEC-10E - PV Extension Cable, 10 ftPY2 72-9816 PEC-10D - Pressure Extension Cable - Low Profile 10 ft<strong>transducers</strong>Cardiovascular✐NOTE:Please contact your local HarvardApparatus Representative or our TechnicalSupport Team to configure a system to yourrequirements.Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.comJ11


NEW Millar MIKRO-Tip P-V Catheters<strong>transducers</strong>MIKRO-Tip P-V catheters combine pressure sensors and electrodes for simultaneous high-fidelity pressure-volume measurements from a single instrument.<strong>transducers</strong> CardiovascularOrder # Model ProductSingle Segment Catheters - Mice, RatsPY2 72-9740 PVR-1030 1F, 4E 3.0 mm spacing, 4.5 cm, Non-repairablePY2 72-9722 PVR-1035 1F, 4E 3.5 mm spacing, 4.5 cm, Non-repairablePY2 72-9721 PVR-1045 1F, 4E 4.5 mm spacing, 4.5 cm, Non-repairablePY2 72-9723 SPR-839 1.4F, 4E 4.5 mm spacing, 4.5 cmPY2 72-9738 SPR-839 1.4F, 4E 4.5 mm spacing, 4.5 cm, NO REPAIRPY2 72-9741 SPR-853 1.4F, 4E, 4.0mm, TAPERPY2 72-9742 SPR-848 1.4F, 4E 4.5 mm spacing, Dual sensor, APICALPY2 72-9743 SPR-864 1.4F, 4E 4.5 mm spacing, Dual sensor, CAROTIDPY2 72-9744 SPR-847 1.4F, 4E 9.0 mm spacing, 15 cmPY2 72-9745 SPR-869 2F, 4E 6.0 mm spacing, 15 cmPY2 72-9745NR SPR-869 2F, 4E 6.0 mm spacing, 15 cm, NO REPAIRPY2 72-9736 SPR-838 2F, 4E 9.0 mm spacing, 15 cmPY2 72-9737 SPR-838 2F, 4E 9.0 mm spacing, 15 cm, NO REPAIRPY2 72-9746 SPR-878 2F, 4E 12.0 mm spacing, 15 cmPY2 72-9747 SPR-858 2F, 4E 14.0 mm spacing, 15 cmPY2 72-9748 SPR-901 2F 2P, 4E 9.0 mm spacing, 15 cm, CAROTIDPY2 72-9749 SPR-902 2F 2P, 4E 9.0 mm spacing, 15 cm, APICAL2F Multi Segment Catheters - Large RatsPY2 72-9750 SPR-931 2F, Single Field, 6E 3.0mm spacing, Straight, 12.5 cmPY2 72-9751 SPR-932 2F, Single Field, 8E 3.0mm spacing, Straight, 12.5 cm3F Multi Segment Catheters - Rabbits/CatsPY2 72-9752 SPR-923-1 3F, Single Field, 10E 3.0mm spacing, Straight, 105 cmPY2 72-9753 SPR-923-3 3F, Single Field, 10E 4.5mm spacing, Straight, 105 cmPY2 72-9754 SPR-877 3F, 10E Dual Field 2.5 mm spacing, Straight, 120 cmPY2 72-9755 SPR-855 3F, 10E Dual Field 4.0 mm spacing, Straight, 120 cmPY2 72-9756 SPR-856 3F, 10E Single Field 4.5 mm spacing, Straight, 120 cmPY2 72-9757 SPR-889 3F, 10E Single Field 3.0 mm spacing, U-Tip, 80 cmPY2 72-9758 SPR-894 3F, 10E Dual Field 4.0 mm spacing, U-Tip, 80 cmPY2 72-9759 SPR-845 3F, 8E Single Field 3.0 mm spacing, U-Tip, 120 cmPY2 72-9760 SSD-1033 3F, 8E Single Field 4.3 mm spacing, U-Tip, 140 cm5F Multi Segment PV Catheters - Dog/Pig/SheepPY2 72-9761 SPR-550-2 5F, 12E Dual Field 9.0 mm spacing, Pigtail, 125 cmPY2 72-9762 SPR-550-5 5F, 12E Dual Field 7.0 mm spacing, Pigtail, 125 cmPY2 72-9763 SPR-550-7 5F, 12E Dual Field 10.0 mm spacing, Pigtail, 125 cmPY2 72-9764 SPR-550-8 5F, 10E Single Field 7.0 mm spacing, Pigtail, 125 cmPY2 72-9765 SPR-554-5 5F, 12E Dual Field, 7.0 mm spacing, Straight, 125 cmPY2 72-9766 SPR-554-11 5F, 10E Dual Field, 7.0 mm spacing, Straight, 125 cmPY2 72-9767 SPR-560-1 5F, 12E Dual Field, 7.0 mm spacing, Pigtail, 125 cmPY2 72-9729 SPR-562-1 6F 2P, 12E Dual Field 7.0 mm spacing, Pigtail 125 cmPY2 72-9769 SPR-570-2 7F, 12E Dual Field, 9 mm spacing, Pigtail 125 cmPY2 72-9770 SPR-570-7 7F, 12E Dual Field, 10 mm spacing, Pigtail 125 cmPY2 72-9771 SPR-570-9 7F, 8E Single Field, 8.5 mm spacing, Pigtail 125 cmPY2 72-9772 SPR-572-7 7F, 12E Dual Field, 10 mm spacing, Pigtail 125 cmRAT/MOUSE SELECTABLE SEGMENT - For use with MPVS-300/400 onlyPY2 72-9768 SPR-819 1.4F, 6E, 9.0 mm/14.0 mmPY2 72-9773 SPR-866 1.4F, 6E, 4.0 mm/6.0 mmJ12Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


<strong>transducers</strong>NEW Combination Catheter MAP-Stimulation 7F• For intraventricular MAP recording• For pacing• Accurate• Steerable unidirectional up to 90° curveThis new combination catheter is used for in-vivo studies in anesthetizeddogs or pigs. The handle allows to curve unidirectionaly up to 90° thesteerable end of the catheter to place the tip optimally inside theventricle on the heart wall. The two stimulation electrodes allow pacingand the recording electrodes to record the intraventricular MAP.SpecificationsMAP ElectrodeReference ElectrodeStimulation ElectrodesCatheter SizeCatheter LengthCatheter FeatureConnectorsCable LengthCentral, axial Ag/AgCl MAP-electrode, D=1.5 mm,protruding by 1mm (Yellow connecting line)Lateral Ag/AgCl Reference electrode, D=1 mm, 5 mmproximal to the tip (Blue connecting line)2 lateral opposite Ag Stimulation electrodes,D=1 mm, 3 mm proximal to the tip (Green and Redconnecting lines)7F (2.33 mm, 0.091 in)110 cm (43.31 in)Stearable, 90° Curve, Unidirectional2 mm Banana Male Connectors60 cm (23.62 in)View of the catheter: the catheter (blue) on the right of the handle has a length of110cm and a diameter of 7F (2.33mm). At the end of the catheter the light blue 90°stearable part of the catheter is visible. The distal white end tip includes 4 electrodes.View of the curved (unidirectionalstearable catheter end. (the MAPandthe Reference- electrode arevisibleSchematic representation of thedistal tip. (shows also the codingcolors to the cable connection)Order # ProductPY2 73-3872 Combination Catheter MAP-Stimulation7F for in-vivo studiesPY2 73-3356 Input Cable with 2mm Sockets for BPA(for MAP electrodes)PY2 73-3985 Bipolar Connecting Cable 4mm banana maleto 2mm socket, length 2m (for Stimulation electrodes)<strong>transducers</strong>CardiovascularHarvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.comJ15