PANELS Optical Acoustic Panels OPTICAL-ACOUSTIC INDICATORS TM24 cod. FH2600121 • Optical/acoustic signalling single face panel • Power supply : 12 – 24 Vdc • Max consumption: 100 mA • Lighting by high efficiency leds • Buzzer sound pressure: 85dB at 1m • Steady/flashing light, selectable • Continuous/intermittent sound, selectable • Protection against polarity reverse • Working temperature: -10°C ÷ + 50°C • Material: self-extinguishing ABS, class V0 • Protection: IP 40 • The following pictographs are available as standard: Fire alarm, Withdraw from premises, Extinguishing in progress, Gas alarm, Fire alarm. TB24 cod. FH2700121 Optical/acoustic signalling double face panel • Power supply : 12 – 24 Vdc • Max consumption: 100 mA • Lighting by high efficiency leds • Buzzer sound pressure: 85dB at 1m • Steady/flashing light, selectable • Continuous/intermittent sound, selectable • Protection against polarity reverse • Working temperature: -10°C ÷ + 50°C • Material: self-extinguishing ABS, class V0 • Protection: IP 40 • The following pictographs are available as standard: Fire alarm, Withdraw from premises, Extinguishing in progress, Gas alarm, Fire alarm. SPTB cod. SF5000121 Bracket for optical/acoustic signalling double face panel TB24 TM220 cod. FH2800121 230Vac self-powered optical/acoustic signalling single face panel • Power supply : 230Vac • Max consumption: 100 mA • Lighting by high efficiency leds • Buzzer sound pressure: 85dB at 1m • Steady/flashing light, selectable • Continuous/intermittent sound, selectable • Protection against polarity reverse • Buffer battery: 3.6 V 1.5Ah Ni-Cd • Alarm endurance: 1 hour • Working temperature: -10°C ÷ + 50°C • Material: self-extinguishing ABS, class V0 • Protection: IP 40 • The following pictographs are available as standard: Fire alarm, Withdraw from premises, Extinguishing in progress, Gas alarm, Fire alarm. 64 TM24 TB24 TM220
PANELS Optical Acoustic Panels OPTICAL-ACOUSTIC INDICATORS TM224 cod. FH3100121 24Vdc self-powered optical/acoustic signalling double face panel • Power supply : 24Vdc • Max consumption: 100 mA • Lighting by high efficiency leds • Buzzer sound pressure: 85dB at 1m • Steady/flashing light, selectable • Continuous/intermittent sound, selectable • Protection against polarity reverse • Buffer battery: 3.6 V 1.5Ah Ni-Cd • Alarm endurance: 1 hour • Working temperature: -10°C ÷ + 50°C • Material: self-extinguishing ABS, class V0 • Protection: IP 40 • The following pictographs are available as standard: Fire alarm, Withdraw from premises, Extinguishing in progress, Gas alarm, Fire alarm. TMSV cod. FH5400121 Single-face optical/sound plate with speech synthesizer • Power supply: 24Vdc • Absorption: 180 mA • 8 pre-recorded messages • 3 voice alarm zones • free combination of pre-recorded messages • 1 customized message • 4 operating modes: SPEECH - SOUND - SOUND + SPEECH - SPEECH + SOUND • Dimensions (L) x (H) x (D) mm: 365 x 180 x 50 TM224 TMSV 65
- Page 13 and 14: Control Unit C/302 CONVENTIONAL FIR
- Page 15 and 16: CONVENTIONAL FIRE DETECTION SYSTEMS
- Page 17 and 18: CONVENTIONAL FIRE DETECTION SYSTEMS
- Page 19 and 20: CONVENTIONAL DETECTORS METHANE gas
- Page 21 and 22: ADDRESSED FIRE DETECTION SYSTEMS AR
- Page 23 and 24: AREA54/1L Control Unit AREA54/1L co
- Page 25 and 26: AREA54/8L Control Units ADDRESSED F
- Page 27 and 28: Line Module MR/128 cod. SC2810121 A
- Page 29 and 30: Modules ADDRESSED FIRE DETECTION SY
- Page 31 and 32: Optical Detector BPA/212 cod. SD360
- Page 33 and 34: Buttons ADDRESSED FIRE DETECTION SY
- Page 35 and 36: UNIVERSAL CONNECTION BASES DUCTED D
- Page 37 and 38: FAP500 DIGITAL SYSTEM FAP 54/1 ....
- Page 39 and 40: FAP500 SYSTEM FAP500 DIGITAL SYSTEM
- Page 41 and 42: FAP544 Control Unit FAP544 cod. SC6
- Page 43 and 44: FAP500 SYSTEM: MODULES AND ACCESSOR
- Page 45 and 46: Thermo-speedometric detector FDTD50
- Page 47 and 48: EXTINGUISHING CONTROL UNIT 47
- Page 49: CDS CONTROL UNIT EXTINGUISHING CONT
- Page 52 and 53: Gas Detection Control Units DETECTO
- Page 54 and 55: GAS DETECTORS, EX II 3GD TYPE S2096
- Page 56 and 57: TOXIC AND EXPLOSIVES GAS DETECTORS
- Page 58 and 59: Heat detector RTS/4 cod. SD4C00123
- Page 60 and 61: LINEAR DETECTORS Fire and smoke lin
- Page 62 and 63: ASPIRATING SYSTEMS DETECTORS AND CO
- Page 66 and 67: VISUAL REPEATERS Outdoor visual rep
- Page 68 and 69: SOUNDERS OPTICAL-ACOUSTIC INDICATOR
- Page 70: POWER SUPPLY UNITS AND BATTERIES PO
PANELS<br />
Optical Acoustic Panels<br />
OPTICAL-ACOUSTIC INDICATORS<br />
TM24 cod. FH2600121<br />
• Optical/acoustic signalling single face panel<br />
• Power supply : 12 – 24 Vdc<br />
• Max consumption: 100 mA<br />
• Lighting by high efficiency leds<br />
• Buzzer sound pressure: 85dB at 1m<br />
• Steady/flashing light, selectable<br />
• Continuous/intermittent sound, selectable<br />
• Protection against polarity reverse<br />
• Working temperature: -10°C ÷ + 50°C<br />
• Material: self-extinguishing ABS, class V0<br />
• Protection: IP 40<br />
• The following pictographs are available as standard: Fire alarm, Withdraw<br />
from premises, Extinguishing in progress, Gas alarm, Fire alarm.<br />
TB24 cod. FH2700121<br />
Optical/acoustic signalling double face panel<br />
• Power supply : 12 – 24 Vdc<br />
• Max consumption: 100 mA<br />
• Lighting by high efficiency leds<br />
• Buzzer sound pressure: 85dB at 1m<br />
• Steady/flashing light, selectable<br />
• Continuous/intermittent sound, selectable<br />
• Protection against polarity reverse<br />
• Working temperature: -10°C ÷ + 50°C<br />
• Material: self-extinguishing ABS, class V0<br />
• Protection: IP 40<br />
• The following pictographs are available as standard: Fire alarm, Withdraw<br />
from premises, Extinguishing in progress, Gas alarm, Fire alarm.<br />
SPTB cod. SF5000121<br />
Bracket for optical/acoustic signalling double face panel TB24<br />
TM220 cod. FH2800121<br />
230Vac self-powered optical/acoustic signalling single face panel<br />
• Power supply : 230Vac<br />
• Max consumption: 100 mA<br />
• Lighting by high efficiency leds<br />
• Buzzer sound pressure: 85dB at 1m<br />
• Steady/flashing light, selectable<br />
• Continuous/intermittent sound, selectable<br />
• Protection against polarity reverse<br />
• Buffer battery: 3.6 V 1.5Ah Ni-Cd<br />
• Alarm endurance: 1 hour<br />
• Working temperature: -10°C ÷ + 50°C<br />
• Material: self-extinguishing ABS, class V0<br />
• Protection: IP 40<br />
• The following pictographs are available as standard: Fire alarm, Withdraw<br />
from premises, Extinguishing in progress, Gas alarm, Fire alarm.<br />
64<br />
TM24<br />
TB24<br />
TM220