FIRE DETECTION - Urmet
FIRE DETECTION - Urmet FIRE DETECTION - Urmet
Modules ADDRESSED FIRE DETECTION SYSTEMS ACCESSORIES FOR ADDRESSED SYSTEMS ISO/C cod. SC2210121 Short-circuit analyser module for lines for analogue detections; the module is designed to ensure the operation of the detectors and/or pushbuttons that are connected to the same line, in case a short-circuit occurs. • Yellow leds having the task of signalling the section where the short-circuit is being detected. • The module is contained in S/215 connector block. • The module needs no additional power supply. • Working voltage: 18Vdc modulated • Average absorption: 250 µA • Operation temperature: -20 to + 50°C • Relative humidity: 95 % Max RH non condensing • Dimensions: Ø 100 mm H 45 mm ISO/BASE-IP cod. SC6G00121 Same as ISO/C but in IP55 version. • Dimensioni (hxlxp): 90x130x58 mm. ISO ZB cod. SC4200121 Short-circuit analyser module for lines for analogue detections; the module is designed to ensure the operation of the detectors and/or pushbuttons that are connected to the same line, in case a short-circuit occurs. • The module is contained in a ZB200 base • The module needs no additional power supply. • Working voltage: 18Vdc modulated • Average absorption: 250 µA • Operation temperature: -20 to + 50°C • Relative humidity: 95 % Max RH non condensing • Dimensions: Ø 100 mm H 45 mm ISO/MINI cod. SC4000121 Short-circuit analyser module for lines for analogue detections; the module is designed to ensure the operation of the detectors and/or pushbuttons that are connected to the same line, in case a short-circuit occurs. • The module is contained in S/215 connector block. • The module needs no additional power supply. • Working voltage: 18Vdc modulated • Average absorption: 250 µA • Operation temperature: -20 to + 50°C • Relative humidity: 95 % Max RH non condensing • Dimensions: Ø 100 mm H 45 mm 30 ISO/C ISO/BASE-IP
Optical Detector BPA/212 cod. SD3600121 Low profile smoke optical addressed analogue detector. • Visual operation signal is provided by two red leds placed on the cap, which flashes at each call from the central unit. • The alarm signal from the central unit puts leds on steady. • Operation principle: Tyndall effect • Supply voltage: 18 Vdc modulated • Absorption: 280 µA at rest • Alarm repetition: O.C. 100 mA max • Visual alarm repetition: 2 red leds • Dimensions: Ø 100 x H 45 mm • Magnetic test • Operation temperature: –20 to +55 °C • Relative humidity: 95% max non condensing • EN 54 part 7 certified • Associable to following bases: ZB/200, ZB/201, ZB/204 Optical heat detector ADDRESSED FIRE DETECTION SYSTEMS DETECTORS FOR ADDRESSED SYSTEMS BPA/212-T cod. SD5800121 Low profile optic heat addressed analogue detector with heat probe with intervention temperature. • Visual operation signal is provided by two red leds placed on the cap, which flashes at each call from the central unit. • The alarm signal from the central unit puts leds on steady. • Operation principle: Tyndall effect+heat probe • Supply voltage: 18 Vdc modulated • Absorption: 280 µA at rest • Alarm repetition: O.C. 100 mA max • Visual alarm repetition: 2 red leds • Dimensions: Ø 100 x H 45 mm • Magnetic test • Operation temperature: –20 to +55 °C • Relative humidity: 95% max non condensing • Protection degree: IP 43 • Associable to following bases: ZB/200, ZB/201, ZB/204 BPA/212 BPA/212T 31
- Page 1: FIRE DETECTION ELKRON. THE HI-PROTE
- Page 4 and 5: 4 THE FIRE ELKRON OFFER CONVENTIONA
- Page 6 and 7: 6 THE FIRE ELKRON OFFER SPECIAL HEA
- Page 8 and 9: ALPHABETIC INDEX PRODUCT’S NAME C
- Page 11 and 12: CONVENTIONAL FIRE DETECTION SYSTEMS
- Page 13 and 14: Control Unit C/302 CONVENTIONAL FIR
- Page 15 and 16: CONVENTIONAL FIRE DETECTION SYSTEMS
- Page 17 and 18: CONVENTIONAL FIRE DETECTION SYSTEMS
- Page 19 and 20: CONVENTIONAL DETECTORS METHANE gas
- Page 21 and 22: ADDRESSED FIRE DETECTION SYSTEMS AR
- Page 23 and 24: AREA54/1L Control Unit AREA54/1L co
- Page 25 and 26: AREA54/8L Control Units ADDRESSED F
- Page 27 and 28: Line Module MR/128 cod. SC2810121 A
- Page 29: Modules ADDRESSED FIRE DETECTION SY
- Page 33 and 34: Buttons ADDRESSED FIRE DETECTION SY
- Page 35 and 36: UNIVERSAL CONNECTION BASES DUCTED D
- Page 37 and 38: FAP500 DIGITAL SYSTEM FAP 54/1 ....
- Page 39 and 40: FAP500 SYSTEM FAP500 DIGITAL SYSTEM
- Page 41 and 42: FAP544 Control Unit FAP544 cod. SC6
- Page 43 and 44: FAP500 SYSTEM: MODULES AND ACCESSOR
- Page 45 and 46: Thermo-speedometric detector FDTD50
- Page 47 and 48: EXTINGUISHING CONTROL UNIT 47
- Page 49: CDS CONTROL UNIT EXTINGUISHING CONT
- Page 52 and 53: Gas Detection Control Units DETECTO
- Page 54 and 55: GAS DETECTORS, EX II 3GD TYPE S2096
- Page 56 and 57: TOXIC AND EXPLOSIVES GAS DETECTORS
- Page 58 and 59: Heat detector RTS/4 cod. SD4C00123
- Page 60 and 61: LINEAR DETECTORS Fire and smoke lin
- Page 62 and 63: ASPIRATING SYSTEMS DETECTORS AND CO
- Page 64 and 65: PANELS Optical Acoustic Panels OPTI
- Page 66 and 67: VISUAL REPEATERS Outdoor visual rep
- Page 68 and 69: SOUNDERS OPTICAL-ACOUSTIC INDICATOR
- Page 70: POWER SUPPLY UNITS AND BATTERIES PO
Optical Detector<br />
BPA/212 cod. SD3600121<br />
Low profile smoke optical addressed analogue detector.<br />
• Visual operation signal is provided by two red leds placed on the cap, which<br />
flashes at each call from the central unit.<br />
• The alarm signal from the central unit puts leds on steady.<br />
• Operation principle: Tyndall effect<br />
• Supply voltage: 18 Vdc modulated<br />
• Absorption: 280 µA at rest<br />
• Alarm repetition: O.C. 100 mA max<br />
• Visual alarm repetition: 2 red leds<br />
• Dimensions: Ø 100 x H 45 mm<br />
• Magnetic test<br />
• Operation temperature: –20 to +55 °C<br />
• Relative humidity: 95% max non condensing<br />
• EN 54 part 7 certified<br />
• Associable to following bases: ZB/200, ZB/201, ZB/204<br />
Optical heat detector<br />
ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />
DETECTORS FOR ADDRESSED SYSTEMS<br />
BPA/212-T cod. SD5800121<br />
Low profile optic heat addressed analogue detector with heat probe with<br />
intervention temperature.<br />
• Visual operation signal is provided by two red leds placed on the cap, which<br />
flashes at each call from the central unit.<br />
• The alarm signal from the central unit puts leds on steady.<br />
• Operation principle: Tyndall effect+heat probe<br />
• Supply voltage: 18 Vdc modulated<br />
• Absorption: 280 µA at rest<br />
• Alarm repetition: O.C. 100 mA max<br />
• Visual alarm repetition: 2 red leds<br />
• Dimensions: Ø 100 x H 45 mm<br />
• Magnetic test<br />
• Operation temperature: –20 to +55 °C<br />
• Relative humidity: 95% max non condensing<br />
• Protection degree: IP 43<br />
• Associable to following bases: ZB/200, ZB/201, ZB/204<br />
BPA/212<br />
BPA/212T<br />
31