26.11.2012 Views

FIRE DETECTION - Urmet

FIRE DETECTION - Urmet

FIRE DETECTION - Urmet

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>FIRE</strong> <strong>DETECTION</strong><br />

ELKRON. THE HI-PROTECTION COMPANY


THE HI-PROTECTION COMPANY<br />

Another safe and secure day. Since 1974 Elkron has been committed to<br />

guarantee Security to any type of application, from small home systems<br />

to large installations. As a leading company in its sector and confirming<br />

its position with 14 Quality marks in many different countries, 21 International<br />

Patents registered, 1600 different products designed and developed,<br />

and 27 million products sold. Elkron has made a huge progress<br />

in research and innovation expressing new and unique solutions and<br />

gaining a steady international reputation in Security.<br />

As a fundamental achievement for its constant commitment to total<br />

quality, Elkron has always complied with the strictest international standards,<br />

generating a permanent<br />

process to check that such professional<br />

standards are constantly<br />

maintained as well as to ensure<br />

a continuous improvement of<br />

the products, respecting all the<br />

operating phases, from the initial<br />

product concept, to design,<br />

manufacturing, sales and distribution,<br />

and finally to customer<br />

support. Last but not the least,<br />

Elkron is a leading participator as<br />

coordinators and experts, in domestic<br />

(CEI) and European (CENE-<br />

LEC) standardisation projects.<br />

www.elkron.com<br />

3


4<br />

THE <strong>FIRE</strong> ELKRON OFFER<br />

CONVENTIONAL <strong>FIRE</strong> SYSTEMS<br />

C/302<br />

Single Zone central unit, with microprocessor<br />

in polycarbonate, suitable<br />

for controlling fire stop doors.<br />

C/7000<br />

Modular conventional fire detection<br />

central unit, with 16 bit microprocessor,<br />

4 detection zones expanda-<br />

ble up to 16.<br />

BUTTONS<br />

Alarm push-buttons with recommissoning,<br />

with glass breaking and unbreakable.<br />

C/54<br />

Compact central unit, with microprocessor,<br />

suitable for small size<br />

fire and gas systems. 4 detection<br />

lines 32 max detectors per zone.<br />

DETECTORS<br />

Optical smoke detectors, optical<br />

heat detectors, differential heat<br />

detectors, combustible gas detec-<br />

tors.<br />

ADDRESSED <strong>FIRE</strong> SYSTEMS<br />

AREA 54/1<br />

Analogue central unit, with 16 bit microprocessor,<br />

to manage fire systems with<br />

single detection line, where up to 128<br />

out of smoke detectors, gas detectors,<br />

heat detectors, pushbuttons actuators<br />

and interfaces to control external equip-<br />

ment can be connected.<br />

AREA 54/8<br />

Modular analogue central unit, with<br />

multiprocessor, having 8 LOOPs<br />

max. The unit is provided with 1<br />

MR/128 module (128 addresses).<br />

Expandable up to 1024 addresses<br />

by 7 additional line modules.<br />

DETECTORS<br />

Optical smoke detectors, optical<br />

heat detectors, differential heat detectors,<br />

UNIVERSAL BASES<br />

Universal connection bases with or<br />

without relay for conventional, digital<br />

and analogic detectors.<br />

PAGE<br />

36<br />

PAGE<br />

13<br />

PAGE<br />

16<br />

PAGE<br />

19<br />

PAGE<br />

23<br />

PAGE<br />

25<br />

PAGE<br />

31<br />

AREA 54/4<br />

Modular analogue central unit, with<br />

multiprocessor, having 4 LOOPs<br />

max. The unit is provided with base<br />

with 1 MR/128 module (128 addresses).<br />

Expandable up to 512<br />

addresses by 3 additional line mo-<br />

dules.<br />

AREA 54/16<br />

Modular analogue central unit, with<br />

multiprocessor, having 16 LOOPs max.<br />

The unit is provided with base with 1<br />

MR/128 module (128 addresses).<br />

Expandable up to 2048 addresses by<br />

15 additional line modules.<br />

BUTTONS<br />

Alarm push-buttons with recommissoning,<br />

with glass breaking and un-<br />

breakable.<br />

PAGE<br />

14<br />

PAGE<br />

17<br />

PAGE<br />

24<br />

PAGE<br />

26<br />

PAGE<br />

33<br />

DUCTED <strong>DETECTION</strong><br />

The analysis chamber for ducted<br />

detection was designed to check for<br />

the presence of smoke in air ducts<br />

and allows to timely detect a spre-<br />

ading fire.<br />

PAGE<br />

36


THE <strong>FIRE</strong> ELKRON OFFER<br />

FAP500 DIGITAL <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEM<br />

FAP541<br />

Microprocessor control unit with 1<br />

loop line. Possibility of managing up<br />

to 128 points for loop (64 for open<br />

line).<br />

FAP548<br />

Microprocessor control unit with<br />

1 loop line expandable up to 8.<br />

Possibility of managing up to 128<br />

points for loop (64 for open line).<br />

DETECTORS<br />

Optical smoke detectors, optical<br />

heat detectors, differential heat de-<br />

tectors, combustible gas<br />

detectors.<br />

<strong>FIRE</strong> EXSTINGUISHING<br />

CDS<br />

Fire extinguishing control unit with<br />

one channel expandable up to 2.<br />

PAGE<br />

48<br />

PAGE<br />

40<br />

PAGE<br />

41<br />

PAGE<br />

44<br />

FAP544<br />

Microprocessor control unit with<br />

1 loop line expandable up to 4.<br />

Possibility of managing up to 128<br />

points for loop (64 for open line).<br />

FAP5416<br />

Microprocessor control unit with<br />

1 loop line expandable up to 16.<br />

Possibility of managing up to 128<br />

points for loop (64 for open line).<br />

BUTTONS<br />

Alarm push-buttons with recommissoning,<br />

with glass breaking and un-<br />

breakable.<br />

GAS <strong>DETECTION</strong><br />

ATEX CONTROL UNITS<br />

ST/PL4<br />

Gas detection control<br />

unit allowing<br />

the connection of<br />

max 8 detectors.<br />

EXPLOSIVES AND TOXIC GAS DETECTORS<br />

TYPE EX II 3GD<br />

Petrol Vapour / Propane Gas /<br />

Butane Gas / Carbon Monoxide<br />

Methane Gas / GPL Gas<br />

FLAME DETECTORS<br />

RU-ADPE<br />

Flame detector immediately responding to infrared<br />

thermal radiation released by fire. The detector is tuned<br />

to flame pulses in order to ignore sunlight and<br />

lamps.<br />

PAGE<br />

56<br />

PAGE<br />

53<br />

PAGE<br />

52<br />

TYPE EX II 2GD<br />

Petrol Vapour / Propane Gas /<br />

Butane Gas / Carbon Monoxide<br />

Methane Gas / GPL Gas<br />

PAGE<br />

41<br />

PAGE<br />

41<br />

PAGE<br />

43<br />

ST/MTLSB<br />

Gas detection control<br />

unit allowing the<br />

connection of max<br />

108 detectors.<br />

LIQUID DETECTOR<br />

RA-209<br />

Electronic detector to detect the presence of (uninflammable)<br />

liquids. Detecting the presence of water<br />

is through 4 support gilt feet, which put the detector<br />

into alarm by switching a relay placed inside it.<br />

PAGE<br />

55<br />

PAGINA<br />

57<br />

5


6<br />

THE <strong>FIRE</strong> ELKRON OFFER<br />

SPECIAL HEAT DETECTOR<br />

RTS/2 - RTS/4 - RTS/6<br />

IP65 Special heat detector based on<br />

the deformation of a bimetallic element<br />

which closes a dry contact as the temperature<br />

is reached.<br />

S/2-100<br />

Linear detector suitable for all environments<br />

characterised in high ceilings,<br />

where using smoke optical detectors<br />

results to be particularly hard.<br />

PANELS<br />

PAGE<br />

57<br />

LINEAR DETECTORS<br />

PAGE<br />

59<br />

RLB/1 - RLB/2<br />

Thermosensitive linear detectors calibrated to 68°<br />

and 105° (certified).<br />

SF-100<br />

Fire and heat linear detector.<br />

The system includes three units: Transmitting<br />

unit (TX), Receiving unit (RX),<br />

co-ordination unit.<br />

OPTICAL-ACOUSTIC INDICATORS<br />

ELECTRONIC BELLS<br />

SOUNDERS<br />

Outdoor red self-powered<br />

siren made in<br />

die-cast aluminium.<br />

Optical/acoustic<br />

signalling single and<br />

double face panel.<br />

PAGE<br />

64<br />

Red siren for premises<br />

evacuation in compliance<br />

with with regulation<br />

626/94.<br />

VISUAL REPEATER<br />

PAGE<br />

68<br />

Visual repeater allowing to<br />

show the alarm status of a<br />

detector installed in hidden<br />

spaces.<br />

Bell with classic appearance for fire alarm<br />

systems and other warnings.<br />

PAGE<br />

59<br />

PAGE<br />

60<br />

PAGE<br />

66<br />

PAGE<br />

67<br />

ELECTROMAGNETS<br />

Electromagnetic stop implemented<br />

in order to keep open<br />

fire or transit doors and release<br />

them in case of fire.<br />

EXPLOSION PROOF SYSTEMS<br />

T/800<br />

The optical/acoustic system includes<br />

the body of siren T/800S<br />

and the body of visual repeater<br />

T/800L. These shells are made<br />

of a casting of cast iron G-20 uni<br />

5007.<br />

T/800S<br />

Siren made of a<br />

casting of cast<br />

iron G-20 uni<br />

5007 with a diffusing<br />

cone of<br />

plastic<br />

(ABS);<br />

material<br />

T/800L<br />

Visual repeater<br />

made up of a shell<br />

made of a casting<br />

of cast iron G-20<br />

uni 5007.<br />

PAGE<br />

68<br />

PAGE<br />

69


ALPHABETIC INDEX<br />

PRODUCT’S NAME CODE PAGE PRODUCT’S NAME CODE PAGE<br />

1370/15 MM7100123 68<br />

1370/30 MM7300123 68<br />

1469 SB4600123 20<br />

1471 SB5700123 20<br />

2470 SB4400121 20<br />

3465/24 HS1900123 67<br />

3470 SB4300123 20<br />

4460/24 HS1700123 67<br />

4476/24 HS7300123 67<br />

4479/24 HS7200123 67<br />

82425 SBG PS7900123 70<br />

82450 BG PS8000123 70<br />

AREA 54/16L SC3800121 26<br />

AREA54/1L SC3900121 23<br />

AREA54/4L SC1900121 24<br />

AREA54/8L SC4100121 25<br />

ASD SC2R00123 62<br />

AST AT7100123 62<br />

BP/212 SD3700121 17<br />

BP/212T SD8900121 18<br />

BPA/212 SD3600121 31<br />

BPA/212-T SD5800121 31<br />

BPG/213 CH4 SD3300121 19<br />

BPG/213 GPL SD1J00121 19<br />

BPT/214 SD3500121 18<br />

BTA/206 SD3400121 32<br />

C/54 SC1800121 14<br />

C/7000 SC5200121 16<br />

C/7000-R SC5300121 16<br />

C302 SC6000121 13<br />

CDS SC3600121 49<br />

CONSOLLE/54 KP3400121 32<br />

DBS SD9H10123 62<br />

DFS RT7100123 62<br />

DRS SD8H10123 62<br />

DSE/626 HS2100123 68<br />

DTS RT7200123 62<br />

EM100P MM9000123 68<br />

EM50P MM7000123 68<br />

ES50 SD8P00123 61<br />

ES80 SD9R00123 61<br />

ESPCDS SC3500121 49<br />

FA128 SC3310121 42<br />

FAP541 SC6100121 40<br />

FAP5416 SC6700121 41<br />

FAP544 SC6200121 41<br />

FAP548 SC6600121 41<br />

FDO500 SD4800121 44<br />

FDOT500 SD9K00121 45<br />

FDT500 SD5700121 44<br />

FDTD500 SD9000121 45<br />

<strong>FIRE</strong> TRACER SC4R00123 62<br />

FKP500 KP5200121 42<br />

FM500 SD6000121 43<br />

FMR500 SB6100121 43<br />

FOGLIO/54 SW2900121 34<br />

HP500F HS5000121 68<br />

INT8C/24V IL1010123 61<br />

INT-SONG/54 HS1010121 15<br />

IO500 SC3A00121 42<br />

IOM500 SC3B00121 42<br />

ISO ZB SC4200121 30<br />

ISO/BASE SC4H00121 29<br />

ISO/BASE-IP SC6G00121 30<br />

ISO/BP SC6H00121 29<br />

ISO/C SC2210121 30<br />

ISO/MINI SC4000121 30<br />

ITS500 IT1610121 43<br />

KATA IL7500123 61<br />

LAN/54 SC7910121 34<br />

LAN/TCP/IP500 IT1510121 43<br />

LR500 SR1100121 66<br />

LR500SI SR1200121 66<br />

MAPPA/54 SW2700121 34<br />

MAPPE/FAP500 SW3600121 43<br />

MAS/DIN-2000 SC2110121 28<br />

MAS/IP-2000 SC8710121 28<br />

MC/19 SC1C10121 27<br />

MCR/DIN-2000 SC9110121 29<br />

MCS/54 SC6810121 17<br />

MGSM500 CT6010121 43<br />

MI/410 SC2010121 28<br />

MI/410-S SC9610121 28<br />

ML7000 SC1A10121 17<br />

MMS/54 SC1B10121 34<br />

MOD/54-E SC2510121 15<br />

MOD/54-R SC2410121 15<br />

MODEM54 CT7300123 34<br />

MPSTN500 CT5910121 43<br />

MR/128 SC2810121 27<br />

MR7000 SC7810121 17<br />

MRS/232/485-DIN SC9310121 34<br />

MSP/54 SC2B10121 23<br />

P 445 SB3500121 20<br />

P/406 SB3000121 70<br />

P/406 SB4300123 20<br />

P/410 SB3600121 33<br />

P/420 SB2100121 33<br />

P/430 SB2200121 33<br />

P/435 SB3900121 33<br />

7


ALPHABETIC INDEX<br />

PRODUCT’S NAME CODE PAGE PRODUCT’S NAME CODE PAGE<br />

P 440 SB3800121 19<br />

PICO SC3R00123 62<br />

PUNTO/54 SW3100121 34<br />

R/820 SD3L10121 36<br />

RA/209 SD2B00121 57<br />

RA/209-S SD7L00121 57<br />

RB 1212 RB1110113 70<br />

RB 15 RB0810113 70<br />

RB 19 RB0310113 70<br />

RB 24 RB0510113 70<br />

RB 612 RB0910113 70<br />

RB06 RB0410113 70<br />

RB12 RB0210113 70<br />

RLB/1 SD6P00121 59<br />

RLB/2 SD5P00121 59<br />

RS232/485 IT1410121 42<br />

RTS/2 SD2C00123 57<br />

RTS/4 SD4C00123 58<br />

RTS/6 SD3C00123 58<br />

RU-ADPE SD7100121 56<br />

S/2-100 + INT8 C IL1500123 59<br />

S1604VB SD2T00123 53<br />

S1606CO SD7T00123 53<br />

S1702VB SD3T00123 54<br />

S1703CO SD8T00123 54<br />

S2096BU SD6T00123 53<br />

S2096GP SD4T00123 54<br />

S2096ME SD9S00123 54<br />

S2096PR SD5T00123 53<br />

S2097BU SD4U00123 55<br />

S2097GP SD2U00123 55<br />

S2097ME SD9T00123 55<br />

S2097PR SD3U00123 55<br />

S2097VB SD1U00123 55<br />

S2131CO SD5U00123 55<br />

ADM IL1110123 61<br />

SD500 SD4K00121 46<br />

SD500M SD4S00121 46<br />

SD500R SD5K00121 46<br />

SD500-RM SD6S00121 46<br />

SD515 SD2V00121 46<br />

SF-100 + INT8 C IL1400123 60<br />

SOFT/54 SW2300121<br />

SOFT/FAP500 SW3500121 43<br />

SONG/54 HS0910121 27<br />

SP/410 SC2610121 28<br />

SP/410-S SC4E10121 28<br />

SPTB SF5000121 64<br />

SSM SP7600123 61<br />

8<br />

ST/PL4 SC6R00123 52<br />

ST/PL4/ESP SC7R10123 52<br />

ST/S3REL SC5R10123 57<br />

STG/BOX ST0510123 53<br />

STG/IN8 SC9R10123 53<br />

STG/MTSLB SC8R00123 52<br />

STG/OUT16 SC1S10123 53<br />

T/800 FH3500121 69<br />

T/800L SR0200121 69<br />

T/800S HS1800121 69<br />

TB24 FH2700121 65<br />

TLG/54 SW2800121 34<br />

TM220 FH2800121 65<br />

TM224 FH3100121 65<br />

TM24 FH2600121 64<br />

TMSV FH5400121 65<br />

VAL TEST SI7100123 56<br />

WMB/138V15 ST0610123 53<br />

ZB/200 SD2700121 36<br />

ZB/201 SD2800121 36<br />

ZB/204 SD9D00121 36<br />

ZB/210 SD4300121 36<br />

ZB/212 SD1N00121 36<br />

ZB/215 ZC7100121 36


INDEX<br />

CONVENTIONAL<br />

<strong>FIRE</strong> <strong>DETECTION</strong><br />

SYSTEMS<br />

ADDRESSED<br />

<strong>FIRE</strong> <strong>DETECTION</strong><br />

SYSTEMS<br />

UNIVERSAL<br />

BASES<br />

DUCTED<br />

<strong>DETECTION</strong><br />

FAP 500<br />

DIGITAL<br />

SYSTEMS<br />

EXTINGUISHING<br />

CONTROL UNIT<br />

SPECIAL<br />

DETECTORS<br />

OPTICAL<br />

ACOUSTIC<br />

INDICATORS<br />

C/302 .............................13<br />

C/54 ...............................14<br />

C/7000 ...........................16<br />

DETECTORS ...................17<br />

BUTTONS .......................20<br />

AREA 54/1 .....................23<br />

AREA 54/4 .....................24<br />

AREA 54/8 .....................25<br />

AREA 54/16 ...................26<br />

DETECTORS ...................31<br />

CENTRALIZATION............34<br />

UNIVERSAL BASES .........36<br />

DUCTED <strong>DETECTION</strong> .......36<br />

FAP 541 .........................40<br />

FAP 544 .........................41<br />

FAP 548 .........................41<br />

FAP 5416 .......................41<br />

ACCESSORIES ................43<br />

DETECTORS ...................44<br />

EXTINGUISHING C.U. .......48<br />

GAS <strong>DETECTION</strong> C.U. ......52<br />

GAS DETECTORS ............53<br />

FLAME DETECTORS ........56<br />

SPECIAL HEAT DET .........57<br />

LINEAR DETECTORS .......59<br />

SUCTION SYSTEMS ........62<br />

PANEL ............................64<br />

OPTICAL REPEATER ........66<br />

BELLS ............................67<br />

SOUNDERS ....................68<br />

ELECTROMAGNETS .........68<br />

EXPLOSION PROOF . .......69


CONVENTIONAL<br />

<strong>FIRE</strong> <strong>DETECTION</strong><br />

SYSTEMS<br />

C/302 CONTROL UNIT ................ pag. 13<br />

C/54 CONTROL UNIT .................. pag. 14<br />

C/7000 CONTROL UNIT .............. pag. 16<br />

CONVENTIONAL DETECTORS ..... pag. 17<br />

CONVENTIONAL BUTTONS ......... pag. 20<br />

11


CONVENTIONAL <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

CONVENTIONAL SYSTEMS<br />

Conventional fire detection system by Elkron is proved to be the ideal system for all the systems<br />

which do not need a large extent to be available.<br />

Anyhow, central unit models, of which one is expandable up to 16 lines with 32 detectors, allow<br />

to implement systems fully covering any small to medium firm typology and are proved to be<br />

perfectly suitable for residential installations too.<br />

The system is completed by its wide range of smoke detectors, gas detectors, pushbuttons and<br />

relating signalling.<br />

12<br />

MCS/54<br />

Printer<br />

Module<br />

MR7000<br />

4 actuation<br />

relays<br />

module<br />

MOD/54-E<br />

Electrovalve<br />

Output<br />

Module<br />

MOD/54R<br />

Actuators<br />

module<br />

Bells/Panels<br />

Output<br />

Bells/Panels<br />

Output<br />

C/54 SYSTEM<br />

ML7000<br />

4 Zone<br />

Expansion<br />

1<br />

2<br />

3<br />

4<br />

1<br />

2<br />

3<br />

4<br />

1<br />

2<br />

3<br />

4<br />

C/7000 SYSTEM<br />

CONTROL UNIT ZONES (N.4)<br />

CONTROL UNIT ZONES<br />

EXPANSION MODULE (N.4)<br />

32 MAX<br />

points per<br />

zone<br />

32 MAX<br />

points<br />

per zone<br />

32 MAX<br />

points per<br />

zone


Control Unit C/302<br />

CONVENTIONAL <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

SINGLE ZONE CONTROL UNIT<br />

C/302 cod. SC6000121<br />

Single Zone central unit, with microprocessor in polycarbonate, suitable for<br />

controlling fire stop doors.<br />

• Internally provided with a smoke optical detector and a heat probe having 60°<br />

C intervention threshold.<br />

• The unit is capable to manage either up to 15 (optic or heat) conventional<br />

detectors or 2 gas detectors (BPG/213 model) on a conventional line set to<br />

single permission.<br />

• Output for electromagnets; the output is capable to support up to 6<br />

electromagnets.<br />

• Supply voltage: 230 Vac 50 Hz<br />

• Output voltage: 24 Vdc<br />

• Max current: 300 mA<br />

• Smoke detector: Optical with Tyndall effect<br />

• Heat detector: Heat probe calibrated to 60° C<br />

• Visual alarm: 1 red led, 1 24 V 2W lamp<br />

• Sound alarm: Buzzer<br />

• Operation temperature: -10°C to +50°C<br />

• Alarm relay output: 1A @ 30 Vdc<br />

• Protection degree: IP 32<br />

• Dimensions (HxLxD): 71 x 283 x 113mm<br />

• Weight (not including batteries): 700 g<br />

C/302<br />

13


C/54 Control Unit<br />

CONVENTIONAL <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

FOUR ZONE CONTROL UNIT<br />

C/54 cod. SC1800121<br />

Compact central unit, with microprocessor, suitable for small size fire and<br />

gas systems.<br />

• Composed of a red plastic enclosure made in ABS for wall mounting.<br />

• Italian or English language front side.<br />

• The unit has four independent detection lines, with maximum capacity of 30<br />

devices per line. Each detection line corresponds to a single zone and can be<br />

set to either single or double permission.<br />

• The central unit is also equipped with a dry contact relay output for failure,<br />

a controlled line for bells and sirens and an output for electromagnets<br />

control.<br />

• The central unit is equipped with an electronic circuit to recharge and control<br />

the batteries.<br />

• Leak towards the earth signalling on central unit panel.<br />

• Mechanical key to enable programming functions and/or commands<br />

(silencing, resetting, cutting off, etc.)<br />

• Facility for adding, into the central unit, an optional module allowing to have<br />

either 8 zone relay outputs or a module allowing to control a solenoid valve<br />

(MOD54E).<br />

• Number of zones: 4, independent<br />

• Max number of detectors per zone: 30 (Smoke, heat, pushbuttons)<br />

• In compliance with EN 54 parts 2 – 4<br />

• Supply voltage: 230 Vac 50 Hz<br />

• Output voltage: 23 Vdc – 27.6 Vdc<br />

• Max current: 500 mA<br />

• Assignable batteries: 2 x 12V – 7.5 Ah<br />

• Failure central repetition: 1 A 30Vdc relay<br />

• Controlled siren output<br />

• Output for electromagnets<br />

• Relative Humidity: 95 % Max RH non condensing<br />

• Operation temperature: -5° to +50° C<br />

• Protection degree: IP 32<br />

• Dimensions (HxLxD): 386 x 269 x 96 mm<br />

• Weight (not including batteries): 2,7 Kg<br />

• Accessories: control module for siren line (INT-SONG/54 or SONG/54)<br />

Control board for solenoid valve (MOD/54-E), Board with 4 relays for line<br />

alarms (MOD/54-R)<br />

14<br />

C/54


CONVENTIONAL <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

FOUR ZONE CONTROL UNIT<br />

Accessories for C/54 control unit<br />

MOD/54-R cod. SC2410121<br />

Module allowing C/54 central unit to increment and differentiate actuation<br />

control for each zone.<br />

• The module has 4 aggregated relays (NC or NO max. 1A - 30 VDC): Alarm<br />

1 - Alarm 2 - Exclusion - Mains failure.<br />

• Each Zone has:<br />

• One controlled output for plates, sirens or bells.<br />

• One output for either electromagnets or self-powered siren.<br />

• One exchange dry contact relay (Closed - Normally Closed - Normally Open<br />

max. 1 A - 30 VDC), that can be set on either Alarm 1 (Default) or Alarm 2<br />

events.<br />

• Max current which can be supplied by module: 500 mA<br />

MOD/54-E cod. SC2510121<br />

Module allowing C/54 central unit to have a dedicated output for controlling<br />

a solenoid valve by a programmable activation lag.<br />

• The module has 4 aggregated relays (NC or NO max. 1A - 30 VDC): Alarm<br />

1 - Alarm 2 - Exclusion - Mains failure.<br />

• The module also has following outputs:<br />

N° 1 line for manually resetting solenoid electrovalve<br />

N° 1 output line for the optical/acoustic signalling that cannot be silenced.<br />

• Max current which can be supplied by module: 500 mA<br />

SONG/54 cod. HS0910121<br />

Module to check and actuate bells/plates/sirens.<br />

• It is to be used on controlled outputs in central units.<br />

• The module is to be installed immediately near the device to be checked.<br />

• Dimensions (HxL): 25x30 mm<br />

INT-SONG/54 cod. HS1010121<br />

Intermediate module to check and actuate bells/plates/sirens.<br />

• It is to be used on controlled outputs in central units.<br />

• The module is to be installed immediately near the device to be checked.<br />

• Dimensions (HxL): 25x30 mm<br />

MOD/54-R<br />

MOD/54-E<br />

SONG/54<br />

INT-SONG/54<br />

15


C/7000<br />

CONVENTIONAL <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

MODULAR CONTROL UNIT 4 UP TO 16 ZONES<br />

C/7000 cod. SC5200121<br />

Modular conventional fire detection central unit, with 16 bit microprocessor,<br />

4 detection zones expandable up to 16.<br />

• Software in 2 languages (Italian and English), which can be selected by user.<br />

• Facility for connecting up to 32 devices per zone.<br />

• Facility for associating a 16-character text per zone / zone group.<br />

• Backlit alphanumeric display with 4 lines by 20 characters.<br />

• 6 programmable access passwords.<br />

• Relay actuation control independent of the zones.<br />

• Central unit walk test with programmable self-resetting time.<br />

• Evacuation function (Master Alarm) which can be either actuated from<br />

keyboard or associated to a single zone.<br />

• Chronological history log with 50 events.<br />

• Programmable central unit alarm timing.<br />

• Auxiliary input which can be set by resetting, acquisition or Master Alarm.<br />

• Number of zones: 4, independent, expandable to 16<br />

• Max number of detectors per zone: 32 (Smoke detectors, heat detectors,<br />

pushbuttons)<br />

• Backlit LCD display with 4 lines by 20 characters.<br />

• 6 programmable access passwords<br />

• In compliance with EN 54 parts 2 – 4<br />

• Chronological history log with 50 events.<br />

• Supply voltage: 230 Vac 50 Hz<br />

• Output voltage: 27.6 Vdc<br />

• Max Current: 500mA<br />

• Assignable batteries: 2 x 12V – 7.5 Ah<br />

• Signalling outputs: 2 Alarm relays of 3 A 30Vdc prog. for Alarms 1 2 3<br />

1 Failure relay of 3 A 30Vdc (Closed /NO or Closed/NC)<br />

1 Programmable relay of 3 A 30Vdc (C/NO or C/NC)<br />

• Controlled siren outputs<br />

• Operation temperature: -5° to +50° C<br />

• Relative humidity: 93 % non condensing<br />

• Protection: IP 31<br />

• Dimensions (HxLxD): 454x377x132 mm<br />

• Weight (not including batteries): 9 Kg<br />

C/7000-R cod. SC5300121<br />

• Same characteristics of C/7000 but with 4 relays freely programmable<br />

on board<br />

16<br />

C/7000


CONVENTIONAL <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

MODULAR CONTROL UNIT 4 UP TO 16 ZONES<br />

Accessories for C/7000 control unit<br />

SONG/54 cod. HS0910121<br />

Control module for siren line.<br />

INT-SONG/54 cod. HS1010121<br />

Intermediate control module for siren line.<br />

ML7000 cod. SC1A10121<br />

Expansion module for 4 lines.<br />

MR7000 cod. SC7810121<br />

Expansion module for 4 relays.<br />

MCS/54 cod. SC6810121<br />

Module for connecting a printer.<br />

CONVENTIONAL DETECTORS<br />

Optical Smoke Detector<br />

BP/212 cod. SD3700121<br />

Low profile conventional optical smoke detector.<br />

• Correct operation signalling is from a flashing green led placed on the cap.<br />

• Alarm signalling is from a red led placed on the cap.<br />

• On the detector there are two open collector outputs, one for correct<br />

operation signalling, the other for alarm signalling.<br />

• A detector characteristic feature is its intervention threshold self-adjusting<br />

capability on its being put on.<br />

• Correct operation green led<br />

• Alarm red led<br />

• Alarm output: 100 mA (O.C.)<br />

• Operation principle: Tyndall effect<br />

• Supply voltage: 11 – 30 Vdc<br />

• Alarm repetition: O.C. 100 mA max<br />

• Operation repetition: O.C. 10 mA max<br />

• Absorption: 100 µA 18 Vdc at rest , 22 mA 18 Vdc on alarm status<br />

• Magnetic test<br />

• Operation temperature: da –20 a +50 °C<br />

• Relative humidity: 95% max non condensing<br />

• EN 54 part 7 certified.<br />

• Associable to following bases: ZB/200, ZB/201, ZB/204<br />

• Dimensions (HxLxD): Ø 100 x H 45 mm<br />

ML7000<br />

MR7000<br />

MCS/54<br />

BP/212<br />

17


CONVENTIONAL DETECTORS<br />

Optical heat detector<br />

BP/212 T cod. SD8900121<br />

Low profile conventional optic heat detector with heat probe having 70° C<br />

intervention temperature.<br />

• Correct operation signalling is from a flashing green led placed on the cap.<br />

• Alarm signalling is from a red led placed on the cap.<br />

• On the detector there are two open collector outputs, one for correct<br />

operation signalling, the other for alarm signalling.<br />

• Correct operation green led<br />

• Alarm red led<br />

• Alarm output: 100 mA (O.C.)<br />

• Operation principle: Tyndall effect<br />

• Supply voltage: 11 – 30 Vdc<br />

• Alarm repetition: O.C. 100 mA max<br />

• Operation repetition: O.C. 10 mA max<br />

• Absorption: 100 µA 18 Vdc at rest 22 mA 18 Vdc on alarm status<br />

• Magnetic test<br />

• Operation temperature: da –20 a +50 °C<br />

• Relative humidity: 95% max non condensing<br />

• EN 54 part 7 certified.<br />

• Associable to following bases: ZB/200, ZB/201, ZB/204<br />

• Dimensions: Ø 100 x H 45 mm<br />

Differential heat detector<br />

BPT/214 cod. SD3500121<br />

Low profile conventional (thermo-speedometric) differential ratio of rise heat<br />

detector with 58°C maximum intervention temperature.<br />

• Correct operation signalling is from a flashing green led placed on the cap.<br />

• Alarm signalling is from a red led placed on the cap.<br />

• Correct operation green led<br />

• Alarm red led<br />

• Alarm output: 100 mA (O.C.)<br />

• Operation principle: pair of heat probes<br />

• Supply voltage: 11 – 30 Vdc<br />

• Alarm repetition: O.C. 100 mA max<br />

• Absorption: 100 µA 18 Vdc at rest 22 mA 18 Vdc on alarm status<br />

• In compliance with EN 54 part 5<br />

• Magnetic test<br />

• Operation temperature: –20 a +50 °C<br />

• Relative humidity: 95% max non condensing<br />

• Associable to following bases: ZB/200, ZB/201, ZB/204<br />

• Dimensions: Ø 100 x H 45 mm<br />

18<br />

CONVENTIONAL <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

BP/212T<br />

BPT/214


CONVENTIONAL DETECTORS<br />

METHANE gas detector<br />

BPG/213 CH4 cod. SD3300121<br />

Methane gas detector with semiconductor (semiconductor head FIGARO) having<br />

2 intervention thresholds which can be calibrated and are independent.<br />

• Both alarm thresholds are stored and transmit, to control central unit, two<br />

quite differentiated signals allowing to operate by steps on actuations on field.<br />

• Operation voltage: 12 – 30 Vdc<br />

• Average absorption with fixed supply: 45 mA a 27 Vdc<br />

• Pre-alarm absorption: 20 mA a 18 Vdc<br />

• Alarm absorption: 40 mA a 18 Vdc<br />

• Alarm signal repetition: 100 mA (O.C.)<br />

• Pre-alarm visual repetition: yellow led<br />

• Visual alarm repetition: red led<br />

• Relative humidity: 95% max non condensing<br />

• Adjustable alarm threshold: 5% to 100% E.L.L.<br />

• Detectable gasses: methane<br />

• Dimensions: Ø 100 x H 45 mm<br />

GPL gas detector<br />

BPG/213 GPL cod. SD1J00121<br />

GPL gas detector with semiconductor (semiconductor head FIGARO) having 2<br />

intervention thresholds which can be calibrated and are independent.<br />

• Both alarm thresholds are stored and transmit, to control central unit, two<br />

quite differentiated signals allowing to operate by steps on actuations on field.<br />

• Operation voltage: 12 – 30 Vdc<br />

• Average absorption with fixed supply: 45 mA a 27 Vdc<br />

• Pre-alarm absorption: 20 mA a 18 Vdc<br />

• Alarm absorption: 40 mA a 18 Vdc<br />

• Alarm signal repetition: 100 mA (O.C.)<br />

• Pre-alarm visual repetition: yellow led<br />

• Visual alarm repetition: red led<br />

• Relative humidity: 95% max non condensing<br />

• Adjustable alarm threshold: 5% to 100% E.L.L.<br />

• Detectable gasses: GPL<br />

• Dimensions: Ø 100 x H 45 mm<br />

Buttons<br />

CONVENTIONAL <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

CONVENTIONAL PUSH BUTTONS<br />

P440 cod. SB3800121<br />

Red alarm conventional pushbutton with recommissioning.<br />

• Visual alarm repetition: red led<br />

• Weight: 100 g<br />

• Alarm absorption: 20 mA @ 18 Vdc<br />

• Actuation Type: Recommissioning<br />

• Dimensions (HxLxD): 110 x 110 x 42 mm<br />

BPG/213 CH4<br />

BPG/213 GPL<br />

P440<br />

19


CONVENTIONAL PUSH BUTTONS<br />

Buttons<br />

P445 cod. SB3500121<br />

Red alarm conventional pushbutton with breaking.<br />

• Visual alarm repetition: red led<br />

• Alarm absorption: 20 mA @ 18 Vdc<br />

• Actuation Type: Breaking<br />

• EN54 part 1<br />

• Weight: 100 g<br />

• Dimensions (HxLxD): 110 x 110 x 42 mm<br />

1469 cod. SB4600123<br />

Break glass outdoor red alarm conventional pushbutton made in die-cast<br />

aluminium.<br />

• Alarm absorption: 20 mA @ 18 Vdc<br />

• Actuation Type: Breaking<br />

• Protection degree: IP 65<br />

• Alarm resistance: 820 ohm 2W<br />

• Weight: 400 g<br />

• Dimensions (HxLxD): 95x95x 42 mm<br />

2470 cod. SB4400121<br />

Break glass red alarm conventional pushbutton with transparent protection<br />

cover.<br />

• Visual alarm repetition: red led<br />

• Weight: 180 g<br />

• Alarm absorption: 20 mA @ 18 Vdc<br />

• Actuation Type: Breaking<br />

• Protection degree: IP 54<br />

• Alarm resistance: 820 ohm 2W<br />

• Dimensions (HxLxD): 85x85x52 mm<br />

3470 cod. SB4300123<br />

Break glass red alarm conventional pushbutton.<br />

• Visual alarm repetition: red led<br />

• Weight: 120 g<br />

• Alarm absorption: 20 mA @ 18 Vdc<br />

• Actuation Type: Breaking<br />

• Protection degree: IP 30<br />

• Alarm resistance: 820 ohm 2W<br />

• Dimensions (HxLxD): 84 x 120 x 31 mm<br />

P/406 cod. SB3000121<br />

Pushbutton for fire manual signalling, with explosion proof shell, for areas<br />

with a potentially explosive atmosphere.<br />

• Hammer for glass breaking provided. Pushbutton made of diecast material,<br />

red colour epoxy painting.<br />

• Cable entry holes: 2x3/4 gas<br />

• Classified: II 2GD EEx d IIB T6, EEx d IIB + H2 T6<br />

• Certified: CESI 03 ATEX 050<br />

• Operation temperature: -20 C° to + 50 C°<br />

• Weight: 1.1 kg<br />

1471 cod. SB5700123<br />

Hammer<br />

20<br />

CONVENTIONAL <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

P445<br />

1469<br />

2470<br />

3470<br />

P/406


ADDRESSED<br />

<strong>FIRE</strong> <strong>DETECTION</strong><br />

SYSTEMS<br />

AREA 54/1 ................................ pag. 23<br />

AREA 54/4 ................................ pag. 24<br />

AREA 54/8 ................................ pag. 25<br />

AREA 54/16 .............................. pag. 26<br />

ACCESSORIES ........................... pag. 27<br />

DETECTORS .............................. pag. 31<br />

BUTTONS .................................. pag. 33<br />

CENTRALIZATION....................... pag. 34<br />

21


ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

ADDRESSED SYSTEMS<br />

A technological innovation from Elkron-Sira proposes a last generation multiprocessor fire analogue<br />

detection system. It is a system for all applications, even the widest ones, and for all environmental<br />

typologies. AREA54 series is provided with central units from 1 loop, for 128 addresses,<br />

up to 32 loops, for 4,096 addresses. The system can be fully managed and programmed either<br />

directly from local keyboard or smoothly by PC, via dedicated software (SOFT/54).<br />

22<br />

REMOTE<br />

PANELS<br />

RS485<br />

RS232<br />

PROGRAMMING<br />

SOFTWARE<br />

MAPPING<br />

SOFTWARE<br />

LOOP LINE<br />

128 MAX<br />

DEVICES<br />

AREA54/4<br />

MR/128<br />

SP/410 LINEAR<br />

DETECTOR<br />

MI/410<br />

MAS/DIN-2000 PANEL<br />

BTA/206<br />

+ ZB200<br />

BPA/212<br />

+ ZB200<br />

BPA/212<br />

+ ZB200<br />

P430<br />

LR500<br />

LR500<br />

EXTERNAL<br />

POWER<br />

SUPPLY<br />

UNITS


AREA54/1L Control Unit<br />

AREA54/1L cod. SC3900121<br />

Analogue central unit, with 16 bit microprocessor, to manage fire systems<br />

with single detection line.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

128 ADDRESSES CONTROL UNITS<br />

It is possibile to connect up to 128 out of smoke detectors, gas detectors,<br />

heat detectors, pushbuttons actuators and interfaces to control external<br />

equipment can be connected.<br />

Detection line can be programmed in following configurations:<br />

4 open lines (max 32 devices per line)<br />

1 loop line (max 128 devices)<br />

2 loop lines (max 64 devices per line).<br />

1 RS232 output towards PC<br />

LCD display with 8 lines by 40 characters<br />

Event log: 1000 events<br />

Signalling outputs:<br />

Alarm Relay 1 or 3 (1A@30 Vdc), NO/NC contact<br />

Alarm Relay 2 (5A@30 Vdc)<br />

Failure or exclusion Relay (5A @ 30 Vdc) NO/NC contact<br />

Network in Relay (1A @ 30 Vdc) NO/NC contact<br />

Controlled siren output for optical/acoustic indicators<br />

Controlled output for self-powered sirens<br />

In compliance with EN54/2-4<br />

Input voltage: 230 Vdc 50 Hz<br />

Ouput voltage: 27 Vdc 500 mA<br />

Battery management, check and charge: 700 mA<br />

Assignable batteries: max 2 x 12V – 15 Ah<br />

Operation temperature: -5 to + 50°C<br />

Base made in metal sheet and front side made in ABS.<br />

Dimensions (HxLxD): 450 x 350 x 160 mm.<br />

Accessories for AREA54/1L control unit<br />

MSP/54 cod. SC2B10121<br />

Module allowing Console 54, printer and a PC workstation to be connected<br />

to AREA54/1 central unit.<br />

• CENTRONICS opto-isolated port for connecting a printer<br />

• RS 232 opto-isolated output for connection to a personal computer<br />

• 485 opto-isolated output for connecting remote panels<br />

• Dimensions (HxL): 160x65<br />

AREA54/1L<br />

MSP/54<br />

23


AREA54/4L Control Unit<br />

ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

4 LOOP CONTROL UNIT<br />

AREA 54/4L cod. SC1900121<br />

Modular analogue central unit, with multiprocessor, having 4 LOOPs max.<br />

• The unit is provided with base with 1 MR/128 module (128 addresses).<br />

• Expandable up to 512 addresses by 3 additional line modules.<br />

• By a two-lead closed or open loop detection line, up to 128 out of smoke<br />

detectors, gas detectors, heat detectors, pushbuttons, actuators and<br />

interfaces to control external equipment can be connected to each module.<br />

• 1 RS232 opto-isolated bi-directional output towards PC.<br />

• 1 RS485 opto-isolated serial output for communication from and to remote<br />

keyboard.<br />

• LCD display with 8 lines by 40 characters.<br />

• Programming from keyboard and PC.<br />

• 120 software zones.<br />

• 60 device groups.<br />

• 60 zone assemblies.<br />

• Event log: 1000 events.<br />

• Signalling outputs:<br />

Alarm 1, Alarm 2, Alarm 3 relays<br />

Failure relay<br />

Exclusion relay<br />

Network in relay<br />

• Controlled output for self-powered external siren.<br />

• Controlled output for self-powered external siren.<br />

• Controlled siren output for optical/acoustic indicators.<br />

• In compliance with EN54/2-4.<br />

• Input voltage: 230 Vdc 50 Hz.<br />

• Ouput voltage: 27 Vdc max 1.5A.<br />

• Battery management, check and charge: 700 mA.<br />

• Casing: steel painted with epoxy powders.<br />

• Assignable batteries: max 2 x 12V – 15 Ah.<br />

• Operation temperature: -5 to + 50°C.<br />

• Available also in Rack 19” version.<br />

• LCD display with 16 lines by 40 characters.<br />

• Dimensions (HxLxD): 400 x 480 x 136 mm.<br />

24<br />

AREA 54/4L


AREA54/8L Control Units<br />

ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

EXPANDABLE CONTROL UNITS (UP TO 1024 ADDR.)<br />

AREA54/8L cod. SC4100121<br />

Modular analogue central unit, with multiprocessor, having 8 LOOPs max.<br />

• The unit is provided with 1 MR/128 module (128 addresses).<br />

• Expandable up to 1024 addresses by 7 additional line modules.<br />

• By a two-lead closed or open loop detection line, up to 128 out of smoke<br />

detectors, heat detectors, gas detectors, pushbuttons, actuators and<br />

interfaces to control external equipment can be connected to each module.<br />

• 1 RS232 opto-isolated bi-directional output towards PC.<br />

• 1 RS485 opto-isolated serial output for communication from and to remote<br />

keyboard.<br />

• LCD display with 16 lines by 40 characters<br />

• Programming from keyboard and PC.<br />

• 240 software zones.<br />

• 120 device groups.<br />

• 120 zone groups<br />

• Event log: 1000 events<br />

• Signalling outputs:<br />

Alarm 1 relay, Alarm 2, Alarm 3<br />

Failure relay<br />

Exclusion relay<br />

Network in relay<br />

• Controlled output for self-powered external siren.<br />

• Controlled siren output for optical/acoustic indicators.<br />

• In compliance with EN54 part 4 N°1293 - CPD - 0040 and EN 54 part 2<br />

• Input voltage: 230 Vdc 50 Hz<br />

• Ouput voltage: 27 Vdc max 1.5A<br />

• Battery management, check and charge: 700 mA<br />

• Casing: steel painted with epoxy powders<br />

• Dimensions (hxlxd): 500x482x145 mm<br />

• Assignable batteries: max 2 x 12V – 15 Ah<br />

• Operation temperature: -5 to + 50°C<br />

• Available also in Rack 19” version<br />

• LCD display with 16 lines by 40 characters<br />

• 1 MC/19 module for an independent repetition of the alarm, failure and<br />

exclusion status of each line<br />

AREA 54/8L<br />

25


AREA54/16L Control Unit<br />

ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

EXPANDABLE CONTROL UNITS (UP TO 1024 ADDR.)<br />

AREA54/16L cod. SC3800121<br />

Modular analogue central unit, with multiprocessor, having 16 LOOPs max.<br />

The unit is provided with base with 1 MR/128 module (128 addresses).<br />

• Expandable up to 2048 addresses by 15 additional line modules.<br />

• By a two-lead closed or open loop detection line, up to 128 out of smoke<br />

detectors, gas detectors, heat detectors, pushbuttons, actuators and<br />

interfaces to control external equipment can be connected to each module.<br />

• 1 RS232 opto-isolated bi-directional output towards PC.<br />

• 1 RS485 opto-isolated serial output for communication from and to remote<br />

keyboard.<br />

• LCD display with 16 lines by 40 characters.<br />

• Programming from keyboard and PC.<br />

• 480 software zones.<br />

• 240 device groups.<br />

• 240 zone groups.<br />

• Event log: 1000 events<br />

• Signalling outputs:<br />

Alarm 1 relay, Alarm 2, Alarm 3<br />

Failure relay<br />

Exclusion relay<br />

Network in relay<br />

• Controlled output for self-powered external siren.<br />

• Controlled siren output for optical/acoustic indicators.<br />

• In compliance with EN54/2-4<br />

• Input voltage: 230 Vdc 50 Hz<br />

• Ouput voltage: 27 Vdc max 1.5A<br />

• Battery management, check and charge: 700 mA<br />

• Casing: steel painted with epoxy powders<br />

• Assignable batteries: max 2 x 12V – 15 Ah<br />

• Operation temperature: -5 to + 50°C<br />

• Available also in Rack 19” version<br />

• LCD display with 16 lines by 40 characters<br />

• 2 MC/19 module for an independent repetition of the alarm, failure and<br />

exclusion status of each line.<br />

• Dimensions (HxLxD): 770 x 482 x 155 mm<br />

26<br />

AREA 54/16L


Line Module<br />

MR/128 cod. SC2810121<br />

Addressable line module allowing to acquire, pilot and check a closed or open<br />

type detection line on which up to 128 addressed devices can be mounted.<br />

• Fully managed by microprocessor.<br />

• RS485 57600 bps serial asynchronous communication.<br />

• Autonomous operation in case of control unit failure.<br />

• Managed by microprocessor.<br />

• Module addressing 1 – 32.<br />

• Relay for release from RS485 in case of failure.<br />

• 27 Vdc supply.<br />

• Dimensions (hxl): 110 x 65 mm.<br />

Modules<br />

ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

ACCESSORIES FOR ADDRESSED SYSTEMS<br />

MSP/54 cod. SC2B10121<br />

Module allowing a parallel 80 column printer with continuous form to be<br />

connected.<br />

• Dimensions (hxl): 185 x 45 mm<br />

SONG/54 cod. HS0910121<br />

Module to check and activate bells/plates/sirens. It is to be used on controlled<br />

outputs in central units.<br />

• The module is to be installed immediately near the device to be checked.<br />

• Dimensions (hxl): 25 x 30 mm.<br />

INT-SONG/54 cod. HS1010121<br />

Module to check and activate bells/plates/sirens. It is to be used on controlled<br />

outputs in central units.<br />

• The module is to be installed immediately near the device to be checked.<br />

• Dimensions (hxl): 25 x 30 mm.<br />

MC/19 cod. SC1C10121<br />

Independent display panel of the alarm, failure and exclusion status of each<br />

line.<br />

• The module only concerns AREA54 central units with 8 or 16 lines in Rack<br />

19” version.<br />

• Dimensions (hxlxp): 89 x 482 x 28 mm.<br />

MR/128<br />

MSP/54<br />

SONG/54<br />

INT-SONG/54<br />

MC/19<br />

27


Modules<br />

SP/410 cod. SC2610121<br />

Analogue addressed multi-purpose interface allowing to control dry contact<br />

equipment or input for impulsive contacts and to reset connected equipment,<br />

e.g. linear detectors, bathe tie rods or normally open pushbuttons, etc.<br />

• Working voltage: 18 Vdc modulated<br />

• Assorbimento medio: 150 µA.<br />

• Average absorption: 150 µA.<br />

• Operation temperature: -20° C to + 50° C.<br />

• Relative humidity: 95 % Max RH non condensing.<br />

• Dimensions (DIN guide) (HxLxD): 44 x 110 x 21 mm.<br />

SP/410-S cod. SC4E10121<br />

Same as SP/410 but in IP55 enclosure.<br />

• Dimensions (hxlxp): 105 x 170 x 82 mm.<br />

MI/410 cod. SC2010121<br />

Analogue addressed interface allowing to control equipment with dry and<br />

not impulsive contacts, e.g. pushbuttons, switches, technological contacts,<br />

heat sensing cables, by using proper connection.<br />

• Working voltage: 18 Vdc modulated.<br />

• Average absorption: 100 µA<br />

• Alarm repetition (O.C): 100 mA Max<br />

• Visual Alarm repetition: red led<br />

• Operation temperature: -20°C to + 50°C<br />

• Relative humidity: 95 % Max RH non condensing<br />

• Dimensions (HxLxD): 44 x 67 mm.<br />

MI/410-S cod. SC9610121<br />

Same as MI/410 but in IP55 version.<br />

• Dimensions (HxLxD): 90 x 130 x 58 mm.<br />

MAS/DIN-2000 cod. SC2110121<br />

Analogue addressed actuation module allowing to manage accessory devices<br />

arranged on field (plates, sirens, shutters, auxiliary relays, electromagnets,<br />

etc.).<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

ACCESSORIES FOR ADDRESSED SYSTEMS<br />

The module has 4 open collector electronic repetitions (100mA) which define<br />

fault, alarm 1, alarm 2, reset conditions and a repetition with the switching<br />

by a relay which can be preselected via a jumper in order that the module can<br />

operate in case of failure, alarm 1, alarm 2 or reset.<br />

Supply voltage: 20÷30Vdc<br />

Working voltage: 18 Vdc modulated<br />

Rest absorption: 200 mA<br />

Alarm absorption: 30 mA<br />

Alarm repetition (O.C): 100 mA max<br />

Relay output: 1A @ 24Vdc<br />

Operation temperature: -10 ÷ 50°C<br />

Dimensions (HxLxD): 65 x 110 x 35 mm.<br />

MAS/IP-2000 cod. SC8710121<br />

Same as MAS/DIN-2000 but in IP55 version.<br />

• Dimensions (HxLxD): 105 x 170 x 82 mm.<br />

28<br />

SP/410<br />

MI/410<br />

MAS/DIN-2000


Modules<br />

ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

ACCESSORIES FOR ADDRESSED SYSTEMS<br />

MCR/DIN-2000 cod. SC9110121<br />

Analogue addressed module with collective addressing. The module allows to<br />

manage a secondary line, made up of conventional detectors. Max number<br />

of elements is 10.<br />

• The interface has 4 O.C. repetitions and 4 relays for failure, alarm 1, alarm<br />

2 reset status.<br />

• Supply voltage: 20÷30Vdc<br />

• Working voltage: 18Vdc modulated<br />

• Rest absorption: 1 mA<br />

• Alarm absorption: 20 mA per alarmed relay<br />

• Repetition outputs (O.C.): 100 mA max<br />

• Relay output: 1A @ 24Vdc<br />

• Operation temperature: -10÷50°C<br />

• Dimensions (HxLxD): 112 x 168 x 50 mm.<br />

ISO/BP cod. SC6H00121<br />

Short-circuit analyser module for lines for analogue detections; the module<br />

is designed to ensure the operation of the detectors and/or pushbuttons<br />

that are connected to the same line, in case a short-circuit occurs.<br />

• The module is contained in smoke detector cap.<br />

• On the two sides of the cap there are yellow leds having the task of signalling<br />

the section where the short-circuit is being detected.<br />

• For detection line connection, ZB/200 base is used.<br />

• The module needs no additional power supply.<br />

• Working voltage: 18 Vdc modulated<br />

• Average absorption: 250 µA<br />

• Operation temperature: -20°C to + 50°C<br />

• Protection degree: IP 43<br />

• Dimensions: Ø 100 mm H.45 mm<br />

ISO/BASE cod. SC4H00121<br />

Short-circuit analyser module for lines for analogue detections; the module<br />

is designed to ensure the operation of the detectors and/or pushbuttons<br />

that are connected to the same line, in case a short-circuit occurs.<br />

• Yellow leds having the task of signalling the section where the short-circuit is<br />

being detected.<br />

• The module is contained in ZB/215 connector block.<br />

• The module needs no additional power supply.<br />

• Working voltage: 18 Vdc modulated<br />

• Average absorption: 250 µA<br />

• Operation temperature: -20°C to + 50°C<br />

• Relative humidity: 95 % Max RH non condensing<br />

• Dimensions: Ø 100 mm H.45 mm<br />

MCR/DIN-2000<br />

ISO/BP<br />

ISO/BASE<br />

29


Modules<br />

ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

ACCESSORIES FOR ADDRESSED SYSTEMS<br />

ISO/C cod. SC2210121<br />

Short-circuit analyser module for lines for analogue detections; the module is<br />

designed to ensure the operation of the detectors and/or pushbuttons that are<br />

connected to the same line, in case a short-circuit occurs.<br />

• Yellow leds having the task of signalling the section where the short-circuit is<br />

being detected.<br />

• The module is contained in S/215 connector block.<br />

• The module needs no additional power supply.<br />

• Working voltage: 18Vdc modulated<br />

• Average absorption: 250 µA<br />

• Operation temperature: -20 to + 50°C<br />

• Relative humidity: 95 % Max RH non condensing<br />

• Dimensions: Ø 100 mm H 45 mm<br />

ISO/BASE-IP cod. SC6G00121<br />

Same as ISO/C but in IP55 version.<br />

• Dimensioni (hxlxp): 90x130x58 mm.<br />

ISO ZB cod. SC4200121<br />

Short-circuit analyser module for lines for analogue detections; the module is<br />

designed to ensure the operation of the detectors and/or pushbuttons that are<br />

connected to the same line, in case a short-circuit occurs.<br />

• The module is contained in a ZB200 base<br />

• The module needs no additional power supply.<br />

• Working voltage: 18Vdc modulated<br />

• Average absorption: 250 µA<br />

• Operation temperature: -20 to + 50°C<br />

• Relative humidity: 95 % Max RH non condensing<br />

• Dimensions: Ø 100 mm H 45 mm<br />

ISO/MINI cod. SC4000121<br />

Short-circuit analyser module for lines for analogue detections; the module is<br />

designed to ensure the operation of the detectors and/or pushbuttons that are<br />

connected to the same line, in case a short-circuit occurs.<br />

• The module is contained in S/215 connector block.<br />

• The module needs no additional power supply.<br />

• Working voltage: 18Vdc modulated<br />

• Average absorption: 250 µA<br />

• Operation temperature: -20 to + 50°C<br />

• Relative humidity: 95 % Max RH non condensing<br />

• Dimensions: Ø 100 mm H 45 mm<br />

30<br />

ISO/C<br />

ISO/BASE-IP


Optical Detector<br />

BPA/212 cod. SD3600121<br />

Low profile smoke optical addressed analogue detector.<br />

• Visual operation signal is provided by two red leds placed on the cap, which<br />

flashes at each call from the central unit.<br />

• The alarm signal from the central unit puts leds on steady.<br />

• Operation principle: Tyndall effect<br />

• Supply voltage: 18 Vdc modulated<br />

• Absorption: 280 µA at rest<br />

• Alarm repetition: O.C. 100 mA max<br />

• Visual alarm repetition: 2 red leds<br />

• Dimensions: Ø 100 x H 45 mm<br />

• Magnetic test<br />

• Operation temperature: –20 to +55 °C<br />

• Relative humidity: 95% max non condensing<br />

• EN 54 part 7 certified<br />

• Associable to following bases: ZB/200, ZB/201, ZB/204<br />

Optical heat detector<br />

ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

DETECTORS FOR ADDRESSED SYSTEMS<br />

BPA/212-T cod. SD5800121<br />

Low profile optic heat addressed analogue detector with heat probe with<br />

intervention temperature.<br />

• Visual operation signal is provided by two red leds placed on the cap, which<br />

flashes at each call from the central unit.<br />

• The alarm signal from the central unit puts leds on steady.<br />

• Operation principle: Tyndall effect+heat probe<br />

• Supply voltage: 18 Vdc modulated<br />

• Absorption: 280 µA at rest<br />

• Alarm repetition: O.C. 100 mA max<br />

• Visual alarm repetition: 2 red leds<br />

• Dimensions: Ø 100 x H 45 mm<br />

• Magnetic test<br />

• Operation temperature: –20 to +55 °C<br />

• Relative humidity: 95% max non condensing<br />

• Protection degree: IP 43<br />

• Associable to following bases: ZB/200, ZB/201, ZB/204<br />

BPA/212<br />

BPA/212T<br />

31


DETECTORS FOR ADDRESSED SYSTEMS<br />

Differential HEAT DETECTOR<br />

ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

BTA/206 cod. SD3400121<br />

Low profile maximum temperature thermo-speedometric and heat addressed<br />

analogue detector.<br />

• Visual operation signal is provided by two red leds placed on the cap, which<br />

flashes at each call from the central unit.<br />

• The alarm signal from the central unit puts leds on steady.<br />

• Operation principle: Double heat probe<br />

• Supply voltage: 18 Vdc modulated<br />

• Absorption: 300 µA at rest<br />

• Alarm repetition: O.C. 100 mA max<br />

• Visual alarm repetition: 2 red leds<br />

• Size: Ø 100 x H 45 mm<br />

• Magnetic test<br />

• Operation temperature: –20 to +55 °C<br />

• Relative humidity: 95% max non condensing<br />

• EN 54 part 5 certified<br />

• Associable to following bases: ZB/200, ZB/201, ZB/204.<br />

REMOTE PANEL<br />

Consolle 54<br />

CONSOLLE/54 cod. KP3400121<br />

Remote Panel useful for repeating and displaying active events and commands<br />

from and to the Central Units of AREA 54 series.<br />

• The panel is housed in a enclosure the design of which was studied in order<br />

that the panel can be used both as a desk panel and wall panel.<br />

• AREA 54 series can manage up to 32 remote panels placed at a maximum<br />

distance of 1200 m.<br />

• Backlit display with 8 lines by 20 characters displays and repeats all events<br />

occurring at the central unit.<br />

• A backlit keyboard provided with specific keys for commands from and to the<br />

Central Unit is available to user.<br />

• From the keyboard, events from the central unit can be acquired, lag time<br />

for alarm can be incremented if programmed at the central unit, sirens can<br />

be entered /cut off, a general reset can be performed and a functional test<br />

can be made on all visual signalling (LED).<br />

• Alarm and Fault status is acoustically signalled by a local buzzer, which is<br />

disabled from the keyboard.<br />

• Supply voltage: 17 to 30 Vdc<br />

• Absorption: 70 mA @ 24 Vdc at rest<br />

• 200 mA @ 24 Vdc with lit keyboard and display<br />

• Connection: 4-lead bus 485<br />

• Alarm output: Relay 1 A @ 30Vdc<br />

• Operation temperature: -5° C to + 50° C<br />

• Relative humidity: 95 % maximum non condensing<br />

• Protection degree: IP 43<br />

• Dimensions (HxLxD): 195 x 290 x 50 mm.<br />

32<br />

BTA/206<br />

CONSOLLE/54


Buttons<br />

ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

BUTTONS FOR ADDRESSED SYSTEMS<br />

P/430 cod.SB2200121<br />

Red alarm analogue pushbutton with recommissioning.<br />

• Visual alarm repetition: red led<br />

• Dimensions (HxLxD): 110 x 110 x 42 mm<br />

• Weight: 100 g<br />

• Average absorption: 100 µA @ 18 Vdc<br />

• Actuation Type: Recommissioning<br />

P/435 cod. SB3900121<br />

Red alarm conventional pushbutton with breaking.<br />

• Visual alarm repetition: red led<br />

• Dimensions (HxLxD): 110 x 110 x 42 mm<br />

• Weight: 100 g<br />

• Average absorption: 100 µA @ 18 Vdc<br />

• Actuation Type: Breaking<br />

P/410 cod. SB3600121<br />

Break glass addressed analogue pushbutton with accident-prevention glass<br />

red in colour.<br />

• Visual alarm repetition: red led<br />

• Average absorption: 100 µA @ 18 Vdc<br />

• Alarm repetition: 100 mA. Max.<br />

• Dimensions (HxLxD): 64x120x555 mm<br />

• Weight: 120 g<br />

• Protection degree: IP 30<br />

P/420 cod. SB2100121<br />

Break glass addressed red alarm analogue pushbutton with transparent<br />

protection cover.<br />

• Visual alarm repetition: red led<br />

• Dimensions (HxLxD): 85x85x52 mm<br />

• Weight: 180 g<br />

• Average absorption: 100 µA @ 18 Vdc<br />

• Actuation Type: Breaking<br />

• Protection degree: IP 54<br />

P/430<br />

P/435<br />

P/410<br />

P/420<br />

33


Centralisation<br />

MRS/232/485-DIN cod. SC9310121<br />

Module to convert signals from RS232 to RS485 allowing serial communication<br />

between apparatuses up to 1,200 mt distance.<br />

• Available also in IP 55 version, MRS/232/485-IP coded.<br />

• Power supply: 12 – 24 Vdc<br />

• Absorption: 50 mA<br />

• Operation: -5° C to + 50 °C<br />

• Dimensions (HxLxD): 67x112x45 mm<br />

MAPPA/54 cod. SW2700121<br />

Software for graphic map system, capable to connect up to 18 central units<br />

through serial line, LAN network or modem.<br />

• For system configuration it is necessary to insert graphic map sheets<br />

(SHEET/54) and devices on field (POINT/54).<br />

MMS/54 cod. SC1B10121<br />

Module enabling the central units of AREA54 series to following functions:<br />

- Connecting and managing a modem<br />

- Connecting central units in Master / Slave configuration.<br />

• Dimensions (hxl): 180X65 mm<br />

• 1 serial connector 485 for connecting Master/Slave central units.<br />

• 1 connector DB9 for connection to modem<br />

MODEM54 cod. CT7300123<br />

56K analogue modem<br />

ADDRESSED <strong>FIRE</strong> <strong>DETECTION</strong> SYSTEMS<br />

ACCESSORIES FOR CENTRALISATION<br />

LAN/54 cod. SC7910121<br />

Module allowing connection to a LAN (Local Area Network) of analogue central<br />

units of AREA 54 series.<br />

• Communication protocol is of TCP/IP UDP type.<br />

• Power Supply: 24 Vdc<br />

• Dimensions (HxLxD): 110x85 mm<br />

TLG/54 cod. SW2800121<br />

Program providing functions for unloading, displaying and printing the chronological<br />

history log of AREA54 central units.<br />

• The program allows to constantly keep under control the operation of central<br />

units, to execute commands remotely and to inquire and modify the status of<br />

AREA54 central units.<br />

• Communication between central units and PC can be implemented by serial<br />

connections, by connections through the network, by connections via Modem<br />

(also simultaneously).<br />

FOGLIO/54 cod. SW2900121<br />

Graphic map leaf from autocad support<br />

PUNTO/54 cod. SW3100121<br />

Graphic map point from autocad support<br />

SOFT/54 cod. SW2300121<br />

Software for local/remote AREA54 programming<br />

34<br />

MODEM54<br />

LAN/54


UNIVERSAL<br />

CONNECTION<br />

BASES<br />

DUCTED<br />

<strong>DETECTION</strong><br />

35


FOR CONVENTIONAL AND AREA54 DETECTORS<br />

ZB/200 cod. SD2700121<br />

Universal base for smoke and thermo-speedometric optical sensors for<br />

conventional analogue and digital systems.<br />

ZB/201 cod. SD2800121<br />

Universal base with 12 Vdc dry contact relay for repeating the alarm status<br />

• The base is suitable for conventional systems and burglar-proof systems. The<br />

base is also suitable for smoke and thermo-speedometric optical sensors.<br />

ZB/204 cod. SD9D00121<br />

Universal base with 24 Vdc dry contact relay for repeating the alarm status.<br />

• The base is suitable for conventional systems and burglar-proof systems. The<br />

base is also suitable for smoke and thermo-speedometric optical sensors.<br />

ZB/210 cod. SD4300121<br />

Universal base with coding for connecting conventional detectors for<br />

analogue systems.<br />

ZB/212 cod. SD1N00121<br />

Base with local alarm signalling.<br />

• The base can manage a LR500 visual repeater. The base must be supplied<br />

through an external power.<br />

ZB/215 cod. ZC7100121<br />

Base support for ZB series low profile bases.<br />

UNIVERSAL CONNECTION BASES<br />

UNIVERSAL CONNECTION<br />

BASES<br />

DUCTED<br />

<strong>DETECTION</strong><br />

DUCTED <strong>DETECTION</strong><br />

R/820 cod. SD3L10121<br />

The analysis chamber for ducted detection was designed to check for the<br />

presence of smoke in air ducts and allows to timely detect a spreading fire.<br />

•<br />

•<br />

•<br />

•<br />

Inside the analysis chamber there can be located analogue and digital optical<br />

smoke detectors, as well as conventional optical smoke detectors. Inside the<br />

chamber there is placed ZB/200 connection base.<br />

Container in thermoplastic material; on container cover there is a window in<br />

plexiglas for sensor local alarm visual control.<br />

Two PVC probes 500 mm long.<br />

Dimensions (HxLxD): 107x81x46 mm<br />

36<br />

R/820


FAP500<br />

DIGITAL<br />

SYSTEM<br />

FAP 54/1 ................................... pag. 40<br />

FAP 54/4 ................................... pag. 41<br />

FAP 54/8 ................................... pag. 41<br />

FAP 54/16 ................................. pag. 41<br />

ACCESSORIES ........................... pag. 42<br />

BUTTONS .................................. pag. 43<br />

DETECTORS .............................. pag. 44<br />

37


FAP500 SYSTEM<br />

FAP500 DIGITAL SYSTEM<br />

From Elkron research, FAP 500 series is born, i.e. a new smoke detection digital system.Within<br />

Elkron fire system there is included from today FAP 500 series, i.e. a new modular, flexible digital<br />

system, EN54-approved and available in 4 control unit models with 1 to 8 loops, all with extension<br />

capability. System main evolution, differentiating the system from anything else present on<br />

the market, is the capability of self-learning the address in any installation mode. In addition, the<br />

system is provided with a short circuit isolator integrated in all components. FAP 500 system<br />

enables both easily interface to shut off systems and assure an excellent protection level. This is<br />

why, with FAP 500, Elkron fire system is also a Hi-protection system.<br />

System high flexibility.<br />

FAP500 system is a clear evolution over control units present on the market, as enabling to connect<br />

all control unit models to the network, interface to shut off systems and assure an excellent<br />

performance level joined to simple installation, programming and management. The system is<br />

modular, flexible and includes 4 control unit models:<br />

• control unit with 1 loop (FAP 541)<br />

• control unit with 2 loops with extension capability to 4 (FAP 544)<br />

• control unit with 4 loops e with extension capability to 8 (FAP 548)<br />

• control unit with 8 loops with extension capability to 16 (FAP 5416)<br />

The line can be connected in 3 different ways, guaranteeing the point (detector, device, pushbutton,<br />

etc...) to be automatically pre-learned:<br />

• line with closed loop<br />

• open lines (entering/exiting connection)<br />

• open lines (parallel connection)<br />

Easy programming.<br />

Thanks to this flexibility, all system needs can be best met, so making installation step much easier.<br />

Each configuration type can be easily programmed via either control unit keyboard or PC.<br />

All control units are prearranged for communicating within the network through a LAN TCP/<br />

IP interface, a communication port for Master/Slave functions, a printer connection port, an<br />

optically isolated RS485 port for interfacing repeater panels and shut off control units, an USB<br />

port for downloading data and system configuration via PC, a communication interface for transmitting<br />

events via GPRS/GSM/PSTN.<br />

All is under control, remotely too, thanks to new software platform enabling Elkron systems to<br />

interact among one another and remotely transmit all system information.<br />

38


FAP500 SYSTEM<br />

FAP500 DIGITAL SYSTEM<br />

FAP 500 SERIES CONTROL UNITS<br />

The new control unit FAP544 is modular that is possible to expand the standard configuration<br />

with functions and peripherics. It is possible to manage a minimum of 2 up to 4 addressed<br />

loop.<br />

Connectibility<br />

RS485 communication port<br />

Communication port for LAN TCP/IP network<br />

Printer connection port<br />

Communication port for MASTER/SLAVE connection<br />

Connection for 16 remote panels<br />

Managing configuration / programming / remote assistance sw via PC<br />

Managing graphic maps / remote management<br />

External communication via GPRS<br />

External communication via PSTN<br />

FOR REMOTE<br />

PANELS (16 MAX)<br />

RS232/485<br />

MODULE<br />

MASTER/SLAVE<br />

FOR EXTINGUISHING<br />

CONTROL UNITS AND<br />

FAP500 CONTROL UNITS<br />

PC PROGRAMMING<br />

CONTROL UNIT RELAY<br />

CONTROLLED RELAY OUTPUT<br />

SELF-POWERED SOUNDER OUTPUT<br />

ALARM RELAY 1<br />

ALARM RELAY 2<br />

FAULT RELAY<br />

PROGRAMMABLE RELAY<br />

RS232<br />

OUTPUT<br />

USB<br />

PRINTER<br />

MODULE<br />

LAN<br />

KEYPAD<br />

PS2<br />

EXPANSION<br />

MODULE<br />

FA128<br />

LOOP LINE<br />

128 POINTS MAX<br />

FDO500 +<br />

SD500<br />

IMO500<br />

MODULE<br />

FDT500 +<br />

SD500R<br />

IO500<br />

MODULE<br />

FM500R<br />

FDOT500 +<br />

SD500R<br />

LR500SI<br />

PANEL<br />

O/A<br />

LR500SI<br />

EXTERNAL<br />

POWER SUPPLY<br />

UNITS<br />

CONTROL<br />

ELECTROMAGNETS<br />

PANEL<br />

LINEAR DETECTORS<br />

39


1 LOOP LINE CONTROL UNIT<br />

FAP541 Control Unit<br />

FAP500 DIGITAL SYSTEM<br />

FAP541 cod. SC6100121<br />

Microprocessor control unit with 1 loop line<br />

• Configuration: 1 loop line (class A) or 2 open lines (class B)<br />

• Possibility of managing up to 128 points for loop (64 for open line).<br />

• Point self-learning and point logic address.<br />

• Backlit graphic display 4 x 40 characters<br />

• Event log: 1000 events<br />

• Chronological history directly shown on display.<br />

• 10 passwords programmable on 3 levels.<br />

• 480 programmable zones.<br />

• USB port for local PC connection for programming via SW<br />

• Possibility of monitoring detector signal/noise ratio level<br />

• Real time clock with built-in buffer battery<br />

• Non volatile memory<br />

• Control unit outputs: 5 (alarm 1, alarm2, failure, programmable (mains<br />

failure/exclusion)<br />

• Internal buzzer<br />

• Programmable alarm threshold: for zone, for individual point<br />

• Exclusion of individual point /zone<br />

• Power supply: 230Vca<br />

• Max. current: 1.5A@24Vcc<br />

• Battery charge limit and battery charge check<br />

• Battery housing: 2 12 @12Vcc batteries<br />

2 • Possibility of implementing at least 2 Km loop with 2 x 1.5 mm screeened<br />

cable<br />

• Noise immunity up to 30Vm<br />

• Common dialogue protocol for all system control units<br />

• Dimensions: 490 (L) x 350 (H) x 145 (D) mm<br />

• COMPLIANT WITH EN54 STANDARDS, part 2 and part 4<br />

40<br />

FAP541


FAP544 Control Unit<br />

FAP544 cod. SC6200121<br />

Microprocessor control unit with 2 loop lines expandable to 4<br />

• Basic configuration: 2 loop lines (class A) or 4 open lines (class B)<br />

• Max. configuration: 4 loop lines (class A) or 8 open lines (class B)<br />

• Possibility of managing up to 128 points for loop (64 for open line).<br />

• Point self-learning and point logic address.<br />

• Backlit graphic display 240*128 - 4.7 “.<br />

• Event log: 1000 events<br />

• Chronological history directly shown on display.<br />

• 10 passwords programmable on 3 levels.<br />

• 480 programmable zones.<br />

• USB port for local PC connection for programming via SW<br />

• Possibility of monitoring detector signal/noise ratio level<br />

• Real time clock with built-in buffer battery<br />

• Non volatile memory<br />

• Control unit outputs: 5 (alarm 1, alarm2, failure, programmable (mains<br />

failure/exclusion)<br />

• Internal buzzer<br />

• Programmable alarm threshold: for zone, for individual point<br />

• Exclusion of individual point /zone<br />

• ON/OFF by password<br />

• Power supply: 230Vac<br />

• Max. current: 2A@24Vdc<br />

• Battery charge limit and battery charge check<br />

• Battery housing: two 12 @12Vdc batteries<br />

• Possibility of implementing at least 2 Km loop with 2 x 0.75 mmÇ cable<br />

(screened and NOT screened)<br />

• Noise immunity up to 30Vm<br />

• Common dialogue protocol for all system control units<br />

• Dimensions: 490 (L) x 350 (H) x 145 (D) mm<br />

• COMPLIANT WITH EN54 STANDARDS, part 2 and part 4<br />

FAP548 Control Unit<br />

FAP548 cod. SC6600121<br />

Microprocessor control unit with 4 loop lines expandable to 8.<br />

• Same as FAP544<br />

FAP5416 Control Unit<br />

FAP500 DIGITAL SYSTEM<br />

4, 8 AND 16 LOOP LINE CONTROL UNITS<br />

FAP5416 cod. SC6700121<br />

Microprocessor control unit with 8 loop lines expandable to 16.<br />

• Same as FAP544<br />

FAP544<br />

41


Expansion module<br />

FA128 cod. SC3310121<br />

1 loop expansion module<br />

• The expansion module enables to expand the control unit by 1 loop line or<br />

2 open lines. 128 points (detectors, push-buttons, interfaces, etc.) can be<br />

connected. The module, to be directly installed on the control unit backplane,<br />

enables the acquisition and control of the connected devices. Connection<br />

with devices can be implemented with closed loop line or with open loop line.<br />

Configuration is made during programming.<br />

Accessories<br />

FAP500 DIGITAL SYSTEM<br />

FAP500 SYSTEM: MODULES AND ACCESSORIES<br />

FKP500 cod. KP5200121<br />

Remote Panel<br />

• The repeating panel enables active and constant monitoring of every event.<br />

The FAP500 control unit can manage up to 16 remote panels; connection<br />

to the control unit and to other panels (if any) is made by means of RS485<br />

opto-isolated port. Panel identification address is made via on board switch.<br />

Information is displayed through backlit display with 4 lines x 40 characters.<br />

Power supplies, exclusions/reset, alarms and failures are indicated by a<br />

series of leds. The user has a keypad fitted with dedicated keys for controls<br />

from/to the control unit.<br />

IO500 cod. SC3A00121<br />

Multipurpose module 1 input/ 1 output<br />

• This module enables to interface on FAP500 digital system, stable conventional<br />

detectors with dry contacts (NC/NO), to connect probes or other devices<br />

fitted with pulse controls. Moreover the same interface can pilot actuators<br />

(e.g.: panels, plates, electromagnets, sirens, etc.) and check the line control.<br />

Each input / output can be programmed.<br />

• Power supply: 10 ÷ 24Vdc<br />

• Absorption: 250 mA @ 24Vdc<br />

• Relay output: 1A, 30Vdc, resistive load<br />

• Alarm repeat output: 12mA max<br />

• Working temperature: -5 ÷ 50 °C<br />

• Relative humidity: 95% max non condensing<br />

IOM500 cod. SC3B00121<br />

Multipurpose module 4 inputs/ 4 outputs<br />

• This interface features the same characteristics as module IO500, it<br />

enables to connect stable conventional detectors with dry contacts (NC/<br />

NO), to connect probes or other devices fitted with pulse controls and to<br />

pilot actuators (e.g.: panels, plates, electromagnets, sirens, etc.) and check<br />

the line control, but it features 4 programmable inputs and 4 programmable<br />

outputs.<br />

RS232/485 cod. IT1410121<br />

RS232/485 interface for MASTER/SLAVE and remote panel<br />

42<br />

FA128<br />

IO500


FAP500 SYSTEM: MODULES AND ACCESSORIES<br />

Accessories<br />

SOFT/FAP500 cod. SW3500121<br />

Configuration SW<br />

• This software enables to acquire the system characteristics by reading<br />

the control unit data; to unload and to programme the configuration and<br />

parameters of each individual point<br />

MAPPE/FAP500 cod. SW3600121<br />

Supervision software with graphic maps<br />

• This software enables full network management of one or more control units.<br />

It is possible to manage and assist the system in local or remotely.<br />

LAN/TCP/IP500 cod. IT1510121<br />

LAN/TCP/IP interface<br />

• It enables to connect several control units on a LAN network.<br />

ITS500 cod. IT1610121<br />

Printer interface.<br />

MGSM500 cod. CT6010121<br />

Modem interface for GSM.<br />

MPSTN500 cod. CT5910121<br />

Modem interface for PSTN.<br />

FAP500 SYSTEM: BUTTONS<br />

Buttons<br />

FAP500 DIGITAL SYSTEM<br />

FM500 cod. SD6000121<br />

Break glass manual pushbutton, complete with self-learning circuit<br />

• Fire alarm pushbuttons are used for signalling an alarm manually. To use the<br />

break glass pushbutton model just press the glass in the middle in order to<br />

break it and to operate the internal switch. These pushbuttons are provided<br />

with a special tool to be used to perform the TEST, to open the cover and to<br />

replace the glass. The alarm state is shown by the switching on of a red LED.<br />

Compliant with Standards: EN54 part 11<br />

FMR500 cod. SB6100121<br />

Manual recommissioning pushbutton, complete with self-learning circuit and<br />

short-circuit isolator.<br />

•<br />

To use the recommissioning pushbutton model just press the glass in the<br />

middle in order to push it inwards, thereby operating the switch. These<br />

pushbuttons are provided with a special tool to be used to perform the TEST<br />

and to replace the glass. The alarm state is shown by the switching on of a<br />

red LED. Compliant with Standards: EN54 part 11<br />

FM500<br />

FMR500<br />

43


Photo-optical smoke detector<br />

FDO500 cod. SD4800121<br />

Low profile photo-optical smoke detector, complete with self-learning circuit<br />

and short-circuit isolator.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

Smoke detectors work according to the light scattering principle caused by<br />

smoke particles present in the air. The smoke detector has the automatic gain<br />

control function; a microcontroller calculates reading compensation to keep<br />

constant sensitivity and corrects any level increase due to dust depositing<br />

into the analysis cell. Smoke detectors shall be installed in places protected<br />

against draughts which may divert the flow of combustion particles and in<br />

places where the common activities performed do not cause gas material<br />

fires.<br />

Power supply: 20Vdc (modulated voltage between -15% and + 10%)<br />

Average absorption at rest: 250 mA@20Vdc<br />

Absorption at alarm: 2mA@20Vdc<br />

Two-colour led: red alarm - green regular operation<br />

Relative humidity max: 93%<br />

Working temperature: 0 ÷ 50°C<br />

Weight: 70 g<br />

Dimensions: ø 90 x 31 (H) mm<br />

Certificato EN54 parte 7, certification number: 1293-CPD-0082<br />

RIVELATORI CONVENZIONALI<br />

Heat detector<br />

FAP500 DIGITAL SYSTEM<br />

FAP500 SYSTEM: DETECTORS<br />

FDT500 cod. SD5700121<br />

Low profile heat detector, complete with self-learning circuit and short-circuit<br />

isolator.<br />

• Heat detectors monitor the temperature values in the area where they are<br />

installed.<br />

• A microcontroller analyses and compares the signal received from a NTC<br />

type temperature detector and activates the alarm if the read temperature<br />

exceeds 58°C.<br />

• Power supply: 20Vdc (modulated voltage between -15% and + 10%)<br />

• Average absorption at rest: 250 mA@20Vdc<br />

• Absorption at alarm: 2mA@20Vdc<br />

• Static alarm threshold: 58°<br />

• Two-colour led: red alarm - green regular operation<br />

• Relative humidity max: 93%<br />

• Working temperature: 0 ÷ 50°C<br />

• Weight: 70 g<br />

• Dimensions: ø 90 x 40 (H) mm<br />

• Compliant with EN54 Standards, part 5 class A1S, certification number:<br />

1293-CPD-0084.<br />

44<br />

FDO500<br />

FDT500


Thermo-speedometric detector<br />

FDTD500 cod. SD9000121<br />

Low profile thermo-speedometric detector, complete with self-learning circuit<br />

and short-circuit isolator.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

Thermo-speedometric detectors monitor temperature rise in the area where<br />

they are installed. A microcontroller analyses and compares the signal<br />

received from a NTC type temperature detector and activates the alarm if<br />

the read temperature rise exceeds 5°C per minute.<br />

Power supply: 20Vdc (modulated voltage between -15% and + 10%)<br />

Average absorption at rest: 250 mA@20Vdc<br />

Absorption at alarm: 2mA@20Vdc<br />

Static alarm threshold: 58°<br />

Two-colour led: red alarm - green regular operation<br />

Relative humidity max: 93%<br />

Working temperature: 0 ÷ 50°C<br />

Weight: 70 g<br />

Compliant with EN54 Standards, part 5 class A1R, certification number:<br />

1293-CPD-0085.<br />

Optical- heat detector<br />

FDOT500 cod. SD9K00121<br />

Low profile optical- heat detector, complete with self-learning circuit and<br />

short-circuit isolator.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

FAP500 DIGITAL SYSTEM<br />

FAP500 SYSTEM: DETECTORS<br />

Double technology detectors (smoke-heat) base their operating principle on<br />

the light scattering principle caused by smoke particles present in the air<br />

(TYNDALL effect) and on temperature monitoring within the area where they<br />

are installed. A microcontroller analyses and compares the signal received<br />

from a NTC type temperature detector and activates the alarm if the read<br />

temperature exceeds 58°C. The smoke detector has the automatic gain<br />

control function; a microcontroller calculates reading compensation to keep<br />

sensitivity constant in time.<br />

Power supply: 20Vdc (modulated voltage between -15% and + 10%)<br />

Average absorption at rest: 250 mA@20Vdc<br />

Absorption at alarm: 2mA@20Vdc<br />

Static alarm threshold: 58°<br />

Two-colour led: red alarm - green regular operation<br />

Relative humidity max: 93%<br />

Working temperature: 0 ÷ 50°C<br />

Weight: 70 g<br />

Dimensions: ø 90 x 40 (H) mm<br />

Compliant with EN54 standards part 7 and part 5 class A1, certification<br />

number: 1293-CPD-0083<br />

FDTD500<br />

FDOT500<br />

45


FAP500 SYSTEM: BASES FOR DETECTORS<br />

Standard base<br />

SD500 cod. SD4K00121<br />

Digital detector standard base.<br />

• The base is standard for all digital detectors of the FAP500 series.<br />

• Material: ABS<br />

• Colour: white<br />

• Dimensions: 90 mm<br />

SD500M cod. SD4S00121<br />

Digital detector standard base, FAP500 series - package with 10 pcs.<br />

SD500R cod. SD5K00121<br />

Digital detector standard base with alarm repetition.<br />

• The base is standard for all digital detectors of the FAP500 series, its output<br />

enables to directly pilot (through the loop supply) the outdoor gem LR500SI<br />

• Material: ABS<br />

• Colour: white<br />

• Dimensions: 90 mm<br />

• Alarm repetition output: 12 mA@24Vdc<br />

SD500-RM cod. SD6S00121<br />

Digital detector standard base with alarm repetition, FAP500 series -<br />

package with 10 pcs<br />

SD515 cod. SD2V00121<br />

Base support for series 500 bases<br />

46<br />

FAP500 DIGITAL SYSTEM


EXTINGUISHING<br />

CONTROL<br />

UNIT<br />

47


EXTINGUISHING<br />

CONTROL UNIT<br />

48<br />

UNBLOCK<br />

PUSH<br />

BUTTON<br />

EXTINGUISHING CONTROL UNIT<br />

OUT 2<br />

OUT 1<br />

LOOP 1<br />

FDT500 FDT500<br />

TM24<br />

FMR500 FMR500<br />

REMOTE<br />

CONTROL<br />

SWITCH<br />

EXTINGUISHING<br />

SYSTEMS<br />

IO500


CDS CONTROL UNIT<br />

EXTINGUISHING CONTROL UNIT<br />

CDS cod. SC3600121<br />

Extinguishing control panel fitted with one module expandable to 2<br />

• CDS extinguishing control panel is a non-expandable, 1 loop, microprocessorbased<br />

control panel that shares all FAP500 system devices and also<br />

incorporates a extinguishing module with provisions for expansion to 2.<br />

• CDS has been designed so as to fully comply with EN 12094-1 and EN54-4<br />

European Norms.<br />

• Certification No.: 0051-CPD-0177.<br />

<strong>FIRE</strong> EXTINGUISHING MODULE CHARACTERISTICS<br />

• Flux meter input<br />

• Pressure switch input<br />

• Emergency extension input<br />

• Manual discharge activation input<br />

• Input for discharge activation through an external control panel<br />

• Release “ON” relay (NO or NC contact, 1A max)<br />

• Emergency extension relay (NO or NC contact ,1A max)<br />

• Evacuation siren output (250 mA max.)<br />

• Release output 1 (Pilot, 750mA max)<br />

• Release output 2 (Solenoid valve, 750mA max)<br />

<strong>DETECTION</strong> LINES CHARACTERISTICS<br />

• Configuration: 1 loop line (class A) or 2 open lines (class B).<br />

• Possibility of managing up to 128 points per loop.<br />

• Point self-addressing and point logic address.<br />

• Backlit display: 4 x 40 characters<br />

• Event log: 1.000 events<br />

• Chronological event log available on the display directly.<br />

• 10 passwords programmable on 3 levels.<br />

• 480 programmable zones.<br />

• USB port for connection to local PC for programming via SW<br />

• Possibility of monitoring detector signal/noise ratio level<br />

• Real time clock with built-in buffer battery<br />

• Non-volatile memory<br />

• Control panel outputs: 5 (alarm 1, alarm2, failure, programmable (mains<br />

failure/exclusion)<br />

• Internal buzzer<br />

• Programmable alarm threshold: for zone, for individual point<br />

• Exclusion of individual point /zone<br />

• Power supply: 230Vac<br />

• Max. current: 1.5A@24Vdc<br />

• Battery charge limit and battery charge check<br />

• Battery housing: two 12 @12Vdc batteries<br />

• Possibility of implementing max 2 Km loop with 2 x 0.75 mm² with screened<br />

cable<br />

• Noise immunity up to 30Vm<br />

• Common communication protocol for all system control panels<br />

• Dimensions: 490 (L) x 350 (H) x 145 (D) mm<br />

ESPCDS cod. SC3500121<br />

Expansion to 1 module for extinguishing control panel.<br />

CDS<br />

ESPCDS<br />

49


GAS, LIQUIDS,<br />

HEAT AND<br />

LINEAR<br />

DETECTORS<br />

AND CONTROL<br />

UNITS<br />

GAS <strong>DETECTION</strong> CONTROL UNIT pag. 52<br />

TOXIC AND EXPLOSIVES GAS DET. .. pag. 53<br />

FLAME DETECTOR ..................... pag. 56<br />

LIQUID PRESENCE DETECTOR .... pag. 57<br />

SPECIAL HEAT DETECTOR .......... pag. 57<br />

LINEAR DETECTOR .................... pag. 59<br />

SUCTION SYSTEMS ................... pag. 62<br />

51


Gas Detection Control Units<br />

DETECTORS AND CONTROL UNITS<br />

ATEX VERSION CONTROL UNITS<br />

ST/PL4 cod. SC6R00123<br />

Gas detection central unit allowing the connection of 4 minimum number to<br />

8 maximum number of inflammable toxic gasses or oxygen detectors (through<br />

optional board) with 4-20 mA proportional output.<br />

• For each input it is possible to set the type of detector, suitable measure<br />

range and alarm level values.<br />

• Concentration values measured are shown on a backlit liquid crystal display.<br />

• The central unit has 5 relay outputs, 4 of which are associated to Failure,<br />

Alarm 1, Alarm 2, Alarm 3 and one is an auxiliary relay output that can be<br />

associated to one of the four above statuses.<br />

• By adding an optional module, in addition to the 4 inputs there are also<br />

implemented 16 open collector outputs.<br />

• Housing: Metallic enclosure<br />

• Dimensions (hxlxd): 225x360x110 mm<br />

• Display: backlit LCD with 16 characters for 2 lines<br />

• Power supplay: 230 Vac<br />

• Absorption: 80 mA at rest, 160 mA on alarm status, 240 mA with<br />

expansion board<br />

• Relay outputs: 1 A @ 24 Vdc 5 A @ 24 Vdc (relay AUX)<br />

• Operation temperature: -0 to - 40°C<br />

• Relative humidity: 15-85% non condensing<br />

ST/PL4/ESP cod. SC7R10123<br />

Expansion module for 4 inputs, 16 O.C. outputs that can be set for Alarm 2<br />

or Alarm 3 ST/PL4 for central unit.<br />

• O.C. outputs: 250 mA<br />

STG/MTSLB cod. SC8R00123<br />

Gas detection central unit allowing the connection of 8 minimum number to<br />

104 maximum number of inflammable toxic gasses or oxygen detectors with<br />

4-20 mA proportional output.<br />

• The connection is through (optional) remote concentrators arranged on<br />

RS485 serial line.<br />

• The central unit has inside it 4 output relays to interface towards the field,<br />

and 4 open collector outputs.<br />

• The unit can be configured with detectors that differ from one another as<br />

both gas detected and activation thresholds.<br />

• Both explosive and toxic gas detectors can be configured.<br />

• The central unit can store up to 800 events.<br />

• Housing: Metallic enclosure<br />

• Dimensions (hxlxd): 420x440x140 mm<br />

• Display: backlit LCD with 256x64 dots<br />

• Power supplay: 230 Vac<br />

• Expansibility: Up to 64 O.C. outputs with 8 STG/OUT16 optional modules<br />

• Operation temperature: -0 to - 40°C<br />

• Relative humidity: 15-85% non condensing<br />

52<br />

ST/PL4<br />

STG/MTSLB


ATEX VERSION CONTROL UNITS<br />

Accessories for ATEX control units<br />

STG/IN8 cod. SC9R10123<br />

Remote module for 8 board inputs<br />

DETECTORS AND CONTROL UNITS<br />

STG/OUT16 cod. SC1S10123<br />

Remote module for 16 open collector programmable board outputs<br />

STG/BOX cod. ST0510123<br />

Metallic enclosure for containing a STG/IN8 or STG/OUT16 module<br />

WMB/138V15 cod. ST0610123<br />

Metallic enclosure with 12 Vdc 1.5 A supply for containing a STG/IN8 or<br />

STG/OUT16 module.<br />

TOXIC AND EXPLOSIVES GAS DETECTORS<br />

Gas detectors are used to detect the presence of combustibles in concentrations<br />

that can be expressed as a percentage of Explosiveness Lower Limit (%ELL) and<br />

of toxics that can be expressed as parts per million (ppm) or in the detection of<br />

oxygen deficiency or excess.<br />

For explosive mixtures detectors a catalytic sensor is used, while for toxics<br />

detectors an electrochemical cell sensor is used.<br />

The detector is fully controlled by a 10 bit microprocessor. The detectors provide<br />

either a current proportional output (4-20 mA) or relay contacts through an<br />

optional board.<br />

GAS DETECTORS, EX II 3GD TYPE<br />

S1604VB cod. SD2T00123<br />

Petrol vapours detector 4-20 mA, 0-100% LEL<br />

• Catalytic sensor: Nemoto.<br />

• Absorption: 130 mA@12Vcc.<br />

• STS3REL relay board cannot be used.<br />

S2096PR cod. SD5T00123<br />

Propane gas detector 4-20 mA, 0-100% LEL<br />

• Catalytic sensor: Nemoto.<br />

• Absorption: 130 mA@12Vcc.<br />

S2096BU cod. SD6T00123<br />

Butane gas detector 4-20 mA, 0-100% LEL<br />

• Catalytic sensor: Nemoto.<br />

• Absorption: 130 mA@12Vcc.<br />

S1606CO cod. SD7T00123<br />

CO (Carbon Monoxide) detector 4-20 mA, 0-300 ppm<br />

• Electrochemical cell sensor.<br />

• Absorption: 30 mA@12Vcc.<br />

• STS3REL relay board cannot be used.<br />

EX II 3GD<br />

53


GAS DETECTORS, EX II 3GD TYPE<br />

S2096ME cod. SD9S00123<br />

Methane gas detector 4-20 mA, 0-100% LEL<br />

• Catalytic sensor: Nemoto.<br />

• Absorption: 130 mA@12Vcc.<br />

S1702VB cod. SD3T00123<br />

Petrol vapours detector 4-20 mA, 0-100% LEL<br />

• Pellistor sensor.<br />

• Absorption: 30 mA@12Vcc.<br />

• Alarm output: 2 relays 1A@30Vcc.<br />

• Fault output: 1 relay 1A@30Vcc.<br />

• Suitable for parking lots.<br />

S2096GP cod. SD4T00123<br />

LPG gas detector 4-20 mA, 0-100% LEL<br />

• Catalytic sensor: Nemoto.<br />

• Absorption: 130 mA@12Vcc.<br />

DETECTORS AND CONTROL UNITS<br />

TOXIC AND EXPLOSIVES GAS DETECTORS<br />

S1703CO cod. SD8T00123<br />

CO (Carbon Monoxide) detector 4-20 mA, 0-300 ppm<br />

• Electrochemical cell sensor.<br />

• Absorption: 30 mA@12Vcc.<br />

• Alarm output: 2 relays 1A@30Vcc.<br />

• Fault output: 1 relay 1A@30Vcc.<br />

• Suitable for parking lots.<br />

MAIN CHARACTERISTICS OF GAS DETECTORS<br />

Power supply 12 – 24Vcc – 20% + 15%<br />

Auto-zero routine Zero drift compensation<br />

Light indications Blinking LED<br />

Precision ± 10% full scale<br />

Warm-up time 5 minutes<br />

Stabilization time < 2 minutes<br />

Response time < 15 sec. T50; < 25 sec T90 (flammable gas version)<br />

Air velocity < di 6 mS<br />

Digital filter Sampled values variable averages<br />

Resolution 1.024 points<br />

IP protection IP55<br />

Weight 350 g<br />

Dimensions (L) x (H) x (D) mm 106 x 170 x 65<br />

Reference Standards EN50014 EN50018 EN50021 (essential safety<br />

requirements EEx-n) / EN61779-1/4 (performances)<br />

Atex marking CE 722 Ex II 3GD Ex nA d IIC T6 IP55 T85°C<br />

54


TOXIC AND EXPLOSIVES GAS DETECTORS<br />

GAS DETECTORS, Ex II 2GD TYPE<br />

S2097VB cod. SD1U00123<br />

Petrol vapours detector 4-20 mA, 0-100% LEL<br />

• Catalytic sensor: Nemoto.<br />

• Absorption: 130 mA@12Vcc.<br />

S2097ME cod. SD9T00123<br />

Methane gas detector 4-20 mA, 0-100% LEL<br />

• Catalytic sensor: Nemoto.<br />

• Absorption: 130 mA@12Vcc.<br />

S2131CO cod. SD5U00123<br />

CO (Carbon Monoxide) detector 4-20 mA, 0-500 ppm<br />

• Electrochemical cell sensor.<br />

• Absorption: 30 mA@12Vcc.<br />

S2097PR cod. SD3U00123<br />

Propane gas detector 4-20 mA, 0-100% LEL<br />

• Catalytic sensor: Nemoto.<br />

• Absorption: 130 mA@12Vcc.<br />

S2097GP cod. SD2U00123<br />

LPG gas detector 4-20 mA, 0-100% LIE<br />

• Catalytic sensor: Nemoto.<br />

• Absorption: 130 mA@12Vcc.<br />

S2097BU cod.SD4U00123<br />

Butane gas detector 4-20 mA, 0-100% LEL<br />

• Catalytic sensor: Nemoto.<br />

• Absorption: 130 mA@12Vcc.<br />

DETECTORS AND CONTROL UNITS<br />

MAIN CHARACTERISTICS OF GAS DETECTORS<br />

Power supply 12 – 24Vcc – 20% + 15%<br />

Auto-zero routine Zero drift compensation<br />

Light indications Blinking LED<br />

Precision ± 10% full scale<br />

Warm-up time 5 minutes<br />

Stabilization time < 2 minutes<br />

Response time < 15 sec. T50; < 25 sec T90 (flammable gas version)<br />

Air velocity < di 6 mS<br />

Digital filter Sampled values variable averages<br />

Resolution 1.024 points<br />

IP protection IP66<br />

Weight 950 g<br />

Dimensions (L) x (H) x (D) mm 110 x 135 x 80<br />

Reference Standards EN50014 EN50018 EN50021 (essential safety<br />

requirements EEx-n) / EN61779-1/4 (performances)<br />

Atex marking CE 722 Ex II 2GD Ex d IIC Ex tD A21 IP65 T85°C<br />

EX II 2GD<br />

55


TOXIC AND EXPLOSIVES GAS DETECTORS<br />

Accessories for gas detectors<br />

DETECTORS AND CONTROL UNITS<br />

ST/S3REL cod. SC5R10123<br />

Board with three relays for gas detectors.<br />

• It allows to have contacts free from voltage.<br />

• The first output is associated to failure or Watch-Dog. The second output can<br />

be associated to either alarm 1 or alarm 2 of detector. The third output can<br />

be associated to either alarm 2 or alarm 3 of detector.<br />

• Relay contacts current carrying capacity: 50mA @ 24 Vdc; 100 mA @ 12<br />

Vdc.<br />

VAL TEST cod. SI7100123<br />

Test kit containing instruments necessary to execute requested functionality<br />

tests.<br />

• It contains a flowmeter valve and a fitting suitable to connect the tanks to the<br />

detectors, in order to create a well defined titrated atmosphere.<br />

INFRARED FLAME DETECTOR<br />

RU-ADPE cod. SD7100121<br />

Flame detector immediately responding to infrared thermal radiation released<br />

by fire. The detector is tuned to flame pulses in order to ignore sunlight<br />

and lamps.<br />

• It is contained in IP66 explosion proof enclosure.<br />

• It needs 24 Vdc supply, with wide tolerance on its value, and provides two<br />

types of outputs: a wide range switching contact SPDT and a static signal on<br />

NPN collector.<br />

• Both outputs go into alarm after a certain lag and go back to a rest condition<br />

as fire is over.<br />

• Lag time is normally calibrated to 5 seconds; however, it can be ranging 1<br />

to 10 seconds.<br />

• Sensitivity is calibrated to 2 - 3%, i.e. a 10 cm flame at a 5 m distance, or a<br />

20 cm flame at a 10 m distance.<br />

• View field is a 90° cone; however, beyond 90°, the detector can still see,<br />

although with reduced sensitivity; and, by reflection, it can even see zones in<br />

shade behind obstacles.<br />

• On detector front side, a red LED warns about test or alarm status.<br />

• Casing: explosion proof aluminium alloy.<br />

• Painting: epoxy, grey RAL7035.<br />

• Implementation: II 2 GD EEx-d IIC T6 IP66.<br />

• Certified: CESI 01 ATEX 036.<br />

• Compliance with: directive ATEX 94/9 CENELEC EN 50014 (CEI 31.8) EN<br />

50018 (CEI 31.1)<br />

• Dimensions (mm): 230 x 230 x 154h main body only.<br />

• Weight: 10 kg including detector.<br />

• Cables input: 1’’ Gas.<br />

56


LIQUID DETECTOR<br />

Liquid detector<br />

DETECTORS AND CONTROL UNITS<br />

RA/209 cod. SD2B00121<br />

Electronic detector to detect the presence of (uninflammable) liquids.<br />

• Detecting the presence of water is through 4 support gilt feet, which put the<br />

detector into alarm by switching a relay placed inside it.<br />

• For higher protection, RA/209 model is provided with a humidity detector<br />

having a sensivity that can be regulated by an inner trimmer.<br />

• Facility for connecting 10 external probes of RA/209S model.<br />

• Container material: Thermoplastic, white colour<br />

• Operation voltage: 12 - 27 Vdc<br />

• Average absorption: 3.5 mA at 27 Vdc<br />

• Operation temperature: +5 to +50 °C<br />

• Dimensions: 64 x 96 x 30 mm<br />

SPECIAL HEAT DETECTOR<br />

Heat Detectors<br />

RTS/2 cod. SD2C00123<br />

IP65 Special heat detector based on the deformation of a bimetallic element<br />

which closes a dry contact as the temperature is reached. This makes the<br />

detector easy to be interfaced with any board type.<br />

• The heat detector is suitable for detection in environments where potentially<br />

explosive atmospheres may be present. Its construction is complying with<br />

sector specific regulations (ATEX).<br />

• The detector can operate based on the type of heat probe being used as<br />

follows:<br />

• DF: Gradient detector. The intervention only occurs when temperature<br />

increment is higher than 13 °C per minute.<br />

• SD: Semidifferential detector. The intervention always occurs as calibration<br />

temperature is reached; further, an intervention lead occurs when temperature<br />

increment is higher than 15°C per minute.<br />

• MAX: Maximum temperature detector.The intervention only occurs when<br />

calibration temperature is reached.<br />

• Code SD2500123 is referred to a detector with a 60° C calibration<br />

temperature. Different grades are available to specify in the command.<br />

• Operation principle: Bimetallic element deformation<br />

• Protection degree: IP 65<br />

• Working temperature: 190 C° MAX<br />

• Relative humidity: 98%<br />

• Weight: 0,9 Kg<br />

• Bimetallic component: Nilvar-Brass<br />

• Regulation range: -40 + 190 C°<br />

• Intervention threshold: On Request /mod SD Max 88 C°<br />

• Alarm condition: Normally closed contact<br />

• Contacts current carrying capacity: 2,5 A<br />

• Working voltage: 48 Vdc<br />

• Enclosure material: Aluminium alloy<br />

• Dimensions: 110 x 13 x 70 mm<br />

RTS72<br />

57


Heat detector<br />

RTS/4 cod. SD4C00123<br />

IP55 heat detector based on the deformation of a bimetallic element which<br />

closes a dry contact as the temperature is reached.<br />

• This makes the detector easy to be interfaced with any board type.<br />

• The detector can operate based on the type of heat probe being used as<br />

follows:<br />

DF: Gradient detector. The intervention only occurs when temperature<br />

increment is higher than 13 °C per minute.<br />

SD: Semidifferential detector. The intervention always occurs as calibration<br />

temperature is reached; further, an intervention lead occurs when temperature<br />

increment is higher than 15°C per minute.<br />

MAX: Maximum temperature detector. The intervention only occurs when<br />

calibration temperature is reached.<br />

• Code SD4J00123 is referred to a detector with a 60° C calibration<br />

temperature. Different grades are available to specify in the command.<br />

• Operation principle: Bimetallic element deformation<br />

• Protection degree: IP 55<br />

• Working temperature: 190 C° MAX<br />

• Relative humidity: 98%<br />

• Weight: 0,4 Kg<br />

• Bimetallic component: Nilvar-Brass<br />

• Regulation range: -40 + 190 C°<br />

• Intervention threshold: On Request /mod SD Max 88 C°<br />

• Alarm condition: Normally closed contact<br />

• Contacts current carrying capacity: 2,5 A<br />

• Working voltage: 48 Vdc<br />

• Enclosure material: Aluminium alloy<br />

• Dimensions: 92x167x67 mm<br />

RTS/6 cod. SD3C00123<br />

IP65 Special heat detector based on the deformation of a bimetallic element<br />

which closes a dry contact as the temperature is reached. This makes the<br />

detector easy to be interfaced with any board type.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

DETECTORS AND CONTROL UNITS<br />

SPECIAL HEAT DETECTOR<br />

The heat detector is suitable for detection in environments where potentially<br />

explosive atmospheres may be present. Its construction is complying with<br />

sector specific regulations (ATEX).<br />

Code SD7E00123 is referred to a detector with a 60° C calibration<br />

temperature. Different grades are available to specify in the command.<br />

Heat probe is UL/FM certified.<br />

Operation principle: Bimetallic element deformation<br />

Relative humidity: 98%<br />

Weight: 0,4 Kg<br />

Bimetallic component: Nilvar<br />

Regulation range: on order fixed calibration<br />

Alarm condition: Normally closed contact<br />

Contacts current carrying capacity: 2 A<br />

Working voltage: 24 Vdc<br />

Sensor material: steel<br />

Enclosure material: Aluminium alloy<br />

Dimensions: 100 x 193,5 x 70 mm<br />

58<br />

RTS/4


SPECIAL HEAT DETECTOR<br />

Heat Detector<br />

RLB/1 cod. SD6P00121<br />

Linear heat detector, 68°C calibration (certified)<br />

• Packaging: 100 m skein<br />

RLB/2 cod. SD5P00121<br />

Linear heat detector, 105°C calibration (certified)<br />

• Packaging: 100 m skein<br />

LINEAR DETECTORS<br />

Smoke Linear Detector<br />

DETECTORS AND CONTROL UNITS<br />

S/2-100 + INT8C cod. IL1500123<br />

Linear detector suitable for all environments characterised in high ceilings,<br />

where using smoke optical detectors results to be particularly hard.<br />

• The system includes three units: Transmitting unit (TX), Receiving unit (RX),<br />

co-ordination unit (not including INT8C/24V interface module).<br />

• The operation principle of linear detector is based on TX units to emit a<br />

beam of infrared rays. The beam runs through the zone to be monitored<br />

and radiates Receiving unit (RX). On running through monitored zone, the<br />

beam collects information about possible fire arising and carries it to RX. RX<br />

processes this information and draws from it a number of electrical signals,<br />

each corresponding to a single fire sign examination. Successive processing<br />

allows to diagnose the presence of smoke in monitored environment.<br />

• On Transmitting unit there are present following leds: Power supply signalling<br />

green led, Receiving unit status repetition yellow led.<br />

• On Receiving unit there are present following leds: Power supply signalling<br />

green led, Emitted and received IR intensity level yellow led, Fire alarm red<br />

led.<br />

• Linear detector is suitable for lengths of 5 m to 150 m.<br />

• Maximum operative width: 15 m.<br />

• High aligning facility.<br />

• Brackets, for improved wall application, already included.<br />

• Obligatory connection interface INT/8C (not included).<br />

• Obligatory calibration instrument ADM (not included).<br />

• Operation voltage: 24 Vdc<br />

• Absorption in mA Tx: 5-15m 20,0 55-75m 24,0<br />

15-35m 21,8 75-100m 38,6<br />

35-55m 22,7 100-150m 65,5<br />

• Absorption in mA Rx: Normal operation 47,7 - Fault 66,7 - Alarm 64,0.<br />

• Operation temperature: da -20 a + 55 C°<br />

• Operative homologation: EN 54/12<br />

• Protection degree: IP 44<br />

• Weight: Tx Unit 1,257 g, Rx Unit 1,447 g.<br />

• Dimensions with bracket: Tx 224 x 119 x 313 mm<br />

Rx 224 x 119 x 313 mm<br />

• Dimensions without bracket: Tx 220 x 119 x 148 mm.<br />

•<br />

Rx 220 x 119 x 148 mm<br />

Certificate EN54 part 12 Certificate N° 0786 - CPD - 20215.<br />

S/2-100<br />

59


LINEAR DETECTORS<br />

Fire and smoke linear detectors<br />

DETECTORS AND CONTROL UNITS<br />

SF-100 + INT8C cod. IL1400123<br />

Fire and smoke linear detector.<br />

• The system includes three units: Transmitting unit (TX), Receiving unit (RX),<br />

co-ordination unit (not including INT8C/24V interface module).<br />

• The operation principle of linear detector is based on TX units to emit a<br />

beam of infrared rays. The beam runs through the zone to be monitored<br />

and radiates Receiving unit (RX). On running through monitored zone, the<br />

beam collects information about possible fire arising and carries it to RX. RX<br />

processes this information and draws from it a number of electrical signals,<br />

each corresponding to a single fire sign examination.<br />

• Successive processing allows to diagnose the presence of smoke in monitored<br />

environment.<br />

• On Transmitting unit there are present following leds: Power supply signalling<br />

green led. Receiving unit status repetition yellow led<br />

• On Receiving unit there are present following leds: Power supply signalling<br />

green led. Emitted and received IR intensity level yellow led. Fire alarm red<br />

led.<br />

• Linear detector is suitable for lengths of 5 m to 150 m.<br />

• Maximum operative width: 15 m.<br />

• High aligning facility.<br />

• Brackets, for improved wall application, already included.<br />

• Obligatory connection interface INT/8C (not included).<br />

• Obligatory calibration instrument ADM (not included).<br />

• Operation voltage: 24 Vdc<br />

• Absorption in mA Tx: 5-15m 20,0<br />

15-35m 21,8<br />

35-55m 22,7<br />

55-75m 24,0<br />

75-100m 38,6<br />

100-150m 65,5<br />

• Absorption in mA Rx: Normal operation 47,7 - Fault 66,7 - Alarm 64,0.<br />

• Operation temperature: from -20 to + 55 C°<br />

• Operative homologation: EN 54/12<br />

• Protection degree: IP 44<br />

• Weight: Tx Unit 1,257 g, Rx Unit 1,447 g.<br />

• Dimensions with bracket: Tx 224 x 119 x 313 mm<br />

Rx 224 x 119 x 313 mm<br />

• Dimensions without bracket: Tx 220 x 119 x 148 mm.<br />

•<br />

Rx 220 x 119 x 148 mm<br />

Certificate EN54 part 12 N° 0786 - CPD - 20215.<br />

60<br />

SF-100


LINEAR DETECTORS<br />

Accessories<br />

INT8C/24V cod. IL1010123<br />

Interface module allowing the connection and operation of the Tx and Rx<br />

units of smoke linear detector.<br />

• The module has two relays inside it: one alarm relay and one failure relay<br />

to be used for connecting the apparatus to conventional central units, or<br />

analogue or digital input modules.<br />

• Failure relay can be either normally energised (active safety) or normally not<br />

energised.<br />

• Facility for delaying the failure by 0 to 90 seconds through a second jumper.<br />

• Operation principle: 24 Vdc<br />

• Absorption with not energised out of order relay: Normal operation 16,4mA<br />

@ 24 Vdc, Alarm: 22,4mA @ 24 Vdc, Failure: 22,2mA @ 24 Vdc<br />

• Absorption with energised out of order relay: Normal operation 25,0mA @<br />

24 Vdc, Alarm: 15,7mA @ 24 Vdc, Failure: 30,6mA @ 24 Vdc.<br />

• Dimensions (hxlxp): 130 x 130 x 58 mm.<br />

ADM cod. IL1110123<br />

ADM instrument, associated to an analogue tester, was designed in order<br />

to best perform the management functions of sensitivity thresholds required<br />

by the nature of environmental disturbances present in environments to be<br />

protected.<br />

• The use of ADM instrument is necessary for models: ES 25-1; ES 50; ES<br />

100; S/2-100 and SF-100.<br />

• Operation voltage: 8-12 V<br />

• Battery down indication: < 8 V<br />

• Typical absorption : 2 mA<br />

• Absorption: 1.6 – 2,2 mA max<br />

• Operation time: 300 hours<br />

• Dimensions: 60x36x18 mm<br />

ECO series reflexion linear detector<br />

ES50 cod. SD8P00123<br />

Infrared ray linear smoke detector, for flush-mounting, working range: 50m<br />

• Consisting of ECO transmitting and receiving units and reflector with<br />

articulated joint<br />

• EN 54 certified - part 12 N. 0786-CPD-20214<br />

• Operating voltage: 12Vdc to 24Vdc<br />

• Outputs: alarm relay 1A@30Vdc<br />

• Optical failure relay 170mA@30Vcc<br />

• Working temperature: - 20° + 50°C<br />

• Protection: IP44<br />

• Dimensions: 103 (H) x 103 (L) x 63 (D) mm<br />

ES80 cod. SD9R00123<br />

Same as ES50 but with 80 m range.<br />

KATA cod. IL7500123<br />

Reflexion unit<br />

DETECTORS AND CONTROL UNITS<br />

SSM cod. SP7600123<br />

Pair of articulated joints for TX and reflector for the detectors of ECO<br />

series.<br />

INT8C/24V<br />

ADM<br />

ES50<br />

KATA<br />

61


ASPIRATING SYSTEMS<br />

DETECTORS AND CONTROL UNITS<br />

ASD cod. SC2R00123<br />

Aspirating single-pipe sampling unit.<br />

• For PVC/ABS ø 3/4” pipe, max pipe length: 100 m. Power supply: 24Vdc,<br />

smoke detectors not included.<br />

PICO cod. SC3R00123<br />

Laser aspiration smoke detector, single-pipe.<br />

• For PVC/ABS ø 3/4” pipe, max length: 100 m. Power supply: 24Vdc.<br />

<strong>FIRE</strong> TRACER cod. SC4R00123<br />

Fire Tracer with 4 aspirating pipes, 1 detection zone.<br />

• For 4 aspirating pipes PVC/ABS ø 3/4” pipe sections, 50m each. Power<br />

supply: 24Vdc, complete with diaphragm/ device control, event display.<br />

PLEASE CONTACT THE SALE NETWORK FOR ACCESSORIES<br />

ACCESSORIES FOR DETECTORS CHECK<br />

AST cod. AT7100123<br />

Fibreglass telescopic extension pole 6 m max<br />

DFS cod. RT7100123<br />

Smoke detector tester.<br />

• (DBS bottle required)<br />

DBS cod. SD9H10123<br />

Smoke detector test bottle.<br />

DTS cod. RT7200123<br />

Heat detector tester.<br />

DRS cod. SD8H10123<br />

Universal tool for removing and refitting any type of detectors<br />

62<br />

ASD<br />

<strong>FIRE</strong> TRACER<br />

DRS<br />

DFS


OPTICAL-<br />

ACOUSTIC<br />

INDICATORS<br />

POWER SUPPLY<br />

BATTERIES<br />

PANELS .................................... pag. 64<br />

OPTIC REPEATER ......................... pag. 66<br />

BELLS ....................................... pag. 67<br />

SOUNDERS ............................... pag. 68<br />

ELECTROMAGNETS .................... pag. 68<br />

EXPLOSION PROOF DEVICES ..... pag. 69<br />

POWER SUPPLY/BATTERIES ...... pag. 70<br />

63


PANELS<br />

Optical Acoustic Panels<br />

OPTICAL-ACOUSTIC INDICATORS<br />

TM24 cod. FH2600121<br />

• Optical/acoustic signalling single face panel<br />

• Power supply : 12 – 24 Vdc<br />

• Max consumption: 100 mA<br />

• Lighting by high efficiency leds<br />

• Buzzer sound pressure: 85dB at 1m<br />

• Steady/flashing light, selectable<br />

• Continuous/intermittent sound, selectable<br />

• Protection against polarity reverse<br />

• Working temperature: -10°C ÷ + 50°C<br />

• Material: self-extinguishing ABS, class V0<br />

• Protection: IP 40<br />

• The following pictographs are available as standard: Fire alarm, Withdraw<br />

from premises, Extinguishing in progress, Gas alarm, Fire alarm.<br />

TB24 cod. FH2700121<br />

Optical/acoustic signalling double face panel<br />

• Power supply : 12 – 24 Vdc<br />

• Max consumption: 100 mA<br />

• Lighting by high efficiency leds<br />

• Buzzer sound pressure: 85dB at 1m<br />

• Steady/flashing light, selectable<br />

• Continuous/intermittent sound, selectable<br />

• Protection against polarity reverse<br />

• Working temperature: -10°C ÷ + 50°C<br />

• Material: self-extinguishing ABS, class V0<br />

• Protection: IP 40<br />

• The following pictographs are available as standard: Fire alarm, Withdraw<br />

from premises, Extinguishing in progress, Gas alarm, Fire alarm.<br />

SPTB cod. SF5000121<br />

Bracket for optical/acoustic signalling double face panel TB24<br />

TM220 cod. FH2800121<br />

230Vac self-powered optical/acoustic signalling single face panel<br />

• Power supply : 230Vac<br />

• Max consumption: 100 mA<br />

• Lighting by high efficiency leds<br />

• Buzzer sound pressure: 85dB at 1m<br />

• Steady/flashing light, selectable<br />

• Continuous/intermittent sound, selectable<br />

• Protection against polarity reverse<br />

• Buffer battery: 3.6 V 1.5Ah Ni-Cd<br />

• Alarm endurance: 1 hour<br />

• Working temperature: -10°C ÷ + 50°C<br />

• Material: self-extinguishing ABS, class V0<br />

• Protection: IP 40<br />

• The following pictographs are available as standard: Fire alarm, Withdraw<br />

from premises, Extinguishing in progress, Gas alarm, Fire alarm.<br />

64<br />

TM24<br />

TB24<br />

TM220


PANELS<br />

Optical Acoustic Panels<br />

OPTICAL-ACOUSTIC INDICATORS<br />

TM224 cod. FH3100121<br />

24Vdc self-powered optical/acoustic signalling double face panel<br />

• Power supply : 24Vdc<br />

• Max consumption: 100 mA<br />

• Lighting by high efficiency leds<br />

• Buzzer sound pressure: 85dB at 1m<br />

• Steady/flashing light, selectable<br />

• Continuous/intermittent sound, selectable<br />

• Protection against polarity reverse<br />

• Buffer battery: 3.6 V 1.5Ah Ni-Cd<br />

• Alarm endurance: 1 hour<br />

• Working temperature: -10°C ÷ + 50°C<br />

• Material: self-extinguishing ABS, class V0<br />

• Protection: IP 40<br />

• The following pictographs are available as standard: Fire alarm, Withdraw<br />

from premises, Extinguishing in progress, Gas alarm, Fire alarm.<br />

TMSV cod. FH5400121<br />

Single-face optical/sound plate with speech synthesizer<br />

• Power supply: 24Vdc<br />

• Absorption: 180 mA<br />

• 8 pre-recorded messages<br />

• 3 voice alarm zones<br />

• free combination of pre-recorded messages<br />

• 1 customized message<br />

• 4 operating modes: SPEECH - SOUND - SOUND + SPEECH - SPEECH +<br />

SOUND<br />

• Dimensions (L) x (H) x (D) mm: 365 x 180 x 50<br />

TM224<br />

TMSV<br />

65


VISUAL REPEATERS<br />

Outdoor visual repeaters<br />

OPTICAL-ACOUSTIC INDICATORS<br />

LR500 cod. SR1100121<br />

Outdoor visual repeater<br />

• Visual repeater allowing to show the alarm status of a detector installed<br />

in hidden spaces. Suitable for all ELKRON detectors with ZB204 base or<br />

SD500R base.<br />

• Power supply: 12 – 24Vdc<br />

• Absorption: 11 mA<br />

• Terminal connection<br />

• Working temperature: -10°C ÷ + 55°C<br />

• Weight: 30 g<br />

• Protection: IP40<br />

• Case material: ABS, class VO<br />

• 2 high efficiency red leds<br />

• Steady/flashing light, selectable<br />

• Dimensions: 65.5 (L) x 60.6 (H) x 23.6 (D) mm<br />

LR500SI cod. SR1200121<br />

Outdoor visual repeater for FAP500 digital systems<br />

• Visual repeater allowing to show the alarm status of a detector installed in<br />

hidden spaces and to indicate detector regular operation (green led flashing).<br />

Suitable for all ELKRON detectors with SD500R base. This repeater can only<br />

be used with FAP500 detectors.<br />

• Power supply: 12 – 24Vdc<br />

• Absorption: 11 mA<br />

• Terminal connection<br />

• Working temperature: -10°C ÷ + 55°C<br />

• Weight: 30 g<br />

• Protection: IP40<br />

• Case material: ABS, class VO<br />

• 2 high efficiency white leds<br />

• 1 high efficiency green led<br />

• Steady/flashing light, selectable<br />

• Dimensions: 65.5 (L) x 60.6 (H) x 23.6 (D) mm<br />

66<br />

LR500<br />

LR500SI


ELECTRONIC BELLS<br />

Bells<br />

4476/24 cod. HS7300123<br />

Bell with classic appearance for fire alarm systems and other warnings.<br />

• The internal movement with motor, pinion and striker, jointly with the external<br />

bell in steel produces a powerful sound with a low current consumption.<br />

• Power supply: 24 Vdc<br />

• Average absorption: 25 mA<br />

• Sound pressure at 1 metre distance: 93/95 dB<br />

• Operation temperature: -10°C ÷ +50°C<br />

• Protection degree: IP 42<br />

4460/24 cod. HS1700123<br />

Electronic bell with sophisticated appearance and innovative technology fully<br />

covered with polyurethane resin ensuring high protection and resistance<br />

degree.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

Maximum control of sound signal through 28 tones that can be selected<br />

during installation by 5 internal dip-switches and through volume control by<br />

trimmer.<br />

Installation is made simple by siren bayonet joint on siren base and by double<br />

pins allowing to shunt connections.<br />

Enclosure material: Thermoplastic body, red colour<br />

Power supply: 24 Vdc<br />

Average absorption: 16 mA<br />

Sound pressure at 1 metre distance: 102 dB<br />

Operation temperature: -10°C ÷ +70°C<br />

Protection degree: IP 54<br />

4479/24 cod. HS7200123<br />

Electronic bell with sophisticated appearance and innovative technology for<br />

fire alarm systems and other warnings.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

Combining a miniaturised solenoid to a built-in control circuit, excellent<br />

acoustic performance, minimum current consumption and high reliability are<br />

allowed.<br />

Power supply doubled pins and cap latching make the bell particularly easy<br />

to be installed.<br />

IP 55 protection degree allows bell outdoor use; however, the bell can also be<br />

mounted in indoor environments.<br />

Power supply: 24 Vdc<br />

Average absorption: 30 mA<br />

Operation temperature: -10°C ÷ +55°C<br />

Sound pressure at 1 metre distance: 93-95 dB<br />

Protection degree: IP 55<br />

3465/24 cod. HS1900123<br />

Piezoelectric sounder for indoor with xenon lamp<br />

• Power Supply: 24Vcc.<br />

• Absorption: 170 mA.<br />

• Sound pressure at 1 m: 110 dB.<br />

• Colour: red.<br />

OPTICAL-ACOUSTIC INDICATORS<br />

4476/24<br />

4460/24<br />

4479/24<br />

3465/24<br />

67


SOUNDERS<br />

OPTICAL-ACOUSTIC INDICATORS<br />

HP500F cod. HS5000121<br />

Outdoor red self-powered siren made in die-cast aluminium.<br />

Provided with signalling flash with incandescent lamp.<br />

• Operation voltage: 24 Vdc<br />

• Protection degree: IP 43<br />

• Sound pressure: 104 dB (A) at 3 mt distance<br />

• Operation temperature: -25° C / +55° C<br />

• Assignable accumulator: 12 V 2,1 Ah<br />

• Dimensions (hxlxd): 265x210x65 mm.<br />

DSE/626 cod. HS2100123<br />

Red siren for premises evacuation in compliance with with regulation<br />

626/94. Two-tone alarm, xenon visual signalling.<br />

• Operation voltage: 230 Vac<br />

• Protection degree: IP 44<br />

• Sound pressure: 104 dB (A) at 3 mt distance<br />

• Operation temperature: -25° C / +55° C<br />

• Assignable accumulator: 12 V 2,1 Ah<br />

• Dimensions (hxlxd): 265x210x65 mm<br />

• Weight: 2,1 Kg.<br />

ELECTROMAGNETS<br />

Electromagnetic Stop<br />

1370/15 cod. MM7100123<br />

Electromagnetic stop implemented in order to keep open fire or transit doors<br />

and release them in case of fire.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

The magnet has two mounting positions on magnet body and, by bracket<br />

provided (15 cm bracket), allows the stop to be installed both as a wall stop<br />

and as a floor stop. Complete with unlocking pushbutton. It is available a<br />

model with 30 cm bracket with code MM7300123.<br />

Hooking force: 50 kg, actual<br />

Working voltage: 24 Vdc<br />

Absorption: 65 mA<br />

Operation temperature: -10 °C to + 55 C°<br />

Weight: 1,2 Kg<br />

1370/30 cod. MM7300123<br />

Same as 1370/15 with 30cm bracket.<br />

EM50P cod. MM7000123<br />

Door holder electromagnet with release button. Power 24 Vdc. Holding<br />

force 50 Kg.<br />

EM100P cod. MM9000123<br />

Door holder electromagnet with release button. Power 24 Vdc. Holding<br />

force 100 Kg.<br />

68<br />

HP500F<br />

DSE/626<br />

1370/15


EXPLOSION PROOF DEVICES<br />

EXPLOSION PROOF<br />

DEVICES<br />

BUTTON<br />

P/406 cod. SB3000121<br />

Manual fire alarm pushbutton, with explosion-proof casing, for areas with<br />

potentially explosive atmosphere.<br />

• Emergency break glass hammer provided as standard. Pushbutton in diecast<br />

material, red epoxy paint.<br />

• Holes for cables: 2x3/4 gas thread.<br />

• Classification: II 2GD EEx d IIB T6, EEx d IIB+H2 T6.<br />

• Certification: CESI 03 ATEX 050.<br />

• Working temperature: –20°C/+50°C.<br />

• Weight: 1.1 Kg.<br />

OPTICAL-ACOUSTIC INDICATORS<br />

T/800 cod. FH3500121<br />

The optical/acoustic system includes the body of siren T/800S and the body<br />

of visual repeater T/800L. These shells are made of a casting of cast iron<br />

G-20 uni 5007. The two bodies are connected to each other.<br />

• Working voltage: 27 Vdc<br />

• Alarm absorption: 180 mA<br />

• Weight: 3 kg<br />

T/800S cod. HS1800121<br />

Siren made of a casting of cast iron G-20 uni 5007 with a diffusing cone of<br />

plastic material (ABS); inside the body there is placed an electronic circuit<br />

for acoustic activation.<br />

• Working voltage: 27 Vdc<br />

• Alarm absorption: 180 mA<br />

• Sound level: 60 db at 1 mt at 24 V<br />

• Protection degree: IP 65<br />

• Weight: 3 kg<br />

T/800L cod. SR0200121<br />

Visual repeater made up of a shell made of a casting of cast iron G-20 uni<br />

5007. The body of the visual repeater is provided with a gem on cover cap<br />

of unbreakable (polycarbonate) material.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

Inside the body there are placed a bakelite lamp holder and a 30 Volt 5<br />

Watt lamp; on the lamp holder there are arranged the pins for connecting<br />

repeater activation system.<br />

Working voltage: 10,5 to 36 Vdc<br />

Alarm absorption: 200 mA<br />

Protection degree: IP 65<br />

Weight: 3 kg<br />

P/406<br />

T/800<br />

T/800S<br />

T/800L<br />

69


POWER SUPPLY UNITS AND BATTERIES<br />

POWER SUPPLY UNITS<br />

AND BATTERIES<br />

POWER SUPPLY UNITS<br />

82425 SBG cod. PS7900123<br />

Power supplier with 27.6 V output voltage in switching version and current 2.5 A.<br />

• High protection degree against overload, polarity inversions, short circuit.<br />

Power supplier status is signalled by 4 external leds: network in (Green) led,<br />

battery charger functionality (Green) led, battery down (Red) led, failure (Red)<br />

led. Provided with key for opening and closing the front lid.<br />

• Primary power supply: 230 Vac<br />

• Protection degree: IP 30<br />

• Operation temperature: +5 °C to +40 °C<br />

• EN 54-4 certified<br />

82450 BG cod. PS8000123<br />

Power supplier with 27.6 V output voltage in switching version and current 5 A<br />

• High protection degree against overload, polarity inversions, short circuit.<br />

Power supplier status is signalled by 4 external leds: network in (Green) led,<br />

battery charger functionality (Green) led, battery down (Red) led, failure (Red)<br />

led. Provided with key for opening and closing the front lid.<br />

• Primary power supply: 230 Vac<br />

• Protection degree: IP 30<br />

• Operation temperature: +5 °C to +40 °C<br />

• EN 54-4 certified<br />

BATTERIES<br />

RB06 cod. RB0410113<br />

12 V 7,2 Ah Water Proof rechargeable battery<br />

RB12 cod. RB0210113<br />

6 V 1,3 Ah Water Proof rechargeable battery.<br />

RB 19 cod. RB0310113<br />

12 V 2,2 Ah Water Proof rechargeable battery.<br />

RB 15 cod. RB0810113<br />

12 V 18 Ah Water Proof rechargeable battery.<br />

RB 24 cod. RB0510113<br />

12 V 26 Ah Water Proof rechargeable battery.<br />

RB 612 cod. RB0910113<br />

6 V 12 Ah Water Proof rechargeable battery.<br />

RB 1212 cod. RB1110113<br />

12 V 12 Ah Water Proof rechargeable battery.<br />

70

Hooray! Your file is uploaded and ready to be published.