In order for the annunciators to activate, the displayed value must be at least fivegraduations above zero.Fill StatusFast FillDribble Fill (or Single-Speed Fill)Fill Done or PauseAnnunciator StatusSP 1 & SP 2 IlluminatedSP 1 IlluminatedSP 1 & SP 2 OffFill ExampleWith a system set up to fill 55-gallon drums with motor oil, the following settings mightbe used to achieve an accurate final fill weight of 400 lbs.:ParameterSettingActual Cutoff ValueCommentsTarg 1 = 400Desired final weight.Pre-act 1 = 28 400 - 28 = 372.0 Switch to dribble feed at 372.Pre-act 2 = .5 400 - 0.5 = 399.5 Final fill valve closes at 399.5.4.19 BatchThe standard batch program is used for batching up to three separate items.Ingredients 1 through 3 use setpoints and pre-acts 1 through 3 respectively. Ingredientsare batched one at a time. Free falling product can be accounted for with the use ofpre-act values (PA1 - PA3). This feature must be enabled before attempting to use.SetpointSelectionFunctionDescriptionP5100.3 Batch 2 or 3 ingredient batching.P5101.-- Targ1 Ingredient 1 target value.P5104.0 Based Select from net or count (quantity).P5105.-- PA 1 Pre-act 1 value (final cutoff for ingredient 1).P5106.1 Learn 1 Learn feature for pre-act 1 enabled.P5107.0 Start 1 Setpoint 1 activation method.P5108.-- Targ 2 Ingredient 2 target value.P5109.-- PA 2 Pre-act 2 value (final cutoff for ingredient 2).P5110.1 Learn 2 Learn feature for pre-act 2 enabled.P5111.0 Start 2 Setpoint 2 activation method.P5116.1 Pause Keypad press invokes pause mode.P5117.-- Targ 3 Ingredient 3 target value.P5118.-- PrAc 3 Pre-act 3 value (final cutoff for ingredient 3).P5119.1 Learn 3 Learn feature for pre-act 3 enabled.P5120.0 Start 3 Setpoint 3 activation method.84Model 350 I.S. and Model 355 I.S. Service Manual

4.19.1 Enter a TargetPressing [TARE] or [ENTER] alone allows access to the subsets. PA1 and PA2 are thesubsets for Targ 1.Model 350 I.S.1. Press [SELECT] until tArG1 is displayed.2. Press [PRINT] until the first digit of the new target is displayed. Press [UNITS]to accept the number displayed. Continue this step until the desired number isentered.Example: Target of 202a. Press [PRINT] four timesDISPLAY READS> 22b. Press [UNITS] to accept the 2 that is displayedDISPLAY READS> 2 .2c. Press [PRINT] onceDISPLAY READS> 202d. Press [TARE] to accept the target weight as 20DISPLAY READS> 203. Press [TARE]. Once the tare key is pressed, it is possible that PA1 will bedisplayed if the pre-act parameter is enabled.3a. If a value is desired, enter it in the same manner as the target weight wasentered above. When the displayed value is correct, press [TARE].3b. If no value is to be entered or PA1 is not displayed, press [TARE] to go to thenext screen.4. Repeat steps 2 and 3 until all targets and pre-acts are entered. Press [TARE]to return to the weigh mode.Model 355 I.S.1. Press [SELECT] until tArG1 is displayed.2. Key in the desired target value with the numeric keys and press [ENTER].3. The PA1 value will be displayed. Key the in value with the numeric keys andpress [ENTER].4. Repeat steps 2 and 3 for tArG2, PA2, tArG3 and PA3.5. Press [SELECT] to select the desired weigh mode parameter.Model 350 I.S. and Model 355 I.S. Service Manual 85

In order for the annunciators to activate, the displayed value must be at least fivegraduations above zero.Fill StatusFast FillDribble Fill (or Single-Speed Fill)Fill Done or PauseAnnunciator StatusSP 1 & SP 2 IlluminatedSP 1 IlluminatedSP 1 & SP 2 OffFill ExampleWith a system set up to fill 55-gallon drums with motor oil, the following settings mightbe used to achieve an accurate final fill weight of 400 lbs.:ParameterSettingActual Cutoff ValueCommentsTarg 1 = 400Desired final weight.Pre-act 1 = 28 400 - 28 = 372.0 Switch to dribble feed at 372.Pre-act 2 = .5 400 - 0.5 = 399.5 Final fill valve closes at 399.5.4.19 BatchThe standard batch program is used for batching up to three separate items.Ingredients 1 through 3 use setpoints and pre-acts 1 through 3 respectively. Ingredientsare batched one at a time. Free falling product can be accounted for with the use ofpre-act values (PA1 - PA3). This feature must be enabled before attempting to use.SetpointSelectionFunctionDescriptionP5100.3 Batch 2 or 3 ingredient batching.P5101.-- Targ1 Ingredient 1 target value.P5104.0 Based Select from net or count (quantity).P5105.-- PA 1 Pre-act 1 value (final cutoff for ingredient 1).P5106.1 Learn 1 Learn feature for pre-act 1 enabled.P5107.0 Start 1 Setpoint 1 activation method.P5108.-- Targ 2 Ingredient 2 target value.P5109.-- PA 2 Pre-act 2 value (final cutoff for ingredient 2).P5110.1 Learn 2 Learn feature for pre-act 2 enabled.P5111.0 Start 2 Setpoint 2 activation method.P5116.1 Pause Keypad press invokes pause mode.P5117.-- Targ 3 Ingredient 3 target value.P5118.-- PrAc 3 Pre-act 3 value (final cutoff for ingredient 3).P5119.1 Learn 3 Learn feature for pre-act 3 enabled.P5120.0 Start 3 Setpoint 3 activation method.84Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!