4.18 FillThe fill program is used for single-speed or dual-speed filling operations. The dualspeedfill operation allows for both a fast and a slow fill mode. During a fast-fill,setpoints 1 (SP1) and 2 (SP2) are activated. During a slow-fill or single-speed fill, onlysetpoint 1 (SP1) is activated. This feature must be enabled before attempting to use.Over filling can be prevented with the use of pre-act values (PA1 and PA2). Pre-act 1(PA1) is used for switching the fast fill to a slow fill. Pre-act 2 (PA2) is used as a finalcutoff value.SetpointSelectionFunctionDescriptionP5100.1 Fill Select Fill Setpoint OperationP5101.-- Targ1 Final Fill Target ValueP5104.0 Based Select between Net or QuantityP5105.-- PA 1 Pre-Act 1 Value (Fast-to-Slow Value; 0 for Single-Speed)P5107.0 Start 1 Setpoint Activation MethodP5109.-- PA 2 Pre-Act 2 Value (Final Cutoff)P5110.1 Learn 2 Learn Feature for Pre-Act 2P5114.1 PrAc 1 Pre-Act 1 Available as Subset in Weigh ModeP5115.1 PrAc 2 Pre-Act 2 Available as Subset in Weigh ModeP5116.1 Pause Keypad Press invokes Pause4.18.1 Enter a Target ValuePressing [TARE] or [ENTER] alone allows access to the subsets. PA1 and PA2 are thesubsets for Targ 1.Model 350 I.S.1. Press [SELECT] until tArG1 is displayed.2. Press [PRINT] until the first digit of the new target is displayed. Press [UNITS]to accept the number displayed. Continue this step until the desired number isentered. Refer to the example below.Example: Target of 202a. Press [PRINT] four timesDISPLAY READS> 22b. Press [UNITS] to accept the 2 that is displayedDISPLAY READS> 2 .2c. Press [PRINT] onceDISPLAY READS> 202d. Press [TARE] to accept the target weight as 20DISPLAY READS> 2082Model 350 I.S. and Model 355 I.S. Service Manual
3. Press [TARE]. Once the tare key is pressed, it is possible that PA1 will bedisplayed if the pre-act parameter is enabled.3a. If a value is desired, enter it in the same manner as the target weight wasentered above. When the displayed value is correct, press [TARE].3b. If no value is to be entered or PA1 is not displayed, press [TARE] to go to thenext screen.4. If PA2 is displayed, enter the value in the same manner as the target weightwas entered above and press [TARE] to accept or press [TARE] to return tothe weigh mode. Press [SELECT] to view the desired weigh mode parameter.Model 355 I.S.1. Press [SELECT] until tArG1 is displayed.2. Key in the desired target value with the numeric keys and press [ENTER].3. The PA1 value will be displayed. Key the in value with the numeric keys andpress [ENTER].4. The PA2 value will be displayed. Key the in value with the numeric keys andpress [ENTER].5. Press [SELECT] to select the desired weigh mode parameter.4.18.2 Start FillActivation MethodThe fill begins with the selected activation method. The method is determined by theparameters in the setup mode.The deactivation of the setpoints is automatic. The desired target may be based on netor quantity (if counting is enabled).Activation typeslllTare key - Press the [TARE] key to start the process. A tare weight will be setand the weight will switch to net zero.Remote key - Press the remote key switch.Auto-start - The process is automatically activated. It waits for a no-motioncondition and then adds the target to the current displayed weight to achievea relative cutoff value.AnnunciatorsIndication on the display showing the status of a relay. If the annunciator is illuminated,the corresponding setpoint is activeModel 350 I.S. and Model 355 I.S. Service Manual 83
- Page 33 and 34: 3 InstallationThe Model 350/355 I.S
- Page 35 and 36: 3.2.2 Model 355 I.S.Figure 3.3 Mode
- Page 37 and 38: 3.5 Remote Key ConnectionsThe Model
- Page 39 and 40: Battery ChargingTHE BATTERY MUST BE
- Page 41 and 42: 3. Snap the (4) ½ plastic standoff
- Page 43 and 44: Figure 3.12 Fiber-optic Cable Insta
- Page 45 and 46: Install the setpoint or Analog opti
- Page 47 and 48: 3.8.5 Safe Area Analog Option Insta
- Page 49 and 50: 4 ConfigurationThis section covers
- Page 51 and 52: To access the previous parameter1.
- Page 53 and 54: To setup a full scale value (exampl
- Page 55 and 56: 4.5.2 Return to factory default (35
- Page 57 and 58: ParameterNumberDisplayNameP296.00 E
- Page 59 and 60: P115 Stability Delay (Selection)Sel
- Page 61 and 62: P204 Comm Handshake (Comm 1) (Selec
- Page 63 and 64: P292 End Character (Key-in)Set the
- Page 65 and 66: P802 Tare and Zero Execution (Selec
- Page 67 and 68: is an 'O' (overload/underload), 'M'
- Page 69 and 70: 4.9 ID Number Entry and PrintingIt
- Page 71 and 72: 4.10.4 Entering ASCII Control Codes
- Page 73 and 74: The default format code for all par
- Page 75 and 76: 4.12.2 Model 355 I.S.To sample usin
- Page 77 and 78: 4.14 Remote Key ConfigurationThe Mo
- Page 79 and 80: 4.16 Setpoint SetupThe Model 350/35
- Page 81 and 82: Pre-act values are entered in terms
- Page 83: 4. Next the PctHi value will be dis
- Page 87 and 88: 4.19.1 Enter a TargetPressing [TARE
- Page 89 and 90: ParameterSettingPre-Act 2 = 236 15,
- Page 91 and 92: 4.20.3 Start DischargeActivation Me
- Page 93 and 94: 3a. If a value is desired, enter it
- Page 95 and 96: 4.22 Absolute CheckweighThis progra
- Page 97 and 98: 4.23 Target Deviation CheckweighThe
- Page 99 and 100: 4.24 Batch 2The batch 2 program is
- Page 101 and 102: 4.25 Independent Setpoint Operation
- Page 103 and 104: 4.25.3 ExampleSetup a continuous-cy
- Page 105 and 106: Bars ON Weight Range (Lower Toleran
- Page 107 and 108: ParameterSettingDisplayedNameDescri
- Page 109 and 110: 4.27.2 Analog Output ExampleAnalogP
- Page 111 and 112: 4.28.2 Setup Master IndicatorSet th
- Page 113 and 114: ParameterSettingDisplayedNameDescri
- Page 115 and 116: Custom Transmit :1. [.002] [ENTER]
- Page 117 and 118: 4.28.5 300 Series Command CodesHex
- Page 119 and 120: 5 CalibrationThis chapter covers al
- Page 121 and 122: First Zero Calibration Method (355
- Page 123 and 124: 9. Pause for motion delay.10. Press
- Page 125 and 126: 13. Pause for motion delay.14. Pres
- Page 127 and 128: If the calibration weight value was
- Page 129 and 130: 6 Legal for TradeThe Model 350/355
- Page 131 and 132: 6.4.1 Physical SealThe most common
- Page 133 and 134: 7 TroubleshootingThis chapter conta
4.18 FillThe fill program is used for single-speed or dual-speed filling operations. The dualspeedfill operation allows for both a fast and a slow fill mode. During a fast-fill,setpoints 1 (SP1) and 2 (SP2) are activated. During a slow-fill or single-speed fill, onlysetpoint 1 (SP1) is activated. This feature must be enabled before attempting to use.Over filling can be prevented with the use of pre-act values (PA1 and PA2). Pre-act 1(PA1) is used for switching the fast fill to a slow fill. Pre-act 2 (PA2) is used as a finalcutoff value.SetpointSelectionFunctionDescriptionP5100.1 Fill Select Fill Setpoint OperationP5101.-- Targ1 Final Fill Target ValueP5104.0 Based Select between Net or QuantityP5105.-- PA 1 Pre-Act 1 Value (Fast-to-Slow Value; 0 for Single-Speed)P5107.0 Start 1 Setpoint Activation MethodP5109.-- PA 2 Pre-Act 2 Value (Final Cutoff)P5110.1 Learn 2 Learn Feature for Pre-Act 2P5114.1 PrAc 1 Pre-Act 1 Available as Subset in <strong>Weigh</strong> ModeP5115.1 PrAc 2 Pre-Act 2 Available as Subset in <strong>Weigh</strong> ModeP5116.1 Pause Keypad Press invokes Pause4.18.1 Enter a Target ValuePressing [TARE] or [ENTER] alone allows access to the subsets. PA1 and PA2 are thesubsets for Targ 1.Model 350 I.S.1. Press [SELECT] until tArG1 is displayed.2. Press [PRINT] until the first digit of the new target is displayed. Press [UNITS]to accept the number displayed. Continue this step until the desired number isentered. Refer to the example below.Example: Target of 202a. Press [PRINT] four timesDISPLAY READS> 22b. Press [UNITS] to accept the 2 that is displayedDISPLAY READS> 2 .2c. Press [PRINT] onceDISPLAY READS> 202d. Press [TARE] to accept the target weight as 20DISPLAY READS> 2082Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong>