11.07.2015 Views

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

The default format code for all parameters is 0. This prints all numeric data with 8characters, right justified, left spaces filled, the units (if applicable) and the parametername. The format choices for all parameters (except Stability Status and SetpointStatus) are shown in the following table.Choice Sample Print Result Description<strong>Weigh</strong>t Parameter Format Codes0 " 27.49 lb Gross" Fixed width (8 characters), right justified, leftspaces filled.1 "000027.49 lb Gross" Fixed width (8 characters), right justified, leftzeroes filled.2 "27.49 lb Gross" Fixed width, left justified, right spaces filled.3 "27.49 lb Gross" Minimum possible width.8 "400. lb Net" Print decimal point, even if data has nofractional portion.16 "+400 lb Net" Print "+" for positive numbers.32 "336.52 Net" Do NOT print parameter units (lb or kg).64 "336.52 lb Net" Print value in "default" units (as opposed tocurrent viewed units).128 "336.52 lb" Do NOT print parameter name.Only Format Code that applies to IDTime / Date Format Codes1 "10:07:40 am 10/26/09 Includes seconds with time.2 "10:08 10/26/09" 24 hour time format.4 "10:11 am Oct 26, 2009" Print date spelled out.8 "10:12 am Fri 01/26/01" Print day of the week.16 "10:12 am 26/10/09" International date format.32 "980503984 Tm/Dt" # of seconds since 12:00 AM Jan 1, 1970.64 "10/26/09" Do NOT print time.128 "10:14 am" Do NOT print date.4.11.1 Exiting Setup Mode and Saving ChangesEach custom transmit file must end with:%z%c%e%eThis exits the Setup Mode, bypasses the calibration procedure and saves the indicatorconfiguration file.4.12 Parts CountingThe counting parameter must be enabled before using. Follow the instructions belowfor sampling and counting parts. A new sample must be performed for each unique partbeing counted. The indicator will not store the average piece weight.Parameter (P170) must be enabled before parts counting is accessible. See page 48for details on selecting a specific parameter.Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong> 71

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!