4.11 Parameter Selection NumbersThe following sequence enters parameters into a custom transmit: %e, the parameternumber, %e%e , a format code, and then %e%e with no intervening spaces.%e 0 %e%e 0 %e%eInitiates ParameterEntryParameter NumberEnters Parameterand InitiatesFormat EntryFormat ChoiceEnters Formatand Ends EntryParameter NameParameterNumberSample Print OutputGross <strong>Weigh</strong>t 0 27.49 lb GrossNet <strong>Weigh</strong>t 1 14.53 lb NetTare <strong>Weigh</strong>t 2 12.96 lb TareTime / Date 11 10:01:01 am 01/26/01ID 21 ID: 12MN53Quantity 30 58 QtyAPW 34 0.25 lb APWAPW * K 35 250 lb APW * KTarg1 60 400 lb Targ1Targ2 64 500 lb Targ2Targ3 66 1000 lb Targ3Act 1 (note: Indp. SP1) 70 600 lb Act 1Rst 1 (note: Indp. SP1) 71 10 lb Rst 1Act 2 (note: Indp. SP2) 72 300 lb Act 2Rst 2 (note: Indp. SP2) 73 10 lb Rst 2Act 3 (note: Indp. SP3) 74 100 lb Act 3Rst 3 (note: Indp. SP3) 75 5 lb Rst 3Setpoint Status 96 Setpt 0Stability Status 97 Stat MDisplayed Value 98 16.34 lb GrossTable 4.2 Custom Transmit Parameter Selection Numbers70Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong>