GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...
GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...
GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
4.10.1 Writing A Custom Transmit ASCII Text FileAny text editor may be used to construct a custom transmit (Notepad, Wordpad,Communication Plus, etc.), but you must save the custom transmit as a text (.txt) file.Instructions can also be sent keystroke by keystroke from a communications program.To do so, ignore the Model 350/355 I.S. display and enter the characters in the correctorder. Figure 4.1 shows a custom transmit written in Wordpad.4.10.2 Access Setup and Clearing Existing Custom TransmitEvery custom transmit file must start with:1999%s%s%z%p%u%e%c%eThis accesses the Setup Mode at the end of the existing transmit and then clears thetransmit so that a new one may be entered.Figure 4.1 Custom Transmit File4.10.3 Entering ASCII TextASCII text is defined as printable characters, including alpha-numeric as well aspunctuation and symbols. See Table 4.1 for a complete listing of ASCII characters.ASCII text can be entered directly into a custom transmit with a %e (enter command).For example, Joe's Fertilizer Plant%e.68Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong>