11.07.2015 Views

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

P440 Legal for Trade Restrictions (Toggle)Enable NTEP legal-for-trade restrictions. See section 6.1for details.P500 Time Setting (key in)Enter the time in the form HH.MM.SS. Time is always shown in military format withinthis parameter. P503 will determine how the time is displayed in the weigh mode.P501 Date Setting (key in)Enter the date in the form MM.DD.YY. P504 will determine the how the date isdisplayed in the weigh mode.P502 Time/Date (toggle)Enables or disables the time and date feature. If enabled the time and date will beaccessible from the weigh mode with the [SELECT] key. The weight will continue to beupdated when viewing the time or date. The time will be formatted as defined by P503and the date will be formatted as defined by P504. See page 73 for instructions on howto change the time and/or date.P503 Hours (toggle)Determines the TIME format style, 12 hour or 24 hour. If in 12 hour mode the right mostdecimal point on the display will become the PM indicator. Note: The time must beentered as military time. If the mode is set for 12 hour, the time will be converted to a12 hour clock.P504 Style (toggle)Determines the DATE format style, U.S.A. or Int'l. If set for U.S.A, the date will resemble01/26/01. If set for international, the date will resemble 26/01/01.P505 Time/Date Select (toggle)Enables or disables the editing of time and date the weigh mode.P800 Remote Key 1 Operation (Selection)Select function for Remote Key closure. Choose from None, Print, Tare, Zero or Print/Tare. If a setpoint is configured to use the remote key as an activation method, then theP800 setting is over-ridden. The Remote Key Configuration section on page 75 detailsthe remote key operation. See Remote Key Connection on page 35 for remote keyelectrical connections.P801 Remote Key 2 Operation (Selection)Select function for Remote Key closure. Choose from None, Print, Tare, Zero or Print/Tare. If a setpoint is configured to use the remote key as an activation method, then theP801 setting is over-ridden. The Remote Key Operation section on page 75 details theremote key operation. See Remote Key Connection on page 35 for remote keyelectrical connections.62Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!