P292 End Character (Key-in)Set the end character for the master indicator. Choices are 0 - 255. Default value is 3(ETX). The choice must match the end character at P275 of the remote display (slave).A value of 0 means that a byte with the value 0 will be sent for the character. Avoidusing values of 17 or 19 when using software flow control. The values of 17 and 19 areXon and Xoff codes and could cause conflict.P296 Echo Style (Toggle)Set the style of indicator the display will be echoed to. The choices are 300 or 60. The300 choice is for 350, 355, 350 I.S., 355 I.S., 351, ABS 4100. Choose 60 for 460 series,560 series and 660 series indicators.P410 Euro (Toggle)Enable OIML legal-for-trade restrictions (see page 127).P412 Preset Character (Toggle)If P412 is enabled, it will add a 'P' to the beginning of the tare parameter on the displayand transmits if the last tare value was entered manually by the user (numeric entry).P167 needs to be enabled in order to key in a tare value. A 'P' will not be added if thelast tare was performed by pressing the tare key or if the tare value is zero (even if thezero value was manually entered by the user). The 'P' prefix stands for "Preset". WhenP412 is disabled, the unit will never show 'P' before tare no matter how tare is entered.P420 Display (Selection)Select display control option. Choose from On, Off or Auto. The auto setting helpsconserve power for extended battery life. When the indicator display is off, the loadcell(s) are still powered.If P420 is set to Off or selection 0, you can turn on the display by holding down the[ZERO] key upon power up. This does not set P420 to On; it only temporarily turns onthe large VFD display in order to allow you to see what you are entering.Choice Number Selection Name DescriptionP420.00 Off Shuts off the display.P420.01 On Normal display operation.P420.02 Auto Shuts off the display when weight has stabilizedwithin 6 divisions for 5 minutes. Pressing [ON] orchanging weight more than 6 divisions will re-enablethe display. NOTE: The display will turn back on ifdata is received via the RS-232 Port.P423 Back Light (on/off)Toggle the backlight on a Model 350/355 I.S. LCD.P427 Battery Option Automatic Shutdown (Selection)Select duration of time for auto shutdown. Choose from selections with the [TARE] key.Selections are off, 0.5, 1, 2, 3, 4, 5, 10, 15, 20, 25, 30, 35, 40, 45, and 60. The choicesare set in minutes.Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong> 61

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!