11.07.2015 Views

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ParameterNumberDisplayNameDefault ValueValid Range/ ChoicesP5004.00 Chec Auto Auto / Start(Toggle)P5010.00 SPAnn Enable Enable / Disable(Toggle)P5011.00 SPBar Disable Enable / Disable(Toggle)P5012.00 BarPc 50% 0 - 100(Key In)P5100.00 SetPt None None - Checb(9 Selections)ParameterDescriptionPageRestart Mode 63Setpoint Annunciators 63Bargraph Display 64Bargraph Scaling 64Setpoint Operation 644.7 Parameter Map DetailsP110 Full Scale Value (Key in)Denotes the full scale capacity. This value should not exceed the rated capacity of theweighing device.P111 Division Size (Selection)Indicates the count-by and decimal point. Pressing [ZERO] + [TARE] (Model 350 I.S.)or [CLR] (Model 355 I.S.) will automatically select the choice closest to 10,000 divisionswithout exceeding 10,000 divisions.P112 Zero Track Aperture (Selection)Set in terms of number of divisions. Zero tracking eliminates small weight deviations ator near zero. <strong>Weigh</strong>t deviations within the selected window that have been stable formore than one second are tracked off, maintaining a gross or net zero condition.The sum of weight values zeroed with auto zero tracking and [ZERO] cannot exceedthe allowable zero range (P118).To determine the proper setting in a counting application, divide the weight of thesmallest product counted by the division size (P111). Zero Track should be set to 0 (off)for most setpoint filling operations. This prevents tracking off any product trickle at thestart of a fill process.P114 Stability (Selection)Stability is defined as weight fluctuations within an aperture that can be regarded asbeing a stable weight. Deviations outside this aperture are considered motion, and themotion annunciator on the front panel will light accordingly. Once the scale settleswithin the stability aperture, the indicator will wait for a period of time specified by themotion delay (P115) before the indicator is considered stable.Print operations configured as motion delayed (P114) will not send the specified datauntil the weight reflects a stable reading as designated by this setting. Certain setpointoperations are also considered motion delayed and will not change states until a nomotioncondition exists.56Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!