Parameter Name Description62000 Dsply ~ Test 8.8.8.8.8.8. Display test. Press [TARE] or [ENTER] to illuminate all segments. Continuepressing [TARE] or [ENTER] to cycle through various patterns.62001 Spt 1 ~ Disbl Allows setpoint status to be changed by pressing [TARE] or [ENTER] while62002 Spt 2 ~ Disblviewing this parameter. Requires that setup was entered using the access code.62003 Spt 3 ~ Disbl62020 AdAnl Displays the voltage of the AC to DC power supply. Refer to P62021 if a batteryin used. This parameter will still show a voltage when battery powered. Thisvoltage reading will be slightly lower than what is display at P62021.62021 AdbAt Displays the voltage level on the battery when battery powered. Will show 0 ifAC powered.64000 Send ~ Setup Transmits all setup information out the communication port.64100 LnCnt ~ 0 Received setup line count.64101 ErCnt ~ 0 Received setup error count.64102 1stEr ~ None! Parameter of the first setup receive error.65001 Deflt ~ All Default All. Sets all parameters to factory default settings. Press [TARE] or[ENTER] to initiate default.65002 Deflt ~ -CAL Same as above, except calibration is retained.65020 Re- ~ Flash Used for firmware upgrade. If [ENTER] is pressed at P65020, the indicator'sdisplay will blank out and appear locked up. The only way to unlock thisparameter is via a computer and terminal window software (ie. CommunicationsPlus, Hyper terminal). See Upgrade Indicator Firmware on page 75 to upgradefirmware.To escape the firmware upgrade:1) Connect a computer to the serial port and use a terminal program such asCommPlus. Set the computer protocol to 9600,8,1,none.2) Power up the indicator and the reflash menu will show in the terminal window.3) Press the d key on the computer keyboard to quit the reflash process.4) The indicator will return to a usable state.7.4 A/D Calibration ProcedureThe Model 350/355 I.S. Analog-to-Digital Converter (A/D) is calibrated at the factory toensure a stable, linear response to the load cell signal. This calibration procedurecalculates critical values that are permanently stored in parameters P61110 - P61121.The A/D calibration should not be confused with the standard weight calibration. Itshould never be necessary to recalibrate the A/D. However, if the values stored atparameters P61110 - P61121 appear to be reset to 0.00000 and/or 1.00000, then A/Drecalibration is necessary. Contact Avery <strong>Weigh</strong>-Tronix or your local authorized Avery<strong>Weigh</strong>-Tronix distributor for more information on this procedure.136Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!