7.1.4 Calibration ErrorsCodeF.S. ~TooHiF.S. ~ TooLoAdd ~ Load!ReCal ~ ???Entry ~ ErrorDescriptionThe entered calibration weight will result in an over-capacity condition at full scale. Verify that the full scale(P110) and calibration weight value are correct.The entered calibration weight will result in a full scale input signal less than the minimum allowed. Verify thatthe full scale (P110) and entered weight value are correct.The calibration weight is less than 0.1% of capacity. More weight is required.Repeat the cal. procedure for accuracy. This prompt appears when the calibration weight is less than 5% ofcapacity, or when the A/D coarse gain is adjusted.An invalid entry was made.7.1.5 Communication ErrorsCodePar-ErBuf-ErBit-ErTrans~Hold1Trans~Hold2Error~BaudXDescriptionThe selected parity (P202) does not match that of the connected device.The receive buffers capacity was exceeded. This indicates a handshaking problem. Check P204 and verifyproper communication port connections.The stop bit of a received character did not occur when expected. Verify that protocol (P200 - P204) matchesthat of the connected device.Data transmission is inhibited due to a deasserted handshake on communication port 1. Press [ZERO] or[CLR] to abort transmission. Check P204. If in a Control and Hub configuration, press [ZERO] or [CLR] threetimes to clear the error.Data transmission is inhibited due to a deasserted handshake on communication port 2. Press [ZERO] or[CLR] to abort transmission. Check P204. Check P204. If in a Control and Hub configuration, press [ZERO] or[CLR] three times to clear the error.The X being either comm port 1 or comm. port 2. The baud rate selected is too high for the microprocessorrate. Either set the baud rate lower or change the microprocessor rate at P60090 higher.7.1.6 Miscellaneous ErrorsCodeT.X.YYYYDescriptionIf catastrophic errors occur in the software, a trap error may occur and freeze the display with addressinformation. (X = bank number and YYYY = the address of the trap error. Press any key five seconds afterviewing message to reboot the unit).7.2 Viewing Setup ParametersWhile troubleshooting it may be helpful to view the setup parameter selections. Thiscan be done using the procedure below (even with the internal program jumper in the"NO" position). Note that accessing the Setup Mode in this manner will not permitparameter changes.Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong> 133

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!