Custom Transmit :1. [.002] [ENTER] or [TARE] - 2. [.004] [ENTER] or [TARE] - 3. [.016] [ENTER] or [TARE] - 4. [.064] [ENTER] or [TARE] - 5. [ENTER] or [TARE], [1], [ENTER] or [TARE], [160], [ENTER] or [TARE] - 6. [.003] [ENTER] or [TARE] - 7. Save changes and exit the setup mode.ASCII Code 128 64 32 16 8 4 2 0Annunciator 1 Good2 Gross Net Qty Other kgAnnunciator 2 lb Spt 1 Spt 2 Spt 3 >0< MotionThe start character and end character can be any ASCII character 1 - 255. Refer toTable 4.5 for the annunciator codes to be entered in the custom transmit. Always use160 for the format code when entering a parameter.4.28.4 Hazardous Area to Safe Area ConfigurationIn order to use setpoints or analog output modules they must be located in the safearea. These modules will be installed in the safe area hub. Refer to Safe Area SetpointOption Installation or Safe Area Analog Option Installation on page 44 for optioninstallation instructions. The control indicator will be in the hazardous area and wherethe load cell(s) will be connected. The control and hub indicators will communicate viafiber optic cable. Refer to Fiber Optic Interface on page 38 for installation instructions.Use the following instructions to setup the control and hub indicators. Once a controlor hub indicator is chosen at P260, the protocol and interactive parameters areautomatically set up. See Table 4.5 for the default parameters of the control and hub.The setpoint and analog output parameters are only set in the control indicator (referto Setpoint Setup on page 77 or Analog Output Setup on page 101). The hub indicatorwill echo the control indicator.Make sure the controller and hub are connected with the fiber-optic kit and fiber-opticcable. Setup the hub indicator first and either cycle power or enter then exit the setupmode. This will synchronize P176, P177, P61200 - P61205.Simple Setup (Hub Indicator):1. Set P260 for Hub.2. Exit the setup mode.Simple Setup (Control Indicator):1. Set P260 for Cntrl.2. Exit the setup mode.Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong> 113

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!