11.07.2015 Views

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Display (P271)When set for Display, information will be displayed on the remote indicator exactly asit appears on the master indicator.Set P271 for Display and configure all other remote display parameters. Configure theparameters in the master indicator (refer to Setup Master Indicator on page 109). Makesure that the wiring connections between the master and remote indicators are correct(refer to Remote Display Connections on page 35).Custom (P271)When set for Custom, the master indicator will send customized information to bedisplayed on the remote indicator. A parameter or text data may be transmitted to theremote indicator on a continual or "on demand" basis.Set P271 for Custom and set all other remote display parameters (refer to Table 4.4).Configure the parameters in the master indicator (refer to Setup Master Indicator onpage 109). Make sure that the wiring connections between the master and remoteindicators are correct (refer to Remote Display Connections on page 35. Follow theinstructions below for configuring the master indicator.1. Turn echo off at P290.2. Set the transmit to be continuous at P210 (port 1) or P230 (port 2). This is theport going to the remote indicator.3. Program custom transmit in the master indicator at P1000 (port 1) or P2000(port 2). See the example below for instructions on programming a customtransmit.If time out is enabled (P270), then the transmit should be set for continuous at P210 orP230 and have stability disabled at P212 or P232Example:The master indicator will be active and the Net weight will be displayed on the remoteindicator. The net and lb annunciators will illuminate. The codes for the annunciatorswill be entered as they are control codes (see Entering ASCII Control Codes on page69. The address of the remote indicator at P272 is 4. If P272 is set to None!, do notenter anything for the address field.Access custom transmit 1 (P1000) or custom transmit 2 (P2000).Format String:If P274 and P275 = 1 - 255, , , , , orIf P274 or P275 = 0, , , , 112Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!