ParameterSettingDisplayedNameDescriptionP277.01 R-start Enables or disables the use of the [START] key on the master indicator. When thisparameter is enabled and the key is pressed, a start key command will berecognized by the master indicator. The Tx, Rx and GND line must be connectedbetween the COMM Ports of the master and remote unit. If this parameter isdisabled the [START] key will have no effect on the master indicator.P278.01 R-stop Enables or disables the use of the [STOP] key on the master indicator. When thisparameter is enabled and the key is pressed, a stop key command will berecognized by the master indicator. The Tx, Rx and GND line must be connectedbetween the COMM Ports of the master and remote unit. If this parameter isdisabled the [STOP] key will have no effect on the master indicator.P280.01 Zero Enables or disables the use of the [ZERO] key on the master indicator. When thisparameter is enabled and the key is pressed, a Zero key command will berecognized by the master indicator. The Tx, Rx and GND line must be connectedbetween the COMM Ports of the master and remote unit. If this parameter isdisabled the [ZERO] key will have no effect on the master indicator.P281.01 Units Enables or disables the use of the [UNITS] key on the master indicator. When thisparameter is enabled and the key is pressed, a Units key command will berecognized by the master indicator. The Tx, Rx and GND line must be connectedbetween the COMM Ports of the master and remote unit. If this parameter isdisabled the [UNITS] key will have no effect on the master indicator.P282.01 Select Enables or disables the use of the [SELECT] key on the master indicator. When thisparameter is enabled and the key is pressed, a Select key command will berecognized by the master indicator. The Tx, Rx and GND line must be connectedbetween the COMM Ports of the master and remote unit. If this parameter isdisabled the [SELECT] key will have no effect on the master indicator.P283.01 Prtut Enables or disables the use of the [PRINT] and [UNITS] keys on the masterindicator (350 I.S.). When this parameter is enabled and the keys are pressed, thePrint and Units keys will be simulated. The Tx, Rx and GND line must be connectedbetween the COMM Ports of the master and remote unit. If this parameter isdisabled the keys will have no effect on the master indicator.P284.01 Print Enables or disables the use of the [PRINT] key on the master indicator. When thisparameter is enabled and the key is pressed, a Print key command will berecognized by the master indicator. The Tx, Rx and GND line must be connectedbetween the COMM Ports of the master and remote unit. If this parameter isdisabled the [PRINT] key will have no effect on the master indicator.P285.01 Tare Enables or disables the use of the [TARE] key on the master indicator. When thisparameter is enabled and the key is pressed, a Tare key command will berecognized by the master indicator. The Tx, Rx and GND line must be connectedbetween the COMM Ports of the master and remote unit. If this parameter isdisabled the [TARE] key will have no effect on the master indicator.P286.01 Enter Enables or disables the use of the [ENTER] key on the master indicator. When thisparameter is enabled and the key is pressed, an Enter/Sample key command willbe recognized by the master indicator. The Tx, Rx and GND line must be connectedbetween the COMM Ports of the master and remote unit. If this parameter isdisabled the [ENTER] key will have no effect on the master indicator.Type / choices(*=Default)Enable* / DisableEnable* / DisableEnable* / DisableEnable* / DisableEnable* / DisableEnable* / DisableEnable* / DisableEnable* / DisableEnable* / Disable110Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!